Installation Guide for LUTRON models including: CNT10176, CNT10176 Push Button Boost Timer, Push Button Boost Timer, Button Boost Timer, Boost Timer, Timer

Search Results: PROD-SLB060-EN - Public


File Info : application/pdf, 4 Pages, 727.86KB

PDF preview unavailable. Download the PDF instead.

18-HE143D1-1A-EN 11192024
Installer's Guide

18-HE143D1-1A-EN

Push Button Boost Timer Point-of-Use (PBT) - CNT10176 Push Button Point-of-Use Control (PBL) - CNT10175 Percent Timer Control (PTL) - CNT10174

WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING
ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES IMPORTANT -- This Document is customer property and is to remain with this unit. Please return to service information pack upon completion of work.

REPLACEMENT INSTALLER'S GUIDE
ELECTRICAL CONTROLS
! WARNING
HAZARDOUS VOLTAGE ­ DISCONNECT POWER BEFORE SERVICING
Note: Proper Wiring Size Selection and Wiring Installation Is The Responsibility of the Electrical Contractor.
Push Button Boost Timer Point-of-Use Control (PBT) OPERATION: The Push Button Boost Timer (PBT) point-ofuse control with indicator light is compatible with the ERV unit. The PBT will operate your ERV for either 20, 40, or 60 minutes based upon how many times the logo button has been pushed. The indicator light on the front of the PBT control is on whenever the ERV is operating, unless operating due to an additional control wired directly to your ERV. 20-40-60 Minute Ventilation Control: · Press the logo and your ventilator will run
for 20 minutes. Press again and the unit will run 40 minutes. A third press provides for 60 minutes of operation. · You can cancel a cycle at anytime. Just press the logo for a fourth time. · You can start another cycle by pressing the logo.

NOTE: For ERV systems with more than one control: Another control other than the push button may be causing your ventilator to run. If you wish to keep your ventilator from running, check that none of your controls are calling for unit operation.
INSTALLATION: 1. To hook the PBT up to the unit, expose the
ends of two wires, and push one into the `R' terminal and one into the `C' terminal. Wire Size: 18­22 gauge, no more than 500 feet. Wiring is non-polar. 2. Install control in a standard 2" x 4" electrical box, with a minimum depth of 1.5", with the two screws provided. 3. To add a PBL Control, two wires should be attached to the `PB' positions on the terminal block on the back of the PBT. Connect `PB' wires in a similar fashion as `R' and `C' terminal wires.

FRONT

BACK

Installer's Guide

4. For two PBL controls, one wire from each can be twisted together and inserted into a single position on the terminal block on the PBT. The wires must be a maximum 18 gauge solid wire. If more than two PBL controls are attached or 18 gauge stranded

wire is used, then pigtails must be inserted into the `PB' positions on the PBT and the leads attached to the pigtails with wire nuts. 5. Use Lutron DecoraTM cover plate to complete installation (single cover plate included).

WIRING DIAGRAM:

* EXCEPT WHEN ERV IS OPERATING DUE TO AN ADDITIONAL CONTROL WIRED DIRECTLY TO THE UNIT.

Push Button Point-of-Use Control (PBL) OPERATION:

The Push Button point-of-use control with

indicator Light (PBL) works in conjunction

with one Percentage Timer Control (PTL)

or with one Push Button Timer (PBT) and is

compatible with the ERV unit. The PBL will

operate your ERV for either 20, 40, or 60

minutes based upon how many times the logo

button has been pushed. The indicator light on

the front of the PBL control is on whenever the

ERV is operating, unless operating due to an

FRONT

BACK

additional control wired directly to your ERV.

The PBL control must be properly wired to a · You can cancel a cycle at anytime. Just

PTL or PBT control to operate the ERV.

press the logo and hold for about five

20-40-60 Minute Ventilation Control:

seconds.

· Press the logo and your ventilator will run · You can start another cycle by pressing the

for 20 minutes. Press again and the unit will

logo.

run 40 minutes. A third press provides for

60 minutes of operation. The PTL or PBT

NOTE: For ERV systems with more than

control does not need to be on for the PBL

one control: Another control other than the

Control to operate the ERV unit.

push button may be causing your ventilator

2

18-HE143D1-1A-EN

Installer's Guide

to run. If you wish to keep your ventilator from running, check that none of your controls are calling for unit operation.
INSTALLATION: 1. Attach two wires to the back of the PBL
Control under the screws at the bottom. Tighten down the screws being careful not to over-tighten. Wire Size: 18­22 gauge, no more than 500 feet. Wiring is non-polar. 2. Install control in a standard 2" x 4" electrical box, with a minimum depth of 1.5", with the two screws provided. 3. Two wires from the PBL Control should be attached to the `PB' positions on the

terminal block on the back of the Percent Timer Control (PTL ) or Push Button Timer (PBT). 4. For two PBL controls, one wire from each can be twisted together and inserted into a single position on the terminal block on the PTL or PBT. The wires must be a maximum 18 gauge solid wire. If more than two PBL controls are attached or 18 gauge stranded wire is used then pigtails must be inserted into the `PB' positions on the Percent Timer Control and the leads attached to the pigtails with wire nuts. 5. Use Lutron DecoraTM cover plate to complete installation (single cover plate included).

WIRING DIAGRAM:

* EXCEPT WHEN ERV IS OPERATING DUE TO AN ADDITIONAL CONTROL WIRED DIRECTLY TO THE UNIT.

Percentage Timer Control (PTL) OPERATION:
The Percentage Timer Control with indicator lights (PTL) is the primary control for ERV unit. This proportional runtime control will operate your ERV an adjustable amount of time each hour. When the "Runtime %" light is on, the PTL control is telling your ERV to operate. Additionally, the PTL can be set to turn your ERV off or to operate constantly. ERV operation time will vary from application to application as well as time of year, lifestyle, indoor air

quality concerns and other factors. Discuss any questions with your HVAC professional or contact supplier directly. Constant Operation: Press the button until the light next to "100" is lit. Operation Each Hour: Run time of your ERV can be adjusted from 10%, or 6 minutes each hour, up to 100% operation in 10% increments. Simply press the button until the light next to the desired percentage amount is lit. You can increase or decrease the run time based upon daily, weekly or monthly variations in

18-HE143D1-1A-EN

3

occupancy levels, indoor odors, cold weather winter humidity, or other indoor air quality concerns as needed. FOR NO REGULAR OPERATION: Press the logo until all lights are off. The control is off.

4. Use Lutron DecoraTM cover plate to complete installation (single cover plate included).

INSTALLATION: 1. Install control in a standard 2" x 4" electrical
box, with a minimum depth of 1.5", with the two screws provided. 2. Wire Size: 18­22 gauge, no more than 500 feet. Wiring is non-polar. 3. The two wires from the ERV should be attached to the `C' and `R' positions on the terminal block on the back of the PTL Control.

PERCENTAGE RUN TIME TABLES

RUNTIME % SETTING
10 20 30 40 50 60 70 80 90 100

MINUTES OF OPERATION (PER HOUR)
6 12 18 24 30 36 42 48 54 60

EQUIVALENT CONTINUOUS OPERATION CFM

EV90/P
9 18 27 36 45 54 63 72 81 90

EV130
13 26 39 52 65 78 91 104 117 130

EV200
18 36 54 72 91 109 127 145 163 181

EV240
24 48 72 96 120 144 168 192 216 240

EV300
30 59 89 119 149 178 208 238 267 297

FRONT

BACK

ASHRAE 62.2 2013/16 RESIDENTIAL VENTILATION AIR REQUIREMENTS
CONTINUOUS CFM
BEDROOMS

FLOOR AREA (FT2) 1

2

3

4

5

<500

30

38

45

53

60

501 - 1000

45

53

60

68

75

1001 - 1500 1501 - 2000 2001 - 2500

60

68

75

83

90

75

83

90

98

105

90

98

105

113

120

2501 - 3000

105

113

120

128

135

3001 - 3500

120

128

135

143

150

3501 - 4000

135 143 150 158 165

4001 - 4500

150 158 165 173 180

4501 - 5000

165 173 180 188 195

WIRING DIAGRAM:

PTL Percent Timer R C PB PB

Use one (1) PTL and up to six (6) PBL controls, wired in parallel.

PBL

PBL

Unit Internal Wiring

Remove Jumper across Low-voltage terminal if present.
To install one or more additional low-voltage controls other than PTL or PBL, install a 150 ohm resistor (rated at 1/8 watt or more) between one terminal on the ventilator and one of the wires to the other controls as shown. (A 150 ohm 1/8 watt resistor is provided with a PTL) Wire the other controls in parallel with each other.

About Trane and American Standard Heating and Air Conditioning Trane and American Standard create comfortable, energy efficient indoor environments for residential applications. For more information, please visit www.trane.com or www.americanstandardair.com

The manufacturer has a policy of continuous data improvement and it reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices.

18-HE143D1-1A-EN 19 Oct 2024 Supersedes (New)

© 2024

