69-1371
This is a legacy product document supported by Resideo. It is no longer manufactured

4074FAB Resistor

APPLICATION
The 1000-ohm, three-watt 4074FAB Resistor is used in certain applications to assure compatibility with powerstealing thermostats.
Use this Resistor When Installing...
· Forced air systems using ST9120 or ST9141 Electronic Fan Timer.
· Taco zone valve applications. · Trane electric heat air handlers. · Oil systems using Honeywell R8184 Oil Primaries. · Cool only applications.
INSTALLATION
When Installing this Product...
1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition.
2. Check the ratings on the resistor to make sure the resistor is suitable for your application.
3. Installer must be a trained, experienced service technician.
4. After installation is complete, check out product operation as provided in these instructions.
CAUTION
Electrical Hazard. Can Cause Electrical Shock or Equipment Damage. Disconnect power supply before installing resistor.
To Install The Resistor
1. Loosen terminal screws as shown in the application drawing.
2. Slide the resistor leads under the terminal screws and tighten the screws.
3. Turn on the system power.

INSTALLATION INSTRUCTIONS

ST9120A-G
C GYWR 1
1 DISCONNECT POWER SUPPLY BEFORE INSTALLATION. M16650
Fig. 1. Connect resistor to ST9141 Fan Timer terminals C and W.
THERMOSTAT

1 L1 (HOT)
L2

R

W

TACO ZONE VALVE
RESISTOR 2
1 2 3

1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.

2 BEND RESISTOR AWAY FROM ZONE VALVE CASE TO PREVENT SHORTING.

M15401A

Fig. 2. Connect resistor to Taco zone valve terminals 1 and 2.

® U.S. Registered Trademark Copyright © 2003 Honeywell International Inc. ·

· All Rights Reserved

69-1371-1

4074FAB

TERMINAL BOARD CONNECTION
TO THERMOSTAT

W TERMINAL

1 B TERMINAL
(OPTIONAL)

1 DISCONNECT POWER SUPPLY BEFORE INSTALLATION. M16653

Fig. 3. Connect resistor across terminals W and B on Trane electric heat air handlers.

R8184G T

T

RESET

F 2
F
1

1 DISCONNECT POWER SUPPLY BEFORE INSTALLATION.

2 BE SURE RESISTOR IS MOUNTED ON LOWER

T AND F TERMINALS.

M16651

Fig. 4. Connect resistor to R8184 Oil Primary terminals T and F.

R

Y

W

4074FAB

1 L1 (HOT)
L2

COMPRESSOR CONTACTOR

1 POWER SUPPLY. PROVIDE DISCONNECT MEANS

AND OVERLOAD PROTECTION AS REQUIRED.

M16652

Fig. 5. Connect resistor for cool only application.

CHECKOUT
1. Set the thermostat heating setpoint to 10°F (6°C) above the room temperature.
2. Watch the thermostat display for approximately five minutes to be sure the display does not go blank during the call for heat.
3. Reset the thermostat to a comfortable setpoint.

Automation and Control Solutions Honeywell International, Inc. 1985 Douglas Drive North Golden Valley, MN 55422

Honeywell Limited-Honeywell Limitée 35 Dynamic Drive Scarborough, Ontario M1V 4Z0

69-1371-1 G.H. 9-03

www.honeywell.com/yourhome

