Instruction Manual for COOLON models including: Plume 10 AC RGBW LED, 10 AC RGBW LED, AC RGBW LED, RGBW LED, LED
Plume 10 AC TW | Architectural | Coolon LED Lighting
File Info : application/pdf, 6 Pages, 2.08MB
DocumentDocumentPLUME 10 AC INSTALL ATION INSTRUCTIONS PROFILE DIMENSIONS With Ball Joint Mounting Bracket Ø60mm 142mm 134mm 14mm 50mm Ball Joint Mounting Bracket Rotation 131mm Supplied with mains leader + AU Australian Plug 0° 90° 90° 90° 90° 0° archsales@coolon.com.au aus. 1300 287 533 intl. +613 8681 3633 w w w.c o o l o n.c o m.a u All documentation is subject to change without notice. Refer to our website for the latest information. PLUME 10 AC INSTALLATION INSTRUCTIONS ATTENTION · Please observe / follow the instructions methodically. · Please ensure the units are handled with extreme care. · Do not remove product from packaging prematurely. Only remove from packaging when ready for installation. · Failure to observe installation instructions and handling will void warranty of the product. · Fittings must be installed by a licensed electrician. · Before installing, make sure the power supply is switched off or mains cable is disconnected. PACKAGING DIMENSIONS 260mm 290mm 90mm PACKAGED WEIGHT 1.3kg (contents can vary) Version 1.0 Page 2 WIRING DIAGRAMS CASAMBI INSTALLATION Plume not reccomended for Classic Casambi Networks CASAMBI MESH NETWORK Up to 249 Plumes in an evolution Casambi mesh network. NEW DALI INSTALLATION FROM DALI MASTER DALI Bus CBU-DCS Max total luminaires + input devices is the same for one DALI network (CBU-DCS not included) EXPAND EXISTING DALI INSTALLATION FROM DALI MASTER DALI Bus CBU-DCS Max total luminaires + input devices is the same for one DALI network (CBU-DCS not included) DMX INSTALLATION DMX as casambi scene trigger FROM DMX CONTROLLER DMX SceneDMXcas Up to 64 Plumes, limited by the DALI network. Up to 64 Plumes, minus the number of devices used in existing DALI installation. CASAMBI MESH NETWORK Up to 249 Plumes in an evolution Casambi mesh network. SceneDMXcas provides scene and intensity selection for up to 20 pre-defined Casambi scenes. The DMX Start Address for each SceneDMXcas is user selectable. SceneDMXcas can be configured with the Casambi app. SceneDMXcas requires an external 12 24VDC Class 2 power supply. Please refer to SceneDMXcas documentation for detailed instructions. archsales@coolon.com.au aus. 1300 287 533 intl. +613 8681 3633 w w w.c o o l o n.c o m.a u All documentation is subject to change without notice. Refer to our website for the latest information. PLUME 10 AC INSTALLATION INSTRUCTIONS Version 1.0 Page 3 PLUME 10 AC INSTALLATION INSTRUCTIONS SPOT VISOR ACCESSORY (Sold Separately) STEP 1 Align spot visor with Plume Spotlight. Spot visor can be mounted at 0° or 90°. 90° 0° STEP 2 Slide spot visor over spotlight body until the end stop is in contact. archsales@coolon.com.au aus. 1300 287 533 intl. +613 8681 3633 w w w.c o o l o n.c o m.a u All documentation is subject to change without notice. Refer to our website for the latest information. STEP 3 Insert screw with star washer and tighten with hex key (1.5Nm). 1.5Nm Version 1.0 Page 4 BALL JOINT MOUNTING BRACKET STEP 1 Pick up base plate and select 2 suitable screws, refer to the table below for details. 30 ±1 STEP 2 Pick up base cover and align with base plate. Slot must be parallel to base plate edge. Snap base cover onto base plate as shown. PLUME 10 AC INSTALLATION INSTRUCTIONS STEP 3 Move / rotate spotlight to desired position, hold tight and fasten adjustment screw (recommended torque 10Nm) 5.5mm SCREW TYPE Metric Machine Screw Self Tapping Screw THREAD SIZE M5 10g (4.8mm) SCREW HEAD WASHER Ø (MAX) Ø13.5mm SCREW HEAD WASHER HEIGHT (MAX) 6.5mm LENGTH Dependant on installation conditions. Requirement: centre of ball head must withstand a vertical load of 20N and torque of 2.5Nm Locate and install base plate on wall/surface. Ensure screws are fully secured. Base Plate Base Cover STEP 3 Loosen adjustment screw until bracket arms fit over the ball head stud. Screws (Not included) 4mm Allen Key archsales@coolon.com.au aus. 1300 287 533 intl. +613 8681 3633 w w w.c o o l o n.c o m.a u All documentation is subject to change without notice. Refer to our website for the latest information. 10Nm Version 1.0 Page 5 PLUME 10 AC RGBW INSTALLATION INSTRUCTIONS CASAMBI READY Casambi is designed specifically for lighting and allows the user to easily control / automate a space using their phone, tablet or wireless switch. For more information, please visit https://casambi.com/ For a range of switches please visit https://casambi.com/ecosystem/ and explore the options. For use with a tablet and smart phone, download the Casambi app and follow the easy to use instructions to pair with your luminaire. How to use Casambi for the first time https://youtu.be/H5DRQ2vCQDw How to create a basic scene https://youtu.be/RGXkXU_4r2A How to create an animation scene https://youtu.be/0RJ3Hvwvtpo archsales@coolon.com.au aus. 1300 287 533 intl. +613 8681 3633 w w w.c o o l o n.c o m.a u All documentation is subject to change without notice. Refer to our website for the latest information. Version 1.1 Page 6