Owner's Manual for CAPELLA models including: Energia B, Energia B Remote Controller, Remote Controller, Controller
Owner's manual. For the system model. Energia B. Page 2. Remote controller. 1. Operation instructions. Operation modes. 3. Airflow direction control. 4. SMART ...
optional. Used to enter fuzzy logic operation directly when the unit is on . When the Air conditioner and Remote controller are.
File Info : application/pdf, 14 Pages, 975.01KB
DocumentDocumentOwner's manual For the system model Energia B REMARQUE IMPORTANTE : Lisez attentivement ce manuel avant d'installer ou d'utiliser votre nouveau climatiseur. Veillez à conserver ce manuel pour référence ultérieure. Remote controller Instructions Remote controller 1 Operation instructions Operation modes 3 Airflow direction control 4 SMART mode 5 SUPER mode 7 QUIET mode 7 TIMER mode 8 ECO mode 8 IFEEL mode 9 DIMMER button 9 CLOCK button 9 SLEEP mode 10 8°C HEAT mode 10 HI-NANO mode 10 CLEAN mode 11 Power control mode 11 Remote controller 5 Remote controller The remote controller transmits signals to the system. 5 1 MODE Press this button to select the operation mode. 3 HI-NANO (optional) 2 Used to adjust the room temperature and the timer, also real time. Used to set or cancel HI-NANO operation. 6 SUPER Used to start or stop the fast cooling/heating. (Fast cooling operates at high fan speed with 2 16(61°F) set temp automatically ; Fast heating operates at auto fan speed with 30(86°F) set 1 temp automatically) 3 8 SLEEP Used to set or cancel Sleep Mode operation. 6 9 ECO 9 Used to set or cancel ECO Mode operation. 12 11 ON/OFF TIMER Used to set or cancel the timer operation. 12 SMART(optional) 13 Used to enter fuzzy logic operation directly when the unit is on . When the Air conditioner and Remote controller are in standby, and the mode of remote controller is in Cooling or Dry, press this button for about 5 seconds to enter the auto-clean mode and then the indicator " " will display on LCD . Press SMART or POWER or MODE button will escape from auto-clean mode, and then the indicator " " will disappeared(After the clean process finish, the air conditioner will return to Cooling or Dry as preset, while the indicator" " on remote controller will display for about 30 mins) 13 DIMMER/CLOCK 4 ON/OFF The appliance will be started when it is energized or will be stopped when it is 4 in operation, if you press this button. 5 FAN SPEED 5 Used to select fan speed in sequence auto, higher, high, medium, low and lower. 7 7 SWING 8 Used to stop or start vertical adjustment 10 louver swinging and set the desired up/ 11 down airflow direction. 14 10 SWING (optional) Used to stop or start Horizontal adjustment louver swinging and set the desired left/right airflow direction. 14 IFEEL/QUIET 19 + 2 ( ) 7 8 HEAT(optional) Used to start or stop 8 HEAT mode. Press to set IFEEL Mode operation. In IFEEL mode,the Air Conditioner operates basis temperature sensor fitted in remote instead of machine, Advice to use IFEEL mode and the remote put where the indoor unit receive signal easily.Press this button above 5 seconds,start or stop IFEEL mode. Used to set or cancel Quiet Mode operation. When you press this button, all the display of indoor unit will be closed. Press any button to resume display. Used to set the current time. Indication symbols on LCD: Cooling indicator Auto Auto fan speed Lower fan speed IFEEL Auto-clean indicator Swing (up/down) indicator Dry indicator Fan only indicator Heating indicator Higher fan speed High fan speed Medium fan speed Quiet indicator Economy indicator Super indicator Display temperature Display Power control Display set timer Display current time Swing (left/right) indicator Signal indicator SMART Smart indicator Low fan speed Sleep indicator 8 Heat indicator HI-NANO indicator Note: Each mode and relevant function will be further specified in following pages. 1 Remote controller Remote controller How to Insert the Batteries 1. Pry open the battery cover according to the arrow direction. 2. Insert new batteries making sure that the (+) and (-) of battery are matched correctly. 3. Reattach the cover by pressing it back into position. 1 2 3 Note: Use 2 LR03 AAA(1.5volt) batteries. Do not use rechargeable batteries. Replace batteries with new ones of the same type when the display becomes dim. Storage and Tips for Using the Remote Controller The remote controller may be stored mounted on a wall with a holder. Note: The remote controller holder is an optional part. Note: The shape may differ from that of the remote controller holder you have selected. remote controller holder fixing. remote controller mounting. How to Use To operate the room air conditioner, aim the remote controller to the signal receptor.The remote controller will operate the air conditioner at a distance of up to 7m when pointing at signal receptor of indoor unit. CAUTIONS For appropriate signal transmission between remote controller and indoor unit, keep the signal receiver away from the following items: Direct sunlight or other strong lights or heat Flat panel television screen or other electrical appliances that react to the remote controller Additionally, the air conditioner will not operate if curtains, doors or other materials block the signals from the remote controller to the indoor unit. If the signal may not be transmitted properly, either move these materials or consult your local dealer. 2 Signal receptor Operation instructions Operation modes Selecting mode Press Result : button once by once The operation modes changed in sequence: PRESS COOLING DRY FAN ONLY HEATING FANONLY Heating mode is NOT available for cooling only air conditioner. FAN mode Press Result : button once by once The fan speed is changed in sequence: Auto FANONLY Auto Higher High Medium Low Lower PRESS At "FAN ONLY" mode, only "Auto" is not available. At "DRY" mode, Fan speed is set at "AUTO" automatically, "FAN SPEED" button is ineffective in this case. Some models, such as commercial air conditioner products, only have the third gear speed. Auto Auto High High Medium Low Low FANONLY Setting temperature Press button once Result : Raise temperature setting by 1 or 1°F Press button once Result : Lower temperature setting by 1 or 1°F Range of available set temperature *HEATING, COOLING 16~30(61°F~86°F) DRY ±7 deg C FAN ONLY unable to set *Note: Press and hold " " button and " " button together for 2 seconds will alternate the temperature display between the and °F scale. *Note: Heating mode is NOT available for cooling only models. *Note: At "Dry" mode, a decrease or rise of up to 7 can be set with Remote controller if you still feel uncomfortable. 3 Operation instructions Turning on Press button. Result : The RUN indicator of the indoor unit lights up. SWING , SMART , SUPER , QUIET, TIMER , ECONOMY , IFEEL , DIMMER , CLOCK , SLEEP and 8 HEAT operation modes will be specified in the following pages. Changing modes during operation, sometimes the unit does not response at once. Wait 3 minutes. During heating operation, air flow is not discharged at the beginning. After 25 minutes, the air flow will be discharged until temperature of indoor heat exchanger rises. Wait 3 minutes before restarting the appliance. Airflow direction control Vertical airflow(Horizontal airflow) is automatically adjusted to a certain angle in accordance with the operation mode after turning on the unit. PRESS Operation mode Direction of airflow COOLING, DRY horizontal *HEATING, downward FAN ONLY PRESS The direction of airflow can be also adjusted to your own requirement by pressing the " the remote controller. *Heating mode is only available for heat pump models. " buttons of Vertical airflow control (with the remote controller) Using remote controller to set various angles of flow or specific angle as you like. 1Press " " button once. Result : The vertical adjustment louver will swing up and down automatically. PRESS 2Press and hold " " button for about 5s (invalid for some models). Result : The vertical adjustment louver will swing up and down automatically at a smaller angle. Press " " button again . Result : The louvers swing to a suitable angle as desired PRESS Horizontal airflow control (with the remote controller) Using remote controller to set various angles of flow or specific angle as you like. Press " " button once. Result : The horizontal adjustment louver will swing left and right automatically. PRESS 4 Operation instructions Press " Result : " button again . The louvers swing to a suitable angle as desired. NOTE:If the unit doesn't have four ways airflow function, you can adjust PRESS horizontal airflow by yourself.(invalid for some models) A Do not turn the vertical adjustment louvers manually, otherwise malfunction may occur. If that happens, turn off the unit first and cut off the power supply, then restore power supply again. B It is better not to let the vertical adjustment louver tilt downward for a long time at COOLING or DRY mode to prevent condensed water from dripping. SMART mode(invalid for multi system) In this mode, it can automatically adjust the operation mode, temperature, wind speed, wind direction, etc. according to the ambient temperature of the room to ensure that customers get the most comfortable experience. How to set SMART mode? Press the Result : button. Enters SMART mode(fuzzy logic operation) directly only when the unit is on . Temperature and fan speed are automatically PRESS set based on theactual room temperature. For the split-type models, such as wall-mounted air conditioners and some floor-standing air conditioners, their operation mode and set temperature should be determined based on the indoor temperature. Operation mode and temperature are determined by indoor temperature Heat pump models Indoor temperature Operation mode Target temperature 21(70°F) or below 21-23(70°F-73°F) 23-26(73°F-79°F) Over 26(79°F) HEATING FAN ONLY DRY COOLING 22(72°F) Room temperature decrease 2(2°F) after operate for 3 minutes 26(79°F) Cooling only models Indoor temperature 23(73°F) or below 23-26(73°F-79°F) Over 26(79°F) Operation mode FAN ONLY DRY COOLING Target temperature Room temperature decrease 2(2°F) after operate for 3 minutes 26(79°F) For commercial air conditioner products, such as cassette type air conditioners, duct type air conditioners, ceiling & floor air conditioners and some floor-standing air conditioners, their operation mode should be determined based on the difference between the indoor temperature and set temperature. 5 Operation instructions The operation mode is determined by the difference between the indoor temperature and set temperature. Heat pump models Indoor temperature Operation mode Target temperature Below T-3(3°F) HEATING T T-3T indoor T+3(3°F) FAN ONLY T Over T+3(3°F) COOLING T Cooling only models Indoor temperature T+3(3°F) or below Over T+3(3°F) Operation mode FAN ONLY COOLING Target temperature T T SMART button is ineffective in SUPER mode. ECO button is ineffective in SMART mode. Press MODE button cancel SMART mode. Note: Temperature, airflow and direction are controlled automatically in SMART mode. However, For the on/off, you can choose from -2 to 2 (for some models you can choose from -7 to 7), for the inverter you can choose from -7 to 7. if you still feel uncomfortable. What you can do in SMART mode? Your feeling Uncomfortable because of unsuitable air flow volume. Button Uncomfortable because of unsuitable flow direction. Adjust Indoor fan speed alternates among Auto, Higher, High, Medium, Low and Lower each time this button is pressed. Press it once, the vertical adjustment louver(horizontal adjustment louver) swings to change vertical airflow direction(horizontal airflow direction). Press it again, swings stops. How to cancel the SMART mode? Press the Result : button. The SMART mode will be cancelled. PRESS 6 Operation instructions SUPER mode SUPER mode is used to start or stop fast cooling or heating only when the unit is on. SUPER mode can be set when the appliance is in operation or energized. In SUPER mode, you can set temperature, airflow direction or timer How to set SUPER mode? Press Result : button at the cool, dry and fan only mode. At high fan speed ,the set temperature automatically to 16(61°F). PRESS Press Result : button at the heat mode. At auto fan speed ,the set temperature automatically to 30(86°F). PRESS How to cancel SUPER mode? Press SUPER , MODE, FAN SPEED, ON/OFF, QUIET or SLEEP button. Result : The display return to the original mode. Escape from SUPER mode. Cancel Note: SMART button is not available in SUPER mode. ECO button is not available in SUPER mode. Press and hold the SUPER button for about 5 seconds will transmit the filter clean reset code (invalid for some models) QUIET mode In this mode, the air conditioner will work with low noise performance by low compressor frequency and low fan speed. This mode is only available for inverter models. PRESS Note: Press MODE, FAN SPEED, SMART, SUPER, ECO, QUIET or ON/OFF button cancel QUIET mode. 7 Operation instructions TIMER mode It is convenient to set the timer on with ON TIMER buttons when you go out in the morning to achieve a comfortable room temperature at the time you get home. You can also set timer off at night to enjoy a good sleep. How to set ON TIMER ? 1. Press Result : button. "12:00 ON" flashes on the LCD. PRESS Press the or button. Result : Once to increase or decrease the time setting by 1 minute. PRESS One and a half seconds to increase or decrease the time setting by 10 minute. For a longer time to increase or decrease the time by 1 hour. 3.When your desired time displayed on LCD, press the ON TIMER button and confirm it. Result : A "beep" can be heard. "ON" stops flashing. The TIMER indicator on the indoor unit lights up.(invalid for some models) PRESS 4. After the set timer displayed for 5 seconds the clock will be displayed on the LCD of the remote controller instead of set timer. How to cancel ON TIMER ? Press the button. Result : A "beep" can be heard and the indicator disappears, the time on mode has been canceled. PRESS Note: It is similar to set OFF TIMER , you can make the appliance switch off automatically at your desired time, the difference is you need to press the ON/OFF TIMER button for about 5 seconds to start or cancel the OFF TIMER. ECO mode In this mode, the air conditioner will bring you energy saving performance by lower running currency. ECO button is ineffective in SUPER and SMART mode. Press ON/OFF, MODE, , , FAN SPEED, SLEEP, QUIET button cancel ECO mode. Press and hold " QUIET " button and "ECO" button together for 3 seconds PRESS will alternate the mode between the cooling only and the cooling and heating. 8 Operation instructions IFEEL mode The temperature sensor built in remote controller is activated.It can sense its surrounding temperature,and transmit the signal back the unit,the unit can adjust the temperature so as to provide maximum comfort. How to set IFEEL mode ? Press the button for about 5 seconds once. Result : The transmit signal in the display will appear, the IFEEL function will be started. O Note: PRESS The default setting is IFEEL inactiving. How to cancel IFEEL mode? Press the button for about 5 seconds once again. Result : IFEEL function will be shunted off. PRESS DIMMER button How to set the DIMMER ? Press the DIMMER button to turn off the light and the display in the unit. Note: When the light is off, receive signal will turn on the light again. O PRESS CLOCK button How to adjust the real time? 1. Press button for about 5 seconds once. Result : The time flashes on the LCD. O PRESS 2. Press Result : and buttons. Once to increase or decrease the time setting by 1 minute. One and a half seconds to increase or decrease the time setting by 10 minute. For a longer time to increase or decrease the time by 1 hour. 3. Press Result : button once again. The real time is set. PRESS 9 PRESS O Operation instructions SLEEP mode SLEEP mode can be set in COOLING ,HEATING or DRYING mode. This function gives you a more comfortable environment for sleep. The appliance will stop operation automatically after operating for 8 hours. Fan speed is automatically set at low speed. How to set SLEEP mode ? Each time button is pressed. Result : SLEEP function will be started. O PRESS SLEEP mode : Set temperature will rise by 2(2°F) at most if the appliance operates in cooling mode for 2 hours constantly, then keeps steady. Set temperature will decrease by 2(2°F) at most if the appliance operates in heating mode for 2 hours constantly, then keeps steady. Note: In cooling mode, if room temperature is 26(79°F) or above, set temperature will not change. Note: Sleep mode is NOT available for Smart and Fan only mode. Note: Heating is NOT available for cooling only air conditioner. How to cancel SLEEP mode ? Press SUPER , SMART, MODE, SLEEP, ON/OFF, ECO or FAN SPEED button Result : The display return to the original mode. O Escape from SLEEP mode. PRESS 8 HEAT mode(optional) How to set 8 HEAT ? In HEATING mode, Press and buttons together for 3 seconds to start 8 HEAT mode. In 8°C HEAT mode, the fan speed is set at "AUTO" automatically.The icon will appear on the LCD. If pressing any button, other than ON/OFF TIMER, CLOCK, DIMMER, IFEEL and SWING, 8°C HEAT function will be turned 1 off. And the icon will disappear. O Note : Press together In 8°C HEAT mode, the default temperature is set 8. for 3 seconds 2 8°C HEAT mode can be set only when the air conditioner works in HEATING mode. HI-NANO mode (optional) When the Remote controller is on, in any mode, press HI-NANO button can set or cancel the HI-NANO mode, then the icon " " will appear or disappear on the LCD O PRESS 10 Operation instructions CLEAN mode(optional) When the air conditioner and remote controller are in standby, and the mode of remote controller is in Cooling or Dry, press" " button for 5 seconds once to start Clean mode,then the indicator " " will display on LCD. Press ON/OFF or SMART or MODE button can cancel the Clean mode, then the indicator " " will disappear. PRESS After the clean process finish, the air conditioner will return to Cooling or Dry as preset, while the indicator" " on remote controller will display for about 30 mins Power control mode(optional) When in Cooling mode press button for about 5 seconds once to start Power control mode ( fan will run in low speed ), press this button for about 5 seconds once again to stop it. When the appliance in the Power control mode, press button once by once Result : The operation modes changed in sequence: P 75% 55% 35% PRESS Power control mode is ineffective in SUPER or ECO mode. Except for the button of Swing, Dimmer, Ifeel, Timer , Fan, press the other buttons can exit the Power control mode, and the indicator " % " will disappear. When start the Power control mode, the fan will automatically enter low wind speed, but you can change the wind speed by press the Fan button. 11 The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details. Any updates to the manual will be uploaded to the service website, please check for the latest version.