Installation Guide for SIO models including: XEL-BSSRT, XEL-BSSRF, XEL-BSSRH, XEL-BSSRT Ethernet IO Adapter, XEL-BSSRT, Ethernet IO Adapter, IO Adapter, Adapter

윤병찬 (尹炳贊,B.C.Yun)

경고 주의

Nov 17, 2024 — 주의. ① 제품의 정격전압과 단자 배열을 확인한 후 정확하게 배선하여 주십시오. ② 배선 시 단자의 나사를 규정 토크로 단단하게 조여 주십시오.


File Info : application/pdf, 2 Pages, 737.96KB

PDF preview unavailable. Download the PDF instead.

SIO-18 XEL-BSSRT and 2 others Installation Guide V1.4
C/N: 10310001663

Programmable Logic Controller  

Smart I/O

XEL-BSSRT/F/H

   PLC     .             .

1   

 /  



          



            


      .         .   , , , ,    .

         .          .       .       .      ,    .         .         .         .         100mm  
 .

2   

        .

No





1 

055

2 

-2570

3 

595%RH,    

4 

595%RH,    

   

-









5f<8.4

-

3.5mm

5



8.4f150

9.8(1g)

-

   







5f<8.4

-

1.75mm

X,Y, Z  
10

8.4f150

4.9(0.5g)

-

 -
IEC 61131-2

3   

         .

1) XG5000 Software

: V4.30 

4  

       .





   

RAPIEnet, EtherNet/IP, Modbus-TCP, BOOTP, DHCP 100/1000Mbps

 
     

: Category 5e  STP(Shielded Twisted-pair)  : (MMF)/ (SMF)  8 3.0A1)

  

BSSRT: 710, BSSRF: 750, BSSRH: 730

1)           

 .

5       (mm)
    .         .    .

     

No.



   LED

          PADT  USB


RAPIEnet/IP   ,    LED     DC24V       ,   XG5000   USB 

 USB    USB    

  

    

 LED   

LED



RUN

    

 

RMS

     

 

RNS
RELAY
LINK/ACT1 LINK/ACT2

     
 
           


 Off  RUN  STOP                       ,  ,  ,    duplex     1         IP/         ,  , Heartbeat Error     Off   On
Link=No, Activity=NA
1G Link=Yes, Activity=No
1G Link=Yes, Activity=Yes
10/100M Link=Yes, Activity=No
10/100M Link=Yes, Activity=Yes

6    
         . 1)            .         .          .

2)        .     . (    .)

7 

  

1) 10/100/1000BASE-TX  (-) 100m.

2)    (Auto Crossover)    

       .

 



     

1

TD+

1 ----- 1

1 ----- 3

2

TD-

2 ----- 2

2 ----- 6

3

RD+

3 ----- 3

3 ----- 1

4

TRD2+

4 ----- 4

4 ----- 7

5

TRD2-

5 ----- 5

6

RD-

6 ----- 6

5 ----- 8 6 ----- 2

7

TRD3+

7 ----- 7

7 ----- 4

8

TRD3-

8 ----- 8

8 ----- 5

8  
      36.        .       ,        .    
1) ,  (, ,  CAP, , LCD )  2)     ··   3)         4)         5)       6)    ·       7) ,            8)                .             .

LS ELECTRIC Co., Ltd. www.ls-electric.com 10310001663 V1.4 (2024.6)

     !

    ( )

1544-2080

  



TEL:(02)2034-4623~38



TEL:(051)310-6855~60



TEL:(053)603-7741~8

() TEL:(062)510-1891~92

() TEL:(042)820-4240~42

FAX:(02)2034-4057 FAX:(051)310-6851 FAX:(053)603-7788 FAX:(062)526-3262 FAX:(042)820-4298

 ():     4 56 ( 31226).

C/N: 10310001663

Programmable Logic Controller Installation Guide

Smart I/O

XEL-BSSRT/F/H

This installation guide provides simple function information or PLC control. Please read carefully this data sheet and manuals before using products. Especially read precautions then handle the products properly.
1 Safety Precautions
 Meaning of warning and caution label

WARNING CAUTION

WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury
CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices

WARNING
 Do not contact the terminals while the power is applied.  Be sure there are no foreign metallic matters.  Do not manipulate the battery(charge, disassemble, hitting, short, soldering).
CAUTION
 Be sure to check the rated voltage and terminal arrangement before wiring  When wiring, tighten the screw of terminal block with the specified torque range  Do not install the flammable things on surroundings  Do not use the PLC in the environment of direct vibration  Except expert service staff, Do not disassemble or fix or modify the product  Use the PLC in an environment that meets the general specifications contained in
this installation guide.  Be sure that external load does not exceed the rating of output module.  When disposing of PLC and battery, treat it as industrial waste.  I/O signal or communication line shall be wired at least 100mm away from a high-
voltage cable or power line.

2 Operating Environment

 To install, observe the below conditions.

No

Item

Specification

Standard

1 Ambient temp.

0 ~ 55

-

2 Storage temp.

-25 ~ 70

-

3 Ambient humidity

5 ~ 95%RH, non-condensing

-

4 Storage humidity

5 ~ 95%RH, non-condensing

-

Occasional vibration

-

-

Frequency Acceleration Amplitude Number

5f<8.4

-

3.5mm

5

Vibration Resistance

8.4f150 9.8(1g)

-

Continuous vibration

Frequency Acceleration Amplitude

5f<8.4

-

1.75mm

8.4f150 4.9(0.5g)

-

10 times in each
direction for
X, Y, Z

IEC 61131-2

3 Applicable Support Software

 For system configuration, the following version is necessary.

1) XG5000 Software

: V4.30 or above

4 Performance Specifications

 For more information, please refer to user manual.

Item

Specification

Communication protocol

RAPIEnet, EtherNet/IP, Modbus-TCP, BOOTP, DHCP

Transmission speed

100/1000Mbps

Communication cable

Electric: S-FTP over CAT5e Optical: Multi-mode/Single-mode fiber optic cable(MMF/SMF)

Maximum expansion stages Output current
Internal current consumption

8 slot 3.0A*1) BSSRT: 710, BSSRF: 750, BSSRH: 730

*1) Be careful that the sum of the current consumption does not exceed the output current.

5 Parts name and Dimension (mm)
 This is front part of the product. Refer to each name when operating the system. For more information, refer to user's manual.
\

 Parts name and function

No.

Name

 Status LED

 Rotary Switch  Power connector  Media connector  USB connector  USB protection cover  Expansion cover

Description RAPIEnet/IP Adapter operation status LED, Network communication status LED Node Address switch DC24V power input connector Media connector (electric, optical) USB connector to connect with XG5000 Protection cover for USB connector Protection cover for expansion connector

 LED details

LED

Status

Off

RUN

Green On Red On

Green Blink

Green On

Green Blink

RMS

Red On

Red Blink

RNS
RELAY
LINK/ACT1 LINK/ACT2

Green On Green Blink Red On
Red Blink
Off Green On Off Green On Green Blink Yellow On Yellow Blink

Description
Power Off Master module is RUN Master module is STOP Waiting for service Normal Devices setting is not complete Non-restorable error occurs Invalid setting, Restorable error occurs, Parameter errors, Initialization errors, Different speeds or duplexes between ports At least one connection Device is not connected Duplicated IP address/station number is detected Time-out occurs with one or more devices Frame error or heartbeat error occurs Relay Off Relay On Link=No, Activity=NA 1G Link=Yes, Activity=No 1G Link=Yes, Activity=Yes 10/100M Link=Yes, Activity=No 10/100M Link=Yes, Activity=Yes

6 Installing / Removing Modules
 Here describes the method to attach each module to the base or remove it. 1) Installing module  When extension input/output module is installe
of adapter module up.  Push the product and connect it agreement
with hook for fixation of four edges and hook
for connection  After connection, get down the hook for fixation
and fix it completely
2) Removing module

 Push up the hook for disconnection.

 Detach the product with two hands. (Don't force it.)

7 Wiring

 Wiring for Communication 1) 100/10000BASE-TX's max.extended length between nodes is 100m. 2) This module provides Auto Cross Over function so the user can use both cross and

straight cable.

Pin No.

Sign

Cable wiring Straight cable Cross cable

1

TD+

1 ----- 1

1 ----- 3

2

TD-

2 ----- 2

2 ----- 6

3

RD+

3 ----- 3

3 ----- 1

4

TRD2+

4 ----- 4

4 ----- 7

5

TRD2-

5 ----- 5

6

RD-

6 ----- 6

5 ----- 8 6 ----- 2

7

TRD3+

7 ----- 7

7 ----- 4

8

TRD3-

8 ----- 8

8 ----- 5

8 Warranty
 The warranty period is 36 months from the date of manufacture.  The initial diagnosis of faults should be conducted by the user. However, upon request, LS ELECTRIC or its representative(s) can undertake this task for a fee. If the cause of the fault is found to be the responsibility of LS ELECTRIC, this service will be free of charge.  Exclusions from warranty
1) Replacement of consumable and life-limited parts (e.g. relays, fuses, capacitors, batteries, LCDs, etc.)
2) Failures or damages caused by improper conditions or handling outside those specified in the user manual
3) Failures caused by external factors unrelated to the product 4) Failures caused by modifications without LS ELECTRIC's consent 5) Use of the product in unintended ways 6) Failures that cannot be predicted/solved by current scientific technology at the time of manufacture 7) Failures due to external factors such as fire, abnormal voltage, or natural disasters 8) Other cases for which LS ELECTRIC is not responsible  For detailed warranty information, please refer to the user's manual.  The content of the installation guide is subject to change without notice for product performance improvement.

LS ELECTRIC Co., Ltd www.ls-electric.com 10310001663 V1.4 (2024.6)
· E-mail: automation@ls-electric.com

· Headquarter/Seoul Office · LS ELECTRIC Shanghai Office (China) · LS ELECTRIC (Wuxi) Co., Ltd. (Wuxi, China) · LS-ELECTRIC Vietnam Co., Ltd. (Hanoi, Vietnam) · LS ELECTRIC Middle East FZE (Dubai, U.A.E.) · LS ELECTRIC Europe B.V. (Hoofddorf, Netherlands) · LS ELECTRIC Japan Co., Ltd. (Tokyo, Japan) · LS ELECTRIC America Inc. (Chicago, USA)

Tel: 82-2-2034-4033,4888,4703 Tel: 86-21-5237-9977 Tel: 86-510-6851-6666 Tel: 84-93-631-4099 Tel: 971-4-886-5360 Tel: 31-20-654-1424 Tel: 81-3-6268-8241 Tel: 1-800-891-2941

· Factory: 56, Samseong 4-gil, Mokcheon-eup, Dongnam-gu, Cheonan-si, Chungcheongnamdo, 31226, Korea



References

Microsoft Word Microsoft 365용