Company Information
Softing Industrial Automation GmbH
Richard-Reitzner-Allee 6
D-85540 Haar
Tel.: +49 89 4 56 56-340
Fax: +49 89 4 56 56-488
Email: info.automation@softing.com
Website: https://industrial.softing.com
Product and Component Versions
Product | Deliverable | Version | Date |
---|---|---|---|
edgeGate | V1.04 | 28.07.2025 | |
edgeConnector | edgeconnector_v2025.03_arm_v7.tar.gz | V2025.03 | 21.07.2025 |
adminUI (app) | adminUI-Install_V1.20-ARM64.tar.gz | V1.20 | 28.07.2025 |
adminUI (conf) | admin-edge-gate-V1.04.json | V1.04 | 28.07.2025 |
tshark | tshark_DockerImage_V2025.07-ARM64.tar.gz | V2025.07 | 01.07.2025 |
Components:
- tshark: V2025.07
- adminUI: V1.20
- licenseServer: V4.65
- edgeConnector: V2025.03
1. New or enhanced features
- S7: Driver general improvements.
- S7: New data types: Timer, S5-Tim, and Counter as human readable format
- S7: New data types: LInt, ULInt, SUInt, and LReal
- FANUC: Enable PMC & Macros write functionality
- FANUC: Enable PMacros area (RW)
- SINUMERIK 840D: Enable Writing functionality
- Disable usage of TLS1.0 and TLS1.1 on HTTPS interface
2. Removed features
- HTTP access to edgeConnector.
3. Fixed issues
- DF 1373: Error when press X to check Status of disabled mapped
- DF 1021: Failed to upload large SDFI file
- DF 1335: No default awl file nor default SDFI file in docker image edgeconnector
- DF 1192: [GUI] Add scroll bar for both lists in standard/mapped Address space Destinations
- DF 1316: RefreshConnectionsLive does not work if not click before OPC UA Client Application Settings page to set SGUI.ClientActivate
- DF 1317: Incorrect Enabled state after disabled PLC connection for Sinumerik
- DF 1326: Admin is part of the OPC UA group
- DF 1348: MQTT Subscriber does not release the address space sight name correctly
- DF 1346: Saving endpoint with new certificate edited is not working properly
- DF 1065: edgeconnector-UI Restart pop-up window truncated buttons
- DF 1321: Cannot download all files in user certificates
- DF 1329: License Overview page is refreshed every 5 seconds even though we have no change in license details.
- DF 1356: edgeConnector Fanuc Crashes When Importing PMC File with Missing Variable Names
- DF 1371: Crash when connection to s7-1500 breaks
- DF 1367: Adding PLC connection with "localhost" address crashes the application
- DF 1369: Modifying "TCP Port" number in Advanced Settings for an Allen Bradley or Siemens S7-72 active connection crashes the application
- DF 1370: Modifying some advanced connection parameters for AB connection crashes the application
- DF 1381: Incorrect message at change username and change groups
4. Known issues
- CVE-2022-49043: [DF-1320]: - xmlXIncludeAddNode
- CVE-2025-49794, CVE-2025-49796: [DF-1382]: Vulnerability found in libxml2 by trivy
- DF 747: Missing routing on aggregator from /runtime/core/metrics to /metrics
- DF 800: Old and new style authentication do not forcefully log out each other
- DF 811: The REST call for system restart should not be returned before the system restart is initiated
- DF 1256: Browse calls on node Ids with large number of references provide faulty results in different scenarios
- DF 1265: Internal error while adding a note to a mapped address space
- DF 1272: Add valuable text to the address Space Overview at Status good.
- DF 1277: OPC UA Standard Nodeset is not correctly displayed when missing (uploaded AS version higher than loaded one)
- DF 1280: Incorrect error message displayed for an AS that already exists
- DF 1303: Wrong message tooltip at enabled connection icon in Status halted
- DF 1307: Required flag missing from the used companion specs in the mapped address space wizard
- DF-1310: The connection test displays wrong error message
- DF-1318: Unable to Connect to OPC UA Server of S7 1500 with Encrypted Communication under certain scenarios
- DF-1319: The Show EP EndpointDescriptions functionality doesn't work as expected
- DF-1337: License details table updated with long delay after License Server is stopped
- DF-1384: edgeconnector Fanuc: OPCUA Server shall handle/enforce the node permissions