Instruction Manual for DMTECH models including: D9000 Series Conventional Detectors, D9000 Series, Conventional Detectors, Detectors
Sep 29, 2022 · INSTRUCTION MANUAL CONVENTIONAL DETECTORS D9000 series Type Characteristics Sensitivity / Class D9000 SR Optical smoke fire detector EN 54-7 D9000 T/A1R Rate of rise heat detector A1R, EN 54-5 D9000 T/A1S Fixed temperature heat detector A1S, EN 54-5 D9000 MSR Combined optical smoke and heat detector A1R, EN 54-5 / EN 54-7
File Info : application/pdf, 2 Pages, 940.92KB
DocumentDocumentINSTRUCTION MANUAL CONVENTIONAL DETECTORS D9000 series Type Characteristics Sensitivity / Class D9000 SR Optical smoke fire detector EN 54-7 D9000 T/A1R Rate of rise heat detector A1R, EN 54-5 D9000 T/A1S Fixed temperature heat detector A1S, EN 54-5 D9000 MSR Combined optical smoke and heat detector A1R, EN 54-5 / EN 54-7 Caution : Read this manual before attempting to install the detector. 1. TECHNICAL DATA Supply voltage 10-30 V DC Current consumption in Standby mode 130 µ Current consumption in Alarm condition 20 m/ 24V DC Time to enter standby mode after reset up to 35s Reset time 2s Degree of protection IP 43 Type of the connecting line to the base 0,5÷1,5 mm2 / two-wire Output in Alarm condition (term. 3) limited to 2 k, negativ Operating temperature range minus 10º ÷ plus 50º Humidity (93 ± 3)% at 40º Dimensions with base Ø 100mm h 52mm Weight 100g 2. INSTALLATION Choose the place (according to the plans of the project) for the installation of the detector; Mount the base with appropriate fixings; Connect the electrical cables according to the attached diagram ( Figure 1); Fig.1 Place the detector base and rotate clockwise till matching markers; If you want to lock detector: Pre remove the key from the base ( Figure 2). Break the plastic at the specified location on the bottom of the sensor ( Figure 3 ). Manufacturer: "DMTech" Ltd., 58 Kliment Ohridski Str., Pleven 5800, Bulgaria, EU, http://dmtech-ltd.com Fig.2 Fig.3 Fig.4 Place the detector on the base and rotate it . If the detector is locked to the base, to unlock it , insert first the key to the specified location (Fig. 4) and rotate the detector counterclockwise; Test the detector to check the correct operation of the LED indication; During normal operation, the LEDs blink every 16 seconds. 3. TESTING AND SERVICE SCHEDULE Testing Apply power; Wait about a minute or until the detector begins to blink; Operate the detector test spray and / or temperature sourse. The two red LEDs must illuminate permanently. Service schedule Visual inspection for mechanical damage and pollution - once a year; Verification of performance - once a year; Prophylactic cleaning - depending on the environment in which it is located. Optical detectors D9000 SR/MSR are software tested and when the detector is contaminated, it is signaled by flashing LEDs for 2 seconds to 2 seconds. D9000 Series detectors are compatible with all conventional power panels, that have met the requirements of a standards EN54. The detectors are available with three types of bases: B 9000 - Standard base; B 9000D - Standard base with mounted diode for fault detection - removed detector; B 9000R - Standard base with relay output 12V for security panels. 4. Warranty obligations The warranty period is 36 months from the date of sale, provided that: the conditions of storage and transport have been followed; release is performed by authorized persons; the requirements for operation stated in this instruction have been abode; defects are not caused by natural phenomena and accidents of the plug socket. Manufacturer: "DMTech" Ltd., 58 Kliment Ohridski Str., Pleven 5800, Bulgaria, EU, http://dmtech-ltd.com