User Guide for INTELLI-GRID models including: IG2-BM, IG2-BM High Powered Management with Bluetooth Monitor, High Powered Management with Bluetooth Monitor, Bluetooth Monitor, Monitor

HIGH POWERED MANAGEMENT WITH BLUETOOTH MONITOR

HIGH POWERED MANAGEMENT WITH BLUETOOTH ...

19 mar 2023 — NO. DEFINITION. DESCRIPTION. 1. Solar. To indicate solar charger is charging. 2. Invert. To indicate inverters is working.18 pagine

Projecta 2000W Mobile Power System with Bluetooth Monitor & 200Ah Lithium Battery | Projecta | My Generator


File Info : application/pdf, 18 Pages, 2.46MB

PDF preview unavailable. Download the PDF instead.

Projecta IG2-BM Instruction Manual
INTELLI-GRID 12V 2000W
HIGH POWERED MANAGEMENT WITH BLUETOOTH MONITOR
P/No IG2-BM

SYSTEM INTRODUCTION
IG2-BM is a high powered solution for mobile power featuring 2000W inverter/charger, MPPT solor controller, DCDC charger with an easy to read Bluetooth display
SYSTEM COMPONENTS
· An easy to read monitor with APP · 2KW Inverter/Charger with AC change over switch · 40Amp MPPT Solar controller · 30Amp DC-DC Charger · 200Ah Lithium Battery · Fuses Box
PAB ­ FRONT: 1150 x 370 x 214mm PAB ­ BACK
LB200-HD
FEATURES
INVERTER 2000W inverter with 120Amp charging. Grid Power Booster and AC transfer. AS/NZS 3001 ready. GRID POWER BOOSTER Grid Power Boost supports mains power with an inverter to compensate for weak shore power i.e. a generator. BATTERY MONITOR An intelligent and compact battery meter ideal for monitoring SOC% and general status. MULTIPLE CHARGING OPTIONS 30A DC to DC charging and 40A MPPT Solar charging for charging from Vehicle or when sun is shining. LITHIUM BATTERY An advanced and powerful 200Ah lithium battery perfectly matched to the Intelli-Grid system provides ample power for off-grid requirement
2

MONITOR INTRODUCTION
1 234 5 67

89

10 11 12

13 14

NO DEFINITION

DESCRIPTION

1 Solar

To indicate solar charger is charging

2 Invert

To indicate inverters is working

3 Bypass

To indicate Grid or generator is presenting

4 Charge

To indicate battery is charging

5 Overload alarm

To indicate when inverter is overloaded

6 Battery low voltage alarm

To indicate when inverter reach under-voltage

7 Over temperature alarm

To indicate when inverter is over-temperature

8 Load percentage

To indicate the percentage of actual load power against rated power of inverter installed

9 Inverter ON/OFF switch

To turn Inverter ON or OFF

10 Value information arear

LCD displaying value

11 LCD screen

12

Scroll down or confirm button

To scroll down to next item.Or.as function of confirmation of your selection and configuration. With long press for 3 secs.

13 Mute button

To mute or unmute the alarm

14 Battery SOC

To indicate battery state of charge

3

DISPLAY INFORMATION IN VALUE AREA

DISPLAY INFORMATION

Battery

V A

kW

AC Output

Hz V

A

kW

AC Input

Hz V

A

Solar

kW V

ITEM
Battery voltage Battery current AC output power AC output frequency AC output voltage AC output current AC Input power AC Input frequency AC Input voltage AC Input current PV power PV voltage

INVERTER WARNING CODES

CODE 001 002 003 004 005 006 007 008 009 010 011 012 013 014 015 020 022 023 024 025

DISPLAY U_BAT_OV U_BAT_LV U_BAT_LV_Fault OverLoad NTC_HS_Fault NTC_TX_Fault T_BAT_OT Fan_Fault ParConnect_Err ParComm_Err Par_ID_Conflict Par_ParaSet_Conflict Par_SyncTimeOut_Err ModeSet_Mismatch Par_OutputCircuit_Err Acin_OV ACin_OF Acin_LF Acin_PhaseErr U_Neu_2_GND_Err

DESCRIPTION Battery over-voltage warning Battery under-voltage warning Battery under-voltage protection Over-load Heat sink NTC failed Transformer NTC failed Battery over-temperature Fan error Parallel connection error Parallel CAN communication error Parallel ID conflict Parallel parameter setting conflict Parallel synchronization timeout Working mode setting mismatched Parallel output circuit error AC input over-voltage AC input over-frequency AC input under-frequency AC input phase error AC input voltage between Neutral and Ground error

4

INVERTER ERROR CODES

CODE 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116

DISPLAY U_Bus_OV U_Bus_LV U_Bus_HW_Pro PSU_Fault T_HS_OT T_TX_OT Sam_HD_Fault EEPROM_Fail Output_ShortCut Output_OverLoad CoolSys_Err U_BAT_Low_Deep U_INV_LV Instant_OC_Soft EPO Rly_Err

DESCRIPTION DC bus over-voltage DC bus under-voltage DC bus hardware under-voltage Auxiliary power error Heat sink over-temperature Transformer over-temperature Sampling fault EEPROM fault Output short circuit Output over-load Cool system failed Battery deep discharge Inverter output under-voltage Inverter output instant over-current Emergency stop Relay error

5

COMPONENT SPECIFICATIONS
INVCHR2 2000W 12V INVERTER/CHARGER
Perfect for powering the most demanding 240V appliances on the go this inverter/charger is ideal for operating on or off the grid. An RCD is included to ensure maximum safety for the unit and operator. The inverter / charger is fitted with Grid /Power boost which is great if the shore power or generator is weak.

SPECIFICATIONS PART NO 240V CHARGING CHARGE TYPE INPUT OUTPUT BATTERIES SUPPORTED TEMPERATURE COMPENSATION INVERTER INPUT OUTPUT FREQUENCY OUTPUT POWER GRID BOOST OUPUT AC TRANSFER OPERATING TEMPERATURE WEIGHT IP RATING
6

INVCHR2
5 Stage Automatic 240VAC, 50/60Hz 32A(MAX) 12V,120A GEL, AGM, WET, Lithium YES
12V (10.5V~17V) 220/230/240 VAC 50/60 Hz 2000W (4000W peak) 24Amps, Mains Supply + 8.3Amps Inverter <2msec -20°C ~ 65°C 17KG IP20

CONNECTION COMPARTMENT

SIGNAL TERMINAL

NO. LABEL

1

Bat Sample



2

Remote

3 Com MON

4 Com Sync

Relay1 5  (NO,C,NC)

Relay2 6
 (NO,C,NC)

7

S+



DEFINITION Battery temperature and voltage sample. A dry contact input for remote on/off, ignition could be connected. RS485 port for external monitor such as INVCHRD-BT. Communication with PROJECTA's LB-HD series lithium battery, which is able to synchronize lithium battery's charging and discharging strategy
Dry contact output control 1(NO,C,NC)
Dry contact output control 2(NO,C,NC)
Slave charger for starter battery

7

SC540 5 STAGE MPPT SOLAR CHARGER CONTROLLER WITH 100V INPUT
Get the most out of your solar array using these Maximum Power Point Tracking (MPPT) solar controllers increasing the charging output by up to 30% (compared to PWM Solar controllers).

SPECIFICATIONS PART NO BATTERY VOLTAGE MAXIMUM SOLAR VOLTAGE STANDBY CURRENT CHARGER TYPE INPUT CONTROL TYPE BATTERIES SUPPORTED TEMPERATURE COMPENSATION COMMUNICATION STORAGE TEMPERATURE HUMIDITY IP RATING WEIGHT COOLING

SC540 12/24/48V 100V 1mA 12V 5 Stage 100V MPPT GEL, AGM, WET, Lithium Yes RS485 -40°C ~ 70°C 5 - 95% IP31 1.4KG Convection

8

LABEL

DESFiIlNk-IsTcIOreNen

Definition

PV

+ -

BAT

+ -

EPO

NC

C

NO

RS485

CPonVnection Connection

t+erminal t-erminal

for for

PVCaornranyecPtoiosintivteerminal for PV array Positive PVCaornrnaeycNtieognatteivrme inal for PV array Negative

CBoAnTnection Connection

t+erminal t-erminal

for for

BatCteornynPeocstiitoivneterminal for BatCteornynNecetgioantivteerminal for

Battery Positive Battery Negative

EPO cEoNnPCtOacts, defined for reEmPoOtecoonn/toafcf.ts, defined for remote on/off.

C
OutputNdOry contacts.

Output dry contacts.

RS485

Connection terminal for RS485 communication.

CToenmnepc.tSioenntseorrminal fCoroRnnS4ec8t5iocnotmermmuinaiclaftoironb.attery temperature sensor.

Temp. Sensor Connection terminal foPr ibnadtteefirnyittieomn poef rTaetmurpe. sSeennssoor.r

Pin

Definition

PIN DEFINITION OF TEMPPSinE1NSOR

Battery Positive

PIN

DEFINITIOPNin2

Pin 1

Battery PoPsiitniv3e

Pin 2

Battery NePgiant4ive

Battery Negative Temperature sensor
Battery Negative

Pin 3

Temperature sensorPin definition of RS485 communication port

Pin 4

Battery NegPaintive

Pin1

Definition

Pin2
PIN DEFINITION OF RS485PiCnO3MMUNICATION PORT

RS485_A

PIN Pin 1 Pin 2

DEFINITIOPNin4
Pin5 Pin6 Pin7

RS485_B

Pin 3

RS485_A Pin8

Pin 4

Pin 5

Pin 6

RS485_B

Pin 7

Pin 8

2

9

PMDCS30 DC-DC 12V CHARGER
Smart DC to DC chargers specifically designed for Intelli-RV and Intelli-Grid.

SPECIFICATIONS PART NO CHARGER TYPE ALTERNATOR INPUT VOLTAGE OUTPUT BATTERIES SUPPORTED STORAGE TEMPERATURE OPERATING TEMPERATURE IP RATING WEIGHT COOLING SMART ALTERNATOR
CONVENTIONAL

PMDCS30 5 Stage 12-16V 12V, <30A GEL, AGM, WET, Lithium -40°C ~ 70°C -40°C ~ 70°C IP20 1.0KG Convection Turn on: 11.6V Turn off: 11.5V Turn on: 13.2V Turn off: 12.8V

10

CONNECTORS AND TERMINALS
1 6
2 7
3 4 5

Connectors and terminals guide

No. Print

PMDCS30

Remarks

Alternator Connects to positive of Alternator

Connects to positive battery post

1

BAT-

Connects to negative of Alternator

Connects to positive of motor battery post

Circuit colours and labelling
Red + Label "Aux+"
Black ­ Label "Aux-"

2

AUX BAT

Connects to positive of auxiliary battery

BAT-

Connects to negative and negative of auxiliary battery

3 COM

For communication of RS485

Not Connected

Red + Label "Vehicle Batt+"
Black ­ Label "Vehicle Batt-"

1 2 4 3 4

Not used Set on for 30Amp, off for 15Amps
Used to set battery chemistry

Details of setting can be found as Chapter 4.6

BAT5 Temp
V-Sen

Connects to BTS' black cable Connects to BTS' white cable Connects to BTS' red cable

For battery temperature sensing
For voltage sensing

RED Ring Terminal connect to Battery +ve

Fuse specification

No. Print 6 Alternator
7 AUX BAT

Specification 30A/32VDC for PMDCS30
20A/32VDC

Colour Amber
Yellow

Quantity 2
2

Protection for Input from alternator Output to charge auxiliary battery

11

STATUS INDICATORS LED codes

No. Print 4-2 Alternator Present

4-3 Charger faulty

4-5 Alternator over voltage

4-6

Fridge/Load Short Circuit*

4-7

Fridge/Load Output Overload*

4-9 Bulk Time out

4-12 Output Overvoltage

4-13 Fridge/Load output

4-14 Softstart Charging

4-15 Bulk charging

4-16 Absorption charging

4-17

Float charging (charged)

4-18 Recycle Mode

* (PMDCS30-20 Only)

Power
Green Light On
Green Light On
Green Light On
Green Light On
Green Light On
Green Light On
Green Light On
Green Light On
Green Light On
Green Light On
Green Light On
Green Light On
Green Light On

Fridge/Load
Green Light Off
Green Light Off
Green Light Off
Green Light Flash
Green Light Flash
Green Light Off
Green Light Off
Green Light On
Green Light On
Green Light Off
Green Light Off
Green Light Off
Green Light Off

Alternator
Green Light Off
Green Light Off
Green Light Flash
Green Light On
Green Light On
Green Light On
Green Light Off
Green Light On
Green Light Flash
Green Light On
Green Light Flash
Green Light On
Green Light Flash

Charge
Green Light Off
Green Light Off
Green Light Off
Green Light Off
Green Light Off
Green Light Flash
Green Light Flash
Green Light On
Green Light Flash
Green Light Flash
Green Light On
Green Light On
Green Light Flash

Fault
Red Light On
Red Light Flash
Red Light On
Red Light On
Red Light Flash
Red Light Flash
Red Light Off
Red Light Off
Red Light Off
Red Light Off
Red Light Off
Red Light Off

DIP SWITCH SETTING Dip switch setting for output current

Output Current settings

Pin 1

Pin 2

Charge current (Max Amps)

Not used

OFF

15

Not used

ON

30 (Default)

Dip switch setting for battery type

Dip Switches Set output current and battery type
UP = OFF DOWN = ON

Dip switch for battery type setting

Pin 3

Pin 4

OFF

OFF

OFF

ON

ON

OFF

ON

ON

Battery type
AGM (Default setting)
GEL LFP WET

Absorption charging voltage
14.4V
14.1V 14.2V 14.7V

Float charging voltage
13.5V
13.5V 13.5V 13.5V

12

Do not connect PMDCS30 to AC Mains

Please ensure the connections are tight and are of the correct polarity. Damaged caused by improper installation may void warranty.

SPECIFICATIONS
Model Number Electrical Alternator input voltage range (Intelligent type) Automatic activation D+ Absorption charge voltage Float charge voltage Charge current Total current of load and charging Maximum charging efficiency Temperature compensation Voltage compensation Charge algorithm Protection
Communication Storage temperature Operating temperature Enclosure Battery Connection Protection category Weight Dimensions (h*w*d) Standards Emission

PMDCS30
12~16VDC Yes
Default Setting: 14.4VDC Default Setting: 13.5VDC <30A <30A 96% Default Setting: -3mV/°C/cell Yes Premium II multi stage · Battery charger over temperature · Over load · Short circuit RS485, RJ45 connector -40°C ~70°C -40°C ~70°C
Cable with connector IP20 1.0kg 181*148*52mm
ECE 10R-06, EN61000-6-1, EN61000-6-3

13

INVCHRD-BT INVERTER / CHARGER AND BATTERY MONITOR.
Monitors the batteries State of Charge, current and voltage via phone using Bluetooth. Monitoring communication directly with the Inverter Charger and the battery so no additional shunts are required making it easy for installation and use. With a remote battery switch integrated in the monitor, turning the Inverter Charger on and off remotely allowing for the inverter / charger or battery to be stored elsewhere.

SPECIFICATIONS PART NO WORKING VOLTAGE WORING CURRENT
COMMUNICATION WORKING TEMPERATURE WEIGHT IP RATING

INVCHRD-BT 12V Screen ON 50Ma Screen OFF 20mA RS485, Bluetooth -20°C ~ 65°C 50g IP 20

14

ACCESS THE APP VIA GOOGLE PLAY AND THE APP STORE To connect your phone or smart device with the remote monitor, you will first need to download the app from the Google Play or Apple store. Scan the QR codes below to download directly or search your relevant app store for "APPNAMEHERE".
15

BATTERY LB200-HD 12V HIGH DISCHARGE 200AH LITHIUM BATTERY
LB200-HD boast impressive capabilities and are ideal for 4WDs and caravans with high power demands.

SPECIFICATIONS PART NO NOMINAL VOLTAGE NOMINAL CAPACITY NOMINAL ENERGY CHARGE VOLTAGE DISCHARGE CUT-OFF VOLTAGE STANDARD CHARGE CURRENT MAXIMUM CHARGER CURRENT MAXIMUM DISCHARGE CURRENT PEAK DISCHARGE CURRENT OPERATING TEMPERATURE MAXIMUM NUMBER OF BATTERIES IN PARALLEL NUMBER OF DISCHARGE CYCLES WEIGHT IP RATING
16

LB200-HD 12.8V 200Ah 2560Wh 14.2V 11.2V 100 Amps 200 Amps 200 Amps 300 Amps (10Mins) -20°C ~ 60°C
4
3000 22KG IP20

STRUCTURE AND INSTALLATION

MONITOR

103

60

110

31

83.5 70

93

8

INTELLI-GRID IG2-BM
SC540 PMDCS30

INVCHR2

17

WARRANTY STATEMENT
Applicable only to product sold in Australia Brown & Watson International Pty Ltd of 1500 Ferntree Gully Road, Knoxfield, Vic., telephone (03) 9730 6000, fax (03) 9730 6050, warrants that all products described in its current catalogue (save and except for all bulbs and lenses whether made of glass or some other substance) will under normal use and service be free of failures in material and workmanship for a period of two (2) year (unless this period has been extended as indicated elsewhere) from the date of the original purchase by the consumer as marked on the invoice. This warranty does not cover ordinary wear and tear, abuse, alteration of products or damage caused by the consumer. Projecta solar panels are covered by a 1 year warranty for materials and workmanship and a 20 year warranty for at least 80% power output.
To make a warranty claim the consumer must deliver the product at their cost to the original place of purchase or to any other place which may be nominated by either BWI or the retailer from where the product was bought in order that a warranty assessment may be performed. The consumer must also deliver the original invoice evidencing the date and place of purchase together with an explanation in writing as to the nature of the claim.
In the event that the claim is determined to be for a minor failure of the product then BWI reserves the right to repair or replace it at its discretion. In the event that a major failure is determined the consumer will be entitled to a replacement or a refund as well as compensation for any other reasonably foreseeable loss or damage.
This warranty is in addition to any other rights or remedies that the consumer may have under State or Federal legislation.
IMPORTANT NOTE Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.

Distributed by
AUSTRALIA Brown & Watson International Pty. Ltd. Knoxfield Victoria 3180 Phone: (03) 9730 6000 Fax: (03) 9730 6050 National Toll Free: 1800 113 443
NEW ZEALAND OFFICE Griffiths Equipment Ltd. 19 Bell Avenue, Mount Wellington, Auckland 1060, New Zealand Phone: (09) 525 4575 Fax: (09) 579 1192

ISXXX Issue 1: XX/10/2022



References

Adobe PDF Library 16.0 Adobe InDesign 16.4 (Macintosh)