User Manual for Pulsar models including: PSG2-12V5A Built In Buffer Power Supply, PSG2-12V5A, Built In Buffer Power Supply, In Buffer Power Supply, Buffer Power Supply, Power Supply

PSG2 I k k EN v1.0

Wprowadzono, zmianę:, 17.08.2021, /, W, Instrukcji, PL/EN, wprowadził, zmiany:, Artur, Z.

Agata Dziurdzia

Stáhnout

PSG2-12V5A Napájecí zdroj 13,8V/5A - ATIS KOUKAAM - JSME ZABEZPEÈENÍ

Prospekt pro PSG2-12V3A (v1.0)

PSG2-12V3A (PULSAR) - Zdroj 3A 13,8V

Prospekt pro PSG2-12V5A (v1.0)

PSG2-12V5A (PULSAR) - Zdroj 5A 13,8V


File Info : application/pdf, 2 Pages, 43.65KB

PDF preview unavailable. Download the PDF instead.

7976-psg2-xxvxa-prospekt-eng-1.0
Power supplies PSG2 series Buffer switched mode power supply

CODE: PSG2 v.1.0/I

EN

NAME: Enclosed buffer switch mode power supply unit Grade 2

Features:

· compliance with norm EN50131-6:2017

· START function of manual switch to battery power

in grade 1, 2 and II environment class

· LED optical indication

· compliance with norm EN60839-11:2013 in

· dynamic battery test

grade 1, 2 and II environment class

· battery circuit continuity control

· supply voltage ~200 - 240 V

· battery voltage control

· DC 13,8 V or 27,6 V uninterruptible power supply · battery charging and maintenance contro

· available versions with current efficiencies:

· EPS technical output indicating AC power loss ­ relay

13,8 V: 2A/3A/5A/7A/10A/20A

· APS technical output indicating battery failure ­ relay

27,6 V: 2A/3A/5A/10A

· battery output protection against short circuit and

· high efficiency (up to 89%)

reverse connection

· battery charging current jumper selectable

· protections:

· deep discharge battery protection (UVP)

· SCP short circuit protection

· optional equipment: set of external LED indicators:

· OLP overload protection

PKAZ168, mounting plate DIN2-4

· OVP overvoltage protection

· surge protection

· warranty ­ 2 years from production date

Description
The buffer power supply is designed in accordance with the requirements of the (I&HAS) EN50131-6:2017 and (KD) EN60839-11:2013 standard, grade 1, 2 and II environmental class. The power supplies units are intended for an uninterrupted supply of I&HAS and KD devices requiring stabilized voltage of 12 or 24 V DC (±15%).

DISPLAYING PARAMETERS OF THE POWER SUPPLY:

PSU's name

Output voltage

Output current max.

Charging current

PSG2-12V2A PSG2-12V3A PSG2-12V5A PSG2-12V7A PSG2-12V10A PSG2-12V20A PSG2-24V2A PSG2-24V3A PSG2-24V5A
PSG2-24V10A

13,8 V 13,8 V 13,8 V 13,8 V 13,8 V 13,8 V 27,6 V 27,6 V 27,6 V
27,6 V

2,5 A 3,5 A 5 A 7 A 10 A 20 A 2,5 A 3,5 A 5 A
10 A

0,5 / 1 A 0,5 / 1 A 1 / 2 A 1 / 2 A 1 / 4 A 2 / 4 / 8 A 0,5 / 1 A 0,5 / 1 A 1 / 2 A
1 / 2 / 4 A

Total current of the receivers + battery charging current mustn't cross maximum current of power supply.

Tel. +48-14-610-19-40, fax: +48-14- 610-19-50, www.pulsar.pl, www.zasilacze.pl, e-mail: sales@pulsar.pl

Power supplies PSG2 series Buffer switched mode power supply

TECHNICAL DATA
PSU type Power supply: Output voltage Current consumption by the PSU systems during battery-assisted operation: Battery circuit protection SCP and reverse polarity connection:
Overload protection OLP:
Overvoltage protection OVP:
Deep discharge battery protection UVP: Optical indication: LED optical indication output (intended for optional indication set PKAZ168): Operating conditions: Protection class PN-EN 62368-1: Degree of Protection PN-EN 60529: Operating temperature: Storage temperature: Operating temperature: Declarations, warranty : Optional equipment: Notes:

PSG2-12V

PSG2-24V

A (EPS - External Power Source), II environmental class

~ 200 - 240 V

11 - 13,8 V ­ buffer operation 10 - 13,8 V ­ battery-assisted
operation

22 - 27,6 V ­ buffer operation 20 - 27,6 V ­ battery-assisted
operation

30 - 50mA

20 - 40mA

FBAT fuse (in case of a failure, fuse-element replacement required)

105-150% PSU power, automatically recovered

>19 V (activation requires disconnecting the load or supply
for about approx. 1 min)

>37V (activation requires disconnecting the load or supply
for about approx. 1 min)

U<9,5 V (± 0,5V) ­ disconnection of battery terminal

U<19 V (± 0,5V) ­ disconnection of battery terminal

- LEDs on PCB of power supply unit
LED AC ­ presence of AC voltage LED DC ­ presence of DC voltage in the output of the PSU
APS FLT ­ battery failure
II environmental class (PN-EN12101-10:2007), -5oC ÷ 40oC
I (first)
IP20 -10ºC...+40ºC -20ºC...+60ºC PN-83/T-42106 CE, 2 years from the production date a set for optical indication LED PKAZ168, mounting plate DIN3-4 Cooling: convectional / orced

Tel. +48-14-610-19-40, fax: +48-14- 610-19-50, www.pulsar.pl, www.zasilacze.pl, e-mail: sales@pulsar.pl



References