Solaira SMaRT Timer On/Off Control

SMRTTIM60 and SMRTTIM40

Installation & User Manual

KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE

SAFETY WARNING

⚠️ ALL INSTALLATIONS/SERVICE MUST ONLY BE PERFORMED BY A LICENSED/CERTIFIED ELECTRICIAN TO LOCAL AND NATIONAL ELECTRICAL CODE (NEC).

⚠️ WARNING: SHOCK AND FIRE HAZARD:

ELECTRICAL RATING

⚠️ WARNING SERIOUS INJURY OR DEATH COULD OCCUR, DISCONNECT ALL POWER PRIOR TO SERVICE

Certified: SPE-1000 CANADA INSPECTED

Introduction

The SMRTTIM60 and SMRTTIM40 are part of a family of standalone controllers designed to provide energy saving when used with quartz infrared halogen lamps or other heating and lighting products. These TIMER models switch the lamps on for a predetermined time period of between 1 and 60 minutes. The microcontroller-based unit incorporates zero-voltage switching and a soft-start function to eliminate the lamps' initial high inrush current – potentially increasing lamp life by as much as 30%. Installation of the unit is simple and once installed is relatively maintenance-free.

Product Features

Applications

Bus stops, patio areas, smoking shelters, restaurants, warehouses, workshops.

Installation

Important: Read carefully the following information before installing the unit.

The SMRTTIM60 and SMRTTIM40 should be fixed securely using the four mounting holes accessible from the front of the unit. Remove the lid to access the mounting holes. To ease installation, a mounting template is provided to locate the 4 mounting hole centres.

IMPORTANT! The unit must be orientated with the cable glands facing down.

Wiring

SAFETY FIRST

The Solaira SMaRT Timer is a high-power electrical device and MUST ONLY BE INSTALLED BY A CERTIFIED ELECTRICIAN WITH REFERENCE TO LOCAL, STATE/PROVINCIAL AND FEDERAL NEX XODES AND ELECTRICAL REQUIREMENTS.

⚠️ Warning! Isolate the mains supply before commencing any work on this unit. Ensure all earth wires are connected to maintain earth continuity to the lamp fittings.

⚠️ Warning! Disconnect the power supply before commencing any work on the unit. Failure to do so could result in serious injury or fatality.

Wiring SMRTTIM60

The unit is fitted with three cable glands. Only one cable should be fitted per strain relief to prevent degrading the unit's water resistant IP rating. To connect 4 lamps, refer to the Wiring Diagram for an alternative configuration using two junction boxes.

The power supply connects to the terminal block marked ‘LINE'. Connect the supply LIVE to the ‘L' terminal, NEUTRAL or LINE 2 to the 'N' terminal and GROUND to the 'E' terminal.

The heaters connect to the terminal block marked ‘LOAD'. Connect the load LIVE to the 'L' terminal, NEUTRAL or LINE 2 to the 'N' terminal and Ground to the 'E' terminal.

Important! Ensure all ground wires are connected to maintain ground continuity to the heater fittings. Check all wiring and make sure the cable glands are tightened.

Illustrative Wiring Diagram SMRTTIM60

Connection diagram is for illustrative purpose only. Installation must be carried out by certified electrician to local, state/provincial and National Electric Code (NEC) requirements. Inforesight Consumer Products Inc. assumes no responsibility for the heaters or controller electrical plan or installation.

⚠️ WARNING: SERIOUS INJURY OR DEATH COULD OCCUR, DISCONNECT ALL POWER PRIOR TO SERVICE

Diagram Description: Illustrates the connection of a 230VAC power supply (LIVE, NEUTRAL, EARTH) to the 'LINE' terminal block and four 1500W Infra-red Heater Lamps to the 'LOAD' terminal block. IP65 junction boxes are used for lamp connections. The diagram details the internal terminal layout (L, N, E for LINE and LOAD) and includes CE marking.

Commissioning SMRTTIM60

Set the on-time pre-set (VR2) to a time period of between 1 and 60 minutes. Replace the lid and switch on the mains supply to the unit. Press the push-button on the front of the unit to switch the lamps on.

IMPORTANT! When wall mounting, the unit must be orientated with the cable glands facing down.

SMRTTIM60 Mounting Template

Diagram Description: A template showing dimensions of 115mm x 115mm with four mounting holes for installation. It warns that drilling through the enclosure will invalidate the warranty.

Wiring SMRTTIM40

The unit is fitted with two cable glands. Only one cable should be fitted per gland to prevent degrading the unit's IP rating. When fitting two lamps, refer to 'Wiring Diagram' for an alternative wiring configuration using a junction box.

The power supply connects to the terminal block marked ‘LINE'. Connect the supply LIVE to the 'L' terminal, NEUTRAL to the 'N' terminal and EARTH to the 'E' terminal.

The heaters connect to the terminal block marked 'LOAD'. Connect the load LIVE to the 'L' terminal, NEUTRAL to the 'N' terminal and EARTH to the 'E' terminal. If two lamps are to be fitted they must be wired in parallel.

Check all wiring and make sure the cable glands are tightened.

Illustrative Wiring Diagram SMRTTIM40

Connection diagram is for illustrative purpose only. Installation must be carried out by certified electrician to local, state/provincial and National Electric Code (NEC) requirements. Inforesight Consumer Products Inc. assumes no responsibility for the heaters or controller electrical plan or installation.

⚠️ WARNING: SERIOUS INJURY OR DEATH COULD OCCUR, DISCONNECT ALL POWER PRIOR TO SERVICE

Diagram Description: Shows the connection of a 230VAC power supply (LIVE, NEUTRAL, EARTH) to the 'LINE' terminal block and two 1500W Infra-red Heater Lamps to the 'LOAD' terminal block. An IP65 junction box is used for lamp connections, and lamps must be wired in parallel. The diagram details the internal terminal layout (L, N, E for LINE and LOAD).

Commissioning SMRTTIM40

Set the on-time pre-set (VR1) to a time period of between 1 and 60 minutes. Replace the lid and switch on the main power supply to the unit. Press the push-button on the front of the unit to switch the lamps on.

SMRTTIM40 Mounting Plate

Diagram Description: A template showing dimensions of 83.5mm x 83.5mm with four mounting holes for installation. It warns that drilling through the enclosure will invalidate the warranty.

Technical Specification

SMRTTIM60

Parameter Specification
Supply Voltage 230VAC +/- 10% 50/60 Hz
Switching Capacity 6000W Max.
Lamp On-Time 1 to 60 minutes
Current Consumption (control circuit) 20mA
Terminals 6.0mm² Rising Clamp
Operating Temperature -20 to 40°C
Protection Rating IP65
Gland Diameter Max Cable Entry 2.5mm²
Enclosure Dimensions (WxLxH) 130x130x75 (mm)

SMRTTIM40

Parameter Specification
Supply Voltage 230VAC +/- 10% 50/60 Hz
Switching Capacity 4000W Max.
Lamp On-Time 1 to 60 minutes
Current Consumption (control circuit) 50mA
Terminals 2.5mm² Rising Clamp
Operating Temperature -20 to 40°C
Protection Rating IP65
Gland Diameter Max Cable Entry 2.5mm²
Enclosure Dimensions (WxLxH) 100x100x60 (mm)

Troubleshooting

⚠️ Warning! Isolate the mains supply before commencing any work on the unit. Failure to do so could result in serious injury or fatality.

Problem: Lamps do not switch on.

Problem: Lamps do not switch off.

LIMITATION OF LIABILITY

It is understood and agreed that seller's liability whether in contract, in tort, under any warranty, in negligence or otherwise shall not exceed the return of the amount of the purchase price paid by purchaser and under no circumstances shall seller be liable for special, indirect, or consequential damages. The price stated for the equipment is a consideration in limiting seller's liability. No action, regardless of form, arising out of the transactions may be brought by purchaser more than one year after the cause of action has accrued.

WARRANTY

  1. SOLAIRA CONTROL products are guaranteed to be free from mechanical and electrical defects for a period of one year from date of shipment under normal use and service provided installation is made in accordance with manufacturers' recommendations.
  2. Parts deemed defective shall be repaired or replaced at manufacturer's option and at manufacturer's expense but shall not include foreign or federal excise taxes, state or municipal sale or use taxes, all such taxes not limited to the foregoing being responsibility of the purchaser.
  3. No charge for travel and/or mileage will be allowed to purchaser.
  4. SOLAIRA reserves the right to make changes in design or make any improvements on any products. The right is always reserved to modify equipment because of new technology, underwriter's requirements and/or government regulations.
  5. The following are not covered under warranty:
    • INSTALLATION OF CONTROL BY NON-CERTIFIED ELECTRICIAN.
    • Failure from neglect, abuse, careless handling and mis-application of unit.
    • Failure to observe guidelines for installation or improper voltage hook-up.
    • Failure caused by improper installation and not following local, state/provincial and federal electrical guidelines.
    • Unless specifically allowed by SOLAIRA CONTROLS, no other charges may be included under warranty.

Notice

Inforesight Consumer Products Inc. website, product information and products can be accessed from Canada and other countries around the world. Customer understands that some or all products provided by Inforesight Consumer Products Inc. may not be available for purchase or installation in certain jurisdictions or geographical areas. Inforesight Consumer Products Inc. reserves the right, in its sole discretion, to exclude or otherwise limit the provision of any product to a person or entity residing in any jurisdiction or geographical area outside of Canada.

Inforesight Consumer Products Inc. provides general product information, installation guidelines and procedures and Customer understands that Customer is solely and exclusively responsible for installation of the product and ascertaining all applicable local municipal, provincial, state, and federal NEC (National Electrical Code) rules, by-law, ordinances and guidelines applicable to the installation of any Inforesight Consumer Products Inc. products. Customer must strictly adhere to and be compliant with the local rules, laws, ordinances and legal requirements for the safe installation and use of any Inforesight Consumer Products Inc. products. Instruction manuals are included with the product packaging and copies of our instruction manuals are available upon request. Under no circumstances shall Inforesight Consumer Products Inc. or its affiliated entities, employees, agents, shareholders, officers or directors be liable to Customer or any third party for any product installations and Customer releases Inforesight Consumer Products Inc. from any and all losses, death, personal injury, property damage, other damages, rights, claims, demands and actions of any kind arising from the Customer's installation and use of the product, whether the installation was or was not in accord with the provided instruction manual and/or in compliance with applicable local laws.

Solaira™ is a registered trademark of Inforesight Consumer Products Inc.

Contact Information:
Inforesight Consumer Products Inc.
125 Traders Blvd. # 4, Mississauga, Ontario, Canada, M4Z 2H3
Tel: 905-568-7655, EXT 23 SERVICE, Fax: 905-568-7521
Email: info@solairaheaters.com

Models: SMRTTIM60 SMaRT Timer On Off Control, SMRTTIM60, SMaRT Timer On Off Control, On Off Control, Off Control, Control