User Manual for Pulsar models including: PSG2-12V5A Built In Buffer Power Supply, PSG2-12V5A, Built In Buffer Power Supply, In Buffer Power Supply, Buffer Power Supply, Power Supply
PSG2-12V5A Napájecí zdroj 13,8V/5A - ATIS KOUKAAM - JSME ZABEZPEÈENÍ
PSG2-12V3A (PULSAR) - Zdroj 3A 13,8V
PSG2-12V5A (PULSAR) - Zdroj 5A 13,8V
File Info : application/pdf, 2 Pages, 43.65KB
DocumentDocumentPower supplies PSG2 series Buffer switched mode power supply CODE: PSG2 v.1.0/I EN NAME: Enclosed buffer switch mode power supply unit Grade 2 Features: · compliance with norm EN50131-6:2017 · START function of manual switch to battery power in grade 1, 2 and II environment class · LED optical indication · compliance with norm EN60839-11:2013 in · dynamic battery test grade 1, 2 and II environment class · battery circuit continuity control · supply voltage ~200 - 240 V · battery voltage control · DC 13,8 V or 27,6 V uninterruptible power supply · battery charging and maintenance contro · available versions with current efficiencies: · EPS technical output indicating AC power loss relay 13,8 V: 2A/3A/5A/7A/10A/20A · APS technical output indicating battery failure relay 27,6 V: 2A/3A/5A/10A · battery output protection against short circuit and · high efficiency (up to 89%) reverse connection · battery charging current jumper selectable · protections: · deep discharge battery protection (UVP) · SCP short circuit protection · optional equipment: set of external LED indicators: · OLP overload protection PKAZ168, mounting plate DIN2-4 · OVP overvoltage protection · surge protection · warranty 2 years from production date Description The buffer power supply is designed in accordance with the requirements of the (I&HAS) EN50131-6:2017 and (KD) EN60839-11:2013 standard, grade 1, 2 and II environmental class. The power supplies units are intended for an uninterrupted supply of I&HAS and KD devices requiring stabilized voltage of 12 or 24 V DC (±15%). DISPLAYING PARAMETERS OF THE POWER SUPPLY: PSU's name Output voltage Output current max. Charging current PSG2-12V2A PSG2-12V3A PSG2-12V5A PSG2-12V7A PSG2-12V10A PSG2-12V20A PSG2-24V2A PSG2-24V3A PSG2-24V5A PSG2-24V10A 13,8 V 13,8 V 13,8 V 13,8 V 13,8 V 13,8 V 27,6 V 27,6 V 27,6 V 27,6 V 2,5 A 3,5 A 5 A 7 A 10 A 20 A 2,5 A 3,5 A 5 A 10 A 0,5 / 1 A 0,5 / 1 A 1 / 2 A 1 / 2 A 1 / 4 A 2 / 4 / 8 A 0,5 / 1 A 0,5 / 1 A 1 / 2 A 1 / 2 / 4 A Total current of the receivers + battery charging current mustn't cross maximum current of power supply. Tel. +48-14-610-19-40, fax: +48-14- 610-19-50, www.pulsar.pl, www.zasilacze.pl, e-mail: sales@pulsar.pl Power supplies PSG2 series Buffer switched mode power supply TECHNICAL DATA PSU type Power supply: Output voltage Current consumption by the PSU systems during battery-assisted operation: Battery circuit protection SCP and reverse polarity connection: Overload protection OLP: Overvoltage protection OVP: Deep discharge battery protection UVP: Optical indication: LED optical indication output (intended for optional indication set PKAZ168): Operating conditions: Protection class PN-EN 62368-1: Degree of Protection PN-EN 60529: Operating temperature: Storage temperature: Operating temperature: Declarations, warranty : Optional equipment: Notes: PSG2-12V PSG2-24V A (EPS - External Power Source), II environmental class ~ 200 - 240 V 11 - 13,8 V buffer operation 10 - 13,8 V battery-assisted operation 22 - 27,6 V buffer operation 20 - 27,6 V battery-assisted operation 30 - 50mA 20 - 40mA FBAT fuse (in case of a failure, fuse-element replacement required) 105-150% PSU power, automatically recovered >19 V (activation requires disconnecting the load or supply for about approx. 1 min) >37V (activation requires disconnecting the load or supply for about approx. 1 min) U<9,5 V (± 0,5V) disconnection of battery terminal U<19 V (± 0,5V) disconnection of battery terminal - LEDs on PCB of power supply unit LED AC presence of AC voltage LED DC presence of DC voltage in the output of the PSU APS FLT battery failure II environmental class (PN-EN12101-10:2007), -5oC ÷ 40oC I (first) IP20 -10ºC...+40ºC -20ºC...+60ºC PN-83/T-42106 CE, 2 years from the production date a set for optical indication LED PKAZ168, mounting plate DIN3-4 Cooling: convectional / orced Tel. +48-14-610-19-40, fax: +48-14- 610-19-50, www.pulsar.pl, www.zasilacze.pl, e-mail: sales@pulsar.pl