Instruction Manual for BACA SYSTEMS models including: Robo SawJet M Series Mitering Robotic SawJet, Robo SawJet M Series, Mitering Robotic SawJet, Robotic SawJet, SawJet

RSJM Single Table Layout Rev L-1.02

BACA\mneto (DESKTOP-VSK9M1T)

View Single Table Layouts

Robo SawJet M Series | Mitering Robotic SawJet | BACA Systems

PDF preview unavailable. Download the PDF instead.

RSJM-Single-Table-Layout-Rev-L-1.02
8

7

6

5

4

3

2

1

Electrical Panel Clearance
D
3'-0"
C
Required Space for Pump
Maintenance 3'-0" Front
& Sides
B

Minimum Required Space for Installing Fence 8"

7'-2" SQ. CL
Foundation Cutout

Camera Optional

CL

*Flexible PC Placement

8"

8'-9

1 4

"

18'-6

1 2

"

21'-2"

9'-9

1 4

"

RSJM Single Pocket D
Left Table & Utilities

System Dimension: 20'-7" x 18'-612"
Overall Footprint (incl. utilities & clearance): 28'-5" x 21'-2"

Utility Requirements

C

Power:
1 Circuit 480V 3Phase 80A (65 FLA) (Robot) 1 Circuit 480V 3Phase 100A (63 FLA) (Pump)

Air:
5 CFM @ 85-100 PSI Range (Robot) 3 CFM @ 60-100 PSI Range (Garnet Hopper)

Water:

1 Source Clean

B

1 Port 4gpm (Waterjet)

1 Port 3-5gpm <65°F (Pump Cooling Water)

1 Source Gray 5gpm (Saw Water)

15'-9"

4'-10"

28'-5"

20'-7"

See Pre-Install Document For Additional Information

A

A

FINAL PLACEMENT DETERMINED DURING INSTALLATION. DO NOT SCALE

8

7

6

5

4

3

PROPRIETARY AND CONFIDENTIAL. DRAWN BY: MN

CHECKED BY: RK

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF

RSJM Single Table Layout - Pocket, Left Utilities

BACA SYSTEMS.

ANY REPRODUCTION IN PART OR AS A

Job No: -----

WHOLE WITHOUT THE WRITTEN PERMISSION

OF BACA SYSTEMS IS PROHIBITED.

SIZE: B SCALE 1:45

REV: L-1.02 1/4/2024

SHEET 1 OF 6

2

1

8

7

6

5

4

3

2

1

Minimum Required Space for Installing Fence

D

8"

8"

Electrical Panel Clearance 3'-0"

RSJM Single Pocket D
Right Table & Utilities

8'-9

1 4

"

C

21'-2"

18'-6

1 2

"

9'-9

1 4

"

B

7'-2" SQ.
CL

Foundation Cutout
CL

Camera Optional

*Flexible PC Placement

Required Space for Pump
Maintenance
3'-0" Front & Sides

System Dimension: 20'-7" x 18'-612"
Overall Footprint (incl. utilities & clearance): 28'-5" x 21'-2"

Utility Requirements

C

Power:
1 Circuit 480V 3Phase 80A (65 FLA) (Robot) 1 Circuit 480V 3Phase 100A (63 FLA) (Pump)

Air:
5 CFM @ 85-100 PSI Range (Robot) 3 CFM @ 60-100 PSI Range (Garnet Hopper)

Water:

1 Source Clean

B

1 Port 4gpm (Waterjet)

1 Port 3-5gpm <65°F (Pump Cooling Water)

1 Source Gray 5gpm (Saw Water)

4'-10"

15'-9"

20'-7"

28'-5"
A

See Pre-Install Document For Additional Information
A

FINAL PLACEMENT DETERMINED DURING INSTALLATION. DO NOT SCALE

8

7

6

5

4

3

PROPRIETARY AND CONFIDENTIAL. DRAWN BY: MN

CHECKED BY: RK

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF

RSJM Single Table Layout - Pocket, Right Utilities

BACA SYSTEMS.

ANY REPRODUCTION IN PART OR AS A

Job No: -----

WHOLE WITHOUT THE WRITTEN PERMISSION

OF BACA SYSTEMS IS PROHIBITED.

SIZE: B SCALE 1:45

REV: L-1.02 1/4/2024

SHEET 2 OF 6

2

1

8

D
Electrical Panel Clearance 3'-0"

C

Required Space for Pump
Maintenance

3'-0" Front & Sides

B

7

6

5

4

3

2

1

26'-5

1 2

"

8'-9

1 4

"

18'-6

1 2

"

9'-9

1 4

"

7'-2" SQ.

CL

Foundation Cutout

CL

Ceiling Camera Optional

Minimum Required Space

for Installing Fence RSJM Single End Load

D

8"

8"

Left Utilities

4'-10"

System Dimension: 21'-9" x 18'-612"
Overall Footprint (incl. utilities & clearance): 24'-414" x 26'-512"

Utility Requirements

C

Power:
1 Circuit 480V 3Phase 80A (65 FLA) (Robot) 1 Circuit 480V 3Phase 100A (63 FLA) (Pump)

21'-9"

24'-4

1 4

"

16'-11"

Air:
5 CFM @ 85-100 PSI Range (Robot) 3 CFM @ 60-100 PSI Range (Garnet Hopper)

Water:

1 Source Clean

B

1 Port 4gpm (Waterjet)

1 Port 3-5gpm <65°F (Pump Cooling Water)

1 Source Gray 5gpm (Saw Water)

*Flexible PC Placement
A

See Pre-Install Document For Additional Information
A

FINAL PLACEMENT DETERMINED DURING INSTALLATION. DO NOT SCALE

8

7

6

5

4

3

PROPRIETARY AND CONFIDENTIAL. DRAWN BY: MN

CHECKED BY: RK

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF

RSJM Single Table Layout - End Load, Left Utilities

BACA SYSTEMS.

ANY REPRODUCTION IN PART OR AS A

Job No: -----

WHOLE WITHOUT THE WRITTEN PERMISSION

OF BACA SYSTEMS IS PROHIBITED.

SIZE: B SCALE 1:45

REV: L-1.02 1/4/2024

SHEET 3 OF 6

2

1

8

Minimum Required

Space for

D

Installing Fence

8"

8"

4'-10"
C

24'-4

1 4

"

21'-9"

16'-11"

B

7

6

5

9'-9

1 4

"

18'-6

1 2

"

26'-5

1 2

"

8'-9

1 4

"

CL

7'-2" SQ.

Foundation Cutout

CL

Ceiling Camera Optional

4

3

2

1

RSJM Single End Load D

Right Utilities

Electrical Panel

Clearance

3'-0"

System Dimension: 21'-9" x 18'-612"

Overall Footprint (incl. utilities & clearance): 24'-414" x 26'-512"

Utility Requirements

C

3'-0" Front & Sides

Required Space for Pump
Maintenance

Power:
1 Circuit 480V 3Phase 80A (65 FLA) (Robot) 1 Circuit 480V 3Phase 100A (63 FLA) (Pump)
Air:
5 CFM @ 85-100 PSI Range (Robot) 3 CFM @ 60-100 PSI Range (Garnet Hopper)

Water:

1 Source Clean

B

1 Port 4gpm (Waterjet)

1 Port 3-5gpm <65°F (Pump Cooling Water)

1 Source Gray 5gpm (Saw Water)

*Flexible PC Placement
A

See Pre-Install Document For Additional Information
A

FINAL PLACEMENT DETERMINED DURING INSTALLATION. DO NOT SCALE

8

7

6

5

4

3

PROPRIETARY AND CONFIDENTIAL. DRAWN BY: MN

CHECKED BY: RK

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF

RSJM Single Table Layout - End Load, Right Utilities

BACA SYSTEMS.

ANY REPRODUCTION IN PART OR AS A

Job No: -----

WHOLE WITHOUT THE WRITTEN PERMISSION

OF BACA SYSTEMS IS PROHIBITED.

SIZE: B SCALE 1:45

REV: L-1.02 1/4/2024

SHEET 4 OF 6

2

1

8 D

7

6

C

12'-1

1 2

"

11'-6

1 2

"

7'-5"

B

CAMERA POST

5

4

3

2

1 D

ROBOT

RSJM Single Table Layout

Elevation View

C

Required overhead clearance with cameras: 12'-2"
Required overhead clearance without cameras: 11'-7"

B

See Pre-Install Document For Additional Information

A

A

FINAL PLACEMENT DETERMINED DURING INSTALLATION. DO NOT SCALE

8

7

6

5

4

3

PROPRIETARY AND CONFIDENTIAL. DRAWN BY: MN

CHECKED BY: RK

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF

RSJM Single Table Layout - Elevation View

BACA SYSTEMS.

ANY REPRODUCTION IN PART OR AS A

Job No: -----

REV: L-1.02

WHOLE WITHOUT THE WRITTEN PERMISSION

OF BACA SYSTEMS IS PROHIBITED.

SIZE: B SCALE 1:40 1/4/2024

SHEET 5 OF 6

2

1

8

7

6

5

4

3

2

1

D

D

RSJM UTILITY REQUIREMENTS

1

5

KUKA

ELECTRICAL CABINET

Reference pages in the Robo SawJet M-Series Pre-Install Document

2

6

ROBOT

1 Airline [pg. 13]

2 Foundation [pg. 14]

Saw Water/Grey Water [pg. 12]

3

- Place saw water connection minimum 36" away

C

from any power supply

C

H2O JET PUMP

H2O JET PUMP
3 Power [pg. 8] - 1 Circuit 480V 3Phase 100A 60Hz
4 H2O Pump Clean Water [pg. 9]

4

KUKA ELECTRICAL CABINET

7

5 Robot Power [pg. 8]

- 1 Circuit 480V 3Phase 80A 60Hz

6 Ethernet [pg. 3] (Internet Connection - Hard Wired)

GARNET

B

HOPPER

GARNET HOPPER

B

7 Airline [pg. 13]

OPERATOR STAND

See Pre-Install Document For Additional Information

A

A

FINAL PLACEMENT DETERMINED DURING INSTALLATION. DO NOT SCALE

8

7

6

5

4

3

PROPRIETARY AND CONFIDENTIAL. DRAWN BY: MN

CHECKED BY: RK

THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF

RSJM Single Table Layout - Utility Hook Up Points

BACA SYSTEMS.

ANY REPRODUCTION IN PART OR AS A

Job No: -----

REV: L-1.02

WHOLE WITHOUT THE WRITTEN PERMISSION

OF BACA SYSTEMS IS PROHIBITED.

SIZE: B SCALE 1:40 1/4/2024

SHEET 6 OF 6

2

1


SOLIDWORKS PDF Publisher