User Guide for Lumos CONTROLS models including: Cyrus AM, Cyrus AM AC Powered Wireless Microwave Motion and Light Sensor, AC Powered Wireless Microwave Motion and Light Sensor, Wireless Microwave Motion and Light Sensor, Microwave Motion and Light Sensor, Motion and Light Sensor, Light Sensor

Cyrus AM Installation and Quick Start Sheet

Cyrus AM

Cyrus AM - Installation Guide Cyrus AM - Installation Guide The Installation guide of Cyrus AM can be accessed here


File Info : application/pdf, 3 Pages, 2.23MB

PDF preview unavailable. Download the PDF instead.

Cyrus AM Installation and Quick Start Sheet
Cyrus AM
AC Powered Wireless Microwave Motion & Light Sensor

INSTALLATION AND QUICK START SHEET
WARNING AND GUIDELINES!!!
Read and follow all safety instructions!!
DO NOT INSTALL DAMAGED PRODUCT! This product has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
WARNING : TURN THE POWER OFF AT THE CIRCUIT BREAKER BEFORE WIRING
WARNING: Risk of Product Damage Electrostatic Discharge (ESD): ESD can damage product(s). Personal grounding equipment should be worn during all installation or servicing of the unit Do not stretch or use cable sets that are too short or are of insufficient length Do not modify the product Do not mount near gas or electric heater Do not change or alter internal wiring or installation circuitry Do not use product for anything other than its intended use
WARNING - Risk of Electric Shock
Verify that supply voltage is correct by comparing it with the product information Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements All wiring connections should be capped with UL approved recognized wire connectors All unused wiring must be capped
PRODUCT OVERVIEW
Cyrus AM is a BLE5.2 controllable high bay Microwave motion and daylight sensor. This sensor operates on a 90-277VAC input voltage range adopts a 5.8GHz Microwave sensing technology for accurate motion detection. It can be mounted at a maximum height of 12m(39.4ft) and provides a maximum detection range of 17m(55.8ft) diameter. The sensor can be mounted to the ceiling or at the surface using ceiling or surface mount accessories. It can be quickly commissioned, configured, and controlled from any mobile device and can be connected to Lumos Controls cloud for data analytics and configuration management

Do's
Installation should be performed by a qualified electrician
Installation shall be in accordance with all applicable local and NEC codes
Turn the power OFF at circuit breakers before wiring
Observe the correct polarity of output terminal

Dont's Don't use outdoors
Avoid input voltage exceeding maximum rating Don't disassemble the products
-

Specifications Input voltage Input current
Inrush current Surge rating Operating temperature Dimensions (Excludes accessories) Net weight (Excludes accessories) Case temperature Case material Dimensions (Ceiling mount accessories) WMAM-CMK
Dimensions (Surface mount accessories) WMAM-SMK

Value 90­277VAC 9mA@230VAC 15mA@90VAC 4A 4kV 0­80ºC (32 to 176°F) 2.3 X 2.5in (59.8 X 63.1mm) 85g (3.0oz) 70°C (158°F)
ABS Plastic
3.53 x 2.62in (89.7 x 66.8mm)
4.32 x 2.80in (109.8 x 71.2mm)

Remarks Rated input voltage _ _ _ _ Diameter x Height In grams _ White
Diameter x Height
Diameter x Height

REQUIRED TOOLS & SUPPLIES

Line Neutral

Wire connector

Screwdriver

Screws

INSTALLATION INSTRUCTIONS

Wiring the sensor

Electrical box

Double sided electrical tape

Electrical wires

Turn off the power before wiring and installing the device Power the sensor by connecting the AC Line and Neutral wires from the mains supply to the Line (Black color), and Neutral (White color) from the sensor.

CEILING MOUNT
Mounting sensor on false ceiling
Ceiling mount: Sensor can be installed in the false ceiling using the flush mounted accessory, such as the clips, as given in the steps below
1. Make a hole of 78mm diameter in the false ceiling where the sensor is to be installed and take out the main supply wires

78mm 1

2. Connect the Line (Black) and Neutral (White) wires from the device with the external mains supply wires using wire connectors and terminate the same inside the junction box.
3. Press and hold the spring clips (on both sides of the device) and insert the sensor into the mounting hole. Release the spring clips so that the sensor will fit in and remain intact.
Note
To remove the sensor from the ceiling, hold and pull the sensor down

2
3
Removing Lens
Rotate the lens clockwise to connect to the case and rotate anti-clockwise to dismantle from the case
Rotate the lens clockwise to connect to the case

SURFACE MOUNT

Mounting sensor on false ceiling
1. Position the sensor mounting base to fix and take out the mains wire through the hole given at the mounting base.

2. Mount the base on the selected position using screws

Head: CSK Slotted

Length 38mm

Head Diameter 8.3mm

Screw Diameter 3.7mm

3. To power the sensor, connect the AC Line and Neutral wires from the mains supply to the sensor Line (Black) and Neutral (White) wires using wire connector. Terminate the wires within the sensor mount.

1&2 3

4. Connect the sensor unit case with the Mount base (that is already fixed in step 2) by rotating the case clockwise.
Note
To remove the sensor unit case from the mount base, apply pressure towards ceiling and rotate the sensor case anti-clockwise.

4
WIRING DIAGRAM
Line Neutral

APPLICATION

Driver

AC lines

Controller Light Fixture

Cyrus AM

TROUBLESHOOTING

Lights are not responding to Motion

Check whether the Sensor is powered ON
Check whether the Sensor association configured in the Group is correct

Lights are not responding to Daylight

Check whether the Sensor is powered ON
Check whether the Sensor association configured in the Group is correct
Check whether the Daylight Sensor Settings (for the Sensor displayed under Devices tab) configured is correct

COMMISSIONING
Once powered up, the device will be ready to be commissioned via the Lumos Controls mobile app, available for free download on iOS and Android. To begin commissioning, click the `+' icon from the top of the `Devices' tab. The app allows you to preset certain configurations which will be loaded after the device is added. The pre-configurations made using 'Commissioning Settings' will be sent to the devices being commissioned.
Once commissioned, the device will be displayed in the `Devices' tab and you can configure Sensitivity from the device settings.
Please visit Help center for more details

WARRANTY
5-year limited warranty Please find warranty terms and conditions Note: Specifications may change without notice Actual performance can vary due to end-user environment and application

LUMOS CONTROLS APPLICATION
Download the `Lumos Controls' application from Play Store or App Store OR
Scan the QR codes to download the `Lumos Controls' application

The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by WiSilica Inc. is under license. Other trademarks and trade names are those of their respective owners.

20321 Lake Forest Dr D6, Lake Forest, CA 92630

www.lumoscontrols.com +1 949-397-9330

All Rights Reserved WiSilica Inc

Ver 1.0 Sep 2022



References

Adobe PDF library 16.07 Adobe Illustrator 26.5 (Windows)