Features & Specifications
Intended Use
Designed for high mounting heights requiring high efficiencies, horizontal illumination, premium glare control, and total enclosure. Ideal for heavy manufacturing areas, gymnasiums, and wet location applications.
Construction
Housing: Vertically seamed, heavy-duty, die-cast aluminum halves. Ballast and electrical components are heat-sinked and horizontally opposed. Integral splice box mounting flange ensures structural integrity.
Finish: Electrostatically applied white polyester powder paint.
Optics
One-piece totally enclosed and gasketing Arc Tek II™ spun aluminum, anodized reflector combines high efficiency with an extended shielding angle for high performance optical control. Lens assembly is hinged and latched for easy maintenance.
Electrical
Ballast: All ballasts are 100% factory tested. High Pressure Sodium: Constant wattage autotransformer; Metal Halide: D.O.E 2017 and EISA 2017 compliant Pulse Start, Super Constant Wattage Autotransformer. All US shipments must order SCWA option. CSA, NOM or INTL required for probe start shipments outside the US.
Socket: Vertically oriented mogul base PROTECTED EXCLUSIONARY base "PINK" socket with copper alloy nickel plated screw shell and center contact. For use with “O” rated protected metal halide lamps only.
Installation
Ballast housing: 16-gauge galvanized steel pendant splice box with white polyester powder finish. Removable box slides on integral die-cast aluminum housing mounting flange and mounts to 3/4" pendant conduit prior to ballast housing installation. Matching wire access cover accepts RELOC® modular wiring. Complete assembly meets or exceeds UL 50-pound pull test.
Optic mounting: Four 8-32 zinc plated, tri-lobular, thread-rolling screws arranged concentrically around the lamp socket. 16-gauge galvanized steel support ring with matching keyhole slot pattern for vibration resistant mounting.
Listings
UL listed -30°C to 55°C ambient operations and damp locations, 65°C available. UL Listed to U.S. and Canadian safety standards (see Options). NOM Certified (see Options). 1000M pulse start -30°C to 40°C.
Warranty
1-year limited warranty. Complete warranty terms located at: www.acuitybrands.com/support/warranty/terms-and-conditions
Specifications
Product Image Description: The fixture is a high bay industrial light with a robust die-cast aluminum housing, a large, reflective optical assembly, and a protective lens. It is designed for ceiling mounting via a pendant or hook system.
- Height: 24-3/8 inches (61.9 cm)
- Reflector height: 17-3/8 inches (44.2 cm)
- Width: 23 inches (58.4 cm)
- Weight: 50 lbs (22.7 kg)
All dimensions are inches (centimeters) unless otherwise indicated.
Lamp Types:
- Metal Halide: 350W - 1000W
- High Pressure Sodium: 400W - 1000W
Recommended Mounting Height: 25' to 45'
Note: Actual performance may differ as a result of end-user environment and application. Specifications subject to change without notice.
Ordering Information
Lead times will vary depending on options selected. Consult with your sales representative.
Example: TE 1000M E22 M 120
Series, Wattage, Reflector, Distribution, Voltage, Ballast Combinations
Series | Wattage | Reflector | Distribution | Voltage | Ballast |
---|---|---|---|---|---|
TE | Metal halide (350M, 400M¹) | N (Narrow, 350M, 400S-1000S only) | C (Concentrating) | 120 | (blank) Standard magnetic ballast⁶ |
High pressure sodium (400S, 1000S) | 208³ | CWI Constant wattage isolated⁶ | |||
Metal halide (1000M) | M (Medium, 1000M only) | S (Spread, 1000M only) | 240³,⁴ | Pulse Start | |
277 | SCWA Super constant wattage autotransformer | ||||
347 | RLB Regulated lag ballast | ||||
480³,⁴ | SCWI Isolated SCWA⁶ |
Note: For shipments to U.S. Territories, SCWA must be specified to comply with EISA. Excludes 1000W.
Options (Shipped installed in fixture)
Code | Description |
---|---|
SF | Single fuse (120, 277, 347V)⁷ |
DF | Double fuse (208, 240, 480V)⁷ |
EC | Emergency circuit⁸,⁹ |
QRS | Quartz restrike system⁸,⁹ |
QRSTD | QRS time delay⁸,⁹ |
HA | 65°C ambient operation¹⁰ |
TOB | Through-wire outlet box |
LCPP | Loop, cord, plug requires TPH, PPH⁷,¹¹,¹² |
LC3P | Loop, 3' cord, 15A NEMA twist-lock plug⁷,¹¹,¹² |
HC3P | Hook, 3' cord, 15A NEMA twist-lock plug⁷,¹¹,¹² |
LOCS | Loop, 5' white cord, RELOC OCS⁷,¹²,¹³ |
HOCS | Hook, 5' white cord, RELOC OCS⁷,¹²,¹³ |
LOCU | Loop, 5' white cord, RELOC OCU⁷,¹¹,¹²,¹³,¹⁴,¹⁵ |
HOCU | Hook, 5' white cord, RELOC OCU⁷,¹¹,¹²,¹³,¹⁴,¹⁵ |
TR | Remote ballast |
RC3NP | TR with prewired 3' cord⁷,¹² |
WL | Wet location UL label |
STSS | Stainless steel screws |
WG | Wireguard |
CSA | Listed and labeled to comply with Canadian Standards |
NOM | NOM Certified (Consult factory)¹⁵ |
Accessories (Order as separate catalog number)
Code | Description |
---|---|
HKF | Fixture hook female¹² |
LPF | Fixture loop female¹² |
SCK | 60" safety chain kit¹² |
TMB | Twin-mounting bar (consult factory)¹² |
HKM | Fixture hook male¹² |
HKMG | Grommeted fixture hook male¹² |
LPM | Fixture loop male¹² |
LPMG | Grommeted fixture loop male¹² |
TPH | Throughwire power hook¹² |
PPH | Pendant power hook¹² |
Notes
- ¹ Metal halide wattage will not comply with California Title 20 regulations.
- ² Not available with 480V.
- ³ Requires CWI or RLB option in Canada for MH. Available in 175-400W.
- ⁴ Requires CWI or MRB option in Canada for HPS. Available in 70-400W.
- ⁵ Optional multi-tap ballast (120, 208, 240, 277V or 120,277,347 in Canada). For voltage specific options specify tap position (TB1=120V, TB2=208V, TB3=240V, TB4=277V).
- ⁶ Available for shipments outside of U.S. only.
- ⁷ Must specify voltage or tap position.
- ⁸ Lamp not included.
- ⁹ See Product Selection Guide (QRS Lamp Wattage Table) for maximum lamp wattage.
- ¹⁰ Not available on 1000M pulse start.
- ¹¹ 20A standard 480V.
- ¹² Not available with wet location (WL) option.
- ¹³ May be ordered with 10', 15' and 20' cords. For black cord, specify BK (i.e. HOCSBK).
- ¹⁴ For specific ordering information, see Product Selection Guide.
- ¹⁵ Not available with 350M.
Photometrics
See www.lithonia.com.