User Manual for HASWILL ELECTRONICS models including: HDL-W116-10T, W116 Panel Temperature Data Logger with Bluetooth, W116 Panel Temperature Data Logger, Panel Temperature Data Logger, Temperature Data Logger, Data Logger, Logger, W116

W116 Bluetooth Temperature Data Logger Insutruction

W115 is a temperature data logger with built-in lithium battery and blue tooth connect.

Haswill Electronics

W116 Panel Temperaturdatenlogger mit Bluetooth Bedienungsanleitung

W116 Panel Temperaturdatenlogger mit BlueTooth – Haswill Electronics

W116 Bluetooth Temperature Data Logger Insutruction

Title: W116 Bluetooth Temperature Data Logger Insutruction Author: Haswill Electronics Subject: W115 is a temperature data logger with built-in lithium battery and blue tooth connect.

PDF preview unavailable. Download the PDF instead.

User-Manual-of-W116-panel-temperature-data-logger-with-bluetooth-A4
W116 Panel Temperature Data Logger with Bluetooth
(HDL-W116-10T)
User Manual
Type-C

Overview W116 series are panel temperature data loggers which supports Bluetooth connection (ESC protocol), monitor and record the temperature data of food, medicine, chemical supplies, and other objects during storage and transportation.
Dimension & Weight Whole99.4 * 70.2 * 11.4 mm (W*H*T) Front Panel99.4 * 70.2 * 2 mm (W*H*T) Back Panel82.5 * 48.5 * 9.4 mm (W*H*T) Net weight: 65 gsm
Buttons and Operation Method There are 3 buttons on the right of the front panel. Mainly exist two actions: 1. Short Press: Press the button and release at once. 2. Long Press: hold down the button for 4 seconds.

Short Press Short Press Short Press Long Press Long Press Long Press

Next Menu Previous Menu Print a strip Start the records Stop the rocords Print the records

Short Press Long Press

+

Lock/Unlock the keys

+

Wipe All Data (ensure stop

recording firstly)

1

Power Built-in Li-ion Battery, the type C interface is used for charging and data transmission.
Power on/off [Power on] Plug it into a type-C charger; [Power off] Unplug the type-c charger, make sure the buttons are not locked, and then press and hold all the buttons for 4s to shut down. Enable Recording Long press the button to active the recording, the screen will shows if successful
Disable Recording Long press the button to stop the recording, the screen will shows if successful
Select A Trip From Trips List Short press the button, the screen will shows , which means all trips; Now you can press the key (Next) or the key (Previous) to select one trip;
Print One Trip's Data Long press the button to print one trip's data, the screen will shows , which means it will print soon. Tip: it will print the latest trip if you did not select it.
Output Data And Generate Reports Connect this device to a computer by a type C cable, and you will find a U-Disk where storage all data and reports, more options are available with the help of the accompanying software.
2

LCD Diagram

3

8

6

2

7

9

1

5

10

4

16

15

17 11
14

12

13

1 Temperature display interface 10 Keys lock icon

2 Date display interface

11 No alarm icon

3 Time display interface

12 Over limit icon

4 Upper limit display interface 13 Record status icon

5 Lower limit display interface 14 USB connection status icon

6 Record points display interface 15 Non-recording status icon

Lowest temperature record 7 display interface

16 Temperature unit

8 Highest temperature record display interface

17 Bluetooth identifier

9 Battery level

3

LCD Menu
1 Real Time Temp

2 Date

3 Time

4 Recordable Temp. Upper Limit

5 Recordable Temp. Lower Limit

6 Records Count

7 Highest Temp. in Records

8 Lowest Temp.in Records
4

Battery Level Instruction

Battery level

Remaining capacity
60% ~ 100%

20% ~ 60%

10% ~ 20%

< 10%

Note: 1 When the remaining battery capacity is less than 20%, it is
recommended to replace the battery to prevent inconvenience; 2 When the remaining battery capacity is less than 10%, please
replace the battery as soon as possible to prevent the battery from running out.
Packing List
1 piece of panel data logger with Built-in Li-ion Battery 1 piece of UIFuser manual 1 piece of eg: MHT-P16 Bluetooth Printer (Optional)
The data logger has a built-in expandable list of printer names and automatically connects to the printers in the list via the Bluetooth "ESC" protocol. With the help of the developer, additional bluetooth printers can be supported by upgrading the list of printer names.
5

Factory Default Parameters

Temperature unit: °C

Export file type: PDF

Time zone: UTC +8:00

Report language: English

Start mode: start by pressing key

Start delay: 0 min

Stop mode: stop by pressing key

Temperature offset value: ±0.0°C

Temperature upper limit: W116B:70.0°C; W116C:100°C

Temperature lower limit: W116B: -40.0°C; W116C:-200°C

Normal record interval: 1min

Overlimit record interval: 30s

Circular log: enabled

Multiple start: enabled

Long press keys to delete data: enabled

Reset record after finishing configuration: disabled

LCD always on: timing off

Alarm setting: no alarm

Trip No.: XC000000

Trip description: NULL

* Long press:hold the key for no less than 4s.