LIFEPAK® 1000 DEFIBRILLATOR
The LIFEPAK 1000 defibrillator from Physio-Control offers flexibility and adaptability for all responders, from first responders to ALS teams. Its rugged design and ease of use make it suitable for various emergency situations.
The Right Tool at the Right Time. Every Time.
The LIFEPAK 1000 defibrillator is designed for a wide range of users and environments. It combines the simplicity of an Automated External Defibrillator (AED) with advanced capabilities for professional responders, enhancing lifesaving outcomes and facilitating patient care transitions.
For first responders, the LIFEPAK 1000 provides critical defibrillation for victims of sudden cardiac arrest. It offers clear on-screen and audio guidance for ease of use.
For ALS-trained professionals, the device offers manual override capabilities, allowing greater control over analysis and shock delivery. Its ECG capabilities provide vital information for treatment protocols and post-event review.
In vehicles or on the scene, the LIFEPAK 1000 is built for durability. BLS-trained responders benefit from its powerful defibrillation (up to 360 joules), long battery life, and rugged construction. The cprMAX™ technology allows configuration to match specific CPR protocols.
Compatibility with other Physio-Control devices ensures a seamless transition of patient care, allowing electrodes to remain on the patient during handoffs.
LIFEPAK 1000 Defibrillator and CODE-STAT 9.0 Data Review Software
Patient and performance data captured by the LIFEPAK 1000 can be easily managed with CODE-STAT 9.0 Data Review Software, aiding in performance review and training.
LIFEPAK 1000 Defibrillator at a Glance
- Rugged Construction: Rigorously drop-tested device with a protective case and bumpers.
- Vehicle Friendly: Designed to withstand vibrations and movement in vehicles.
- Flexible Power Options: Choice between rechargeable Lithium-ion (Li-ion) or non-rechargeable Lithium-Manganese Dioxide (Li MnO2) battery.
- 360 Joules: Escalates defibrillation power up to 360J.
- cprMAX™ Technology: Minimizes CPR interruptions by allowing compressions during AED charging.
- CPR Countdown Timer: Provides guidance for CPR intervals based on system protocol.
- ECG Capability: Available 3-lead ECG function.
- Shock Counter: Digitally records and displays delivered shocks.
- Large Display: Easy-to-read LCD screen for at-a-glance information.
- Compatible Technology: Electrodes are compatible with all other LIFEPAK defibrillators and monitors.
- Programmable: Settings can be adjusted to match team CPR and resuscitation protocols.
- Easy-To-Use AED: Loud voice prompts and on-screen graphics guide users.
cprMAX Technology
The exclusive cprMAX technology allows users to choose CPR settings that best suit patient and protocol requirements. The pre-shock CPR option minimizes pre-shock pauses by enabling compressions during AED charging, aligning with clinical data emphasizing the importance of high compression fraction for survival.
LIFEPAK TOUGH™
Built for harsh environments, the LIFEPAK 1000 is Physio-Control's most durable AED, withstanding rigorous drop-testing and featuring an IP55 rating for protection from external elements.
360 Joules
The LIFEPAK 1000 can escalate energy up to 360J, offering higher efficacy for difficult-to-defibrillate patients, consistent with 2010 AHA Guidelines.
ALS Hand-off
The LIFEPAK 1000 facilitates a smooth transition to ALS care teams with its user-friendly interface, shock counter, available 3-lead ECG, and compatible electrodes used across Physio-Control ALS monitors.
Getting Responders Ready with Training Tools
Physio-Control offers comprehensive training solutions:
- Trainer 1000: Provides realistic training with simulated analysis, energy delivery, and CPR intervals without using a live device.
- Training Simulation Package: Includes a patient simulator, spare battery, and training electrodes for hands-on AED skill practice.
- AED Challenge: An interactive online tool for AED/CPR skills refresher training with real-life scenarios and administrator tracking.
Committed to Service
Physio-Control provides industry-leading technical support with a large network of representatives available 24/7 to assist with device issues.
Meets Your Needs
The flexible LIFEPAK 1000 defibrillator empowers first responders with essential lifesaving tools and provides advanced responders with the information and capabilities needed to improve patient outcomes.
Contact your Physio-Control sales representative or call 1.800.442.1142 for more information.
Hospitals
The LIFEPAK 1000 can be integrated into a comprehensive AED solution for healthcare facilities. Contact Physio-Control for a free Heart Safe Hospital Assessment to align cardiac response with current guidelines.
Physio-Control Family of Products
Defibrillators/Monitors
- LIFEPAK CR® Plus Automated External Defibrillator: Designed for first responders, offering advanced technology and ease of use.
- LIFEPAK® 15 Monitor/Defibrillator: The standard for ALS teams, featuring advanced clinical technologies, escalating energy up to 360J, and an upgradable platform.
- LIFEPAK® 20e Defibrillator/Monitor with CodeManagement Module®: Combines AED function with manual capabilities for advanced therapeutic care, with optional waveform capnography and wireless connectivity.
CPR Assistance
- LUCAS® Chest Compression System: Provides effective, consistent, and uninterrupted chest compressions according to AHA Guidelines.
- TrueCPR™ Coaching Device: Optimizes manual CPR performance with real-time and post-event feedback on compression depth.
Information Management
- LIFENET® System: A secure, web-based platform for reliable access to clinical information, improving patient care and operational efficiency.
- CODE-STAT™ Data Review Software: A retrospective analysis tool for easy access to data, reports, and post-event review.
Specifications
Waveform
Biphasic truncated exponential with voltage and duration compensation for patient impedance*.
Energy Sequence
User configurable, 150 joules-360 joules. Default settings: 200, 300, 360 joules. 360 joules for subsequent shocks.
Charge Time
With new, nonrechargeable battery pack: 200 joules in less than 7 seconds; 360 joules in less than 12 seconds.
3-Wire (Lead II) Monitoring Capability
Requires purchase of 3-wire (Lead II) monitoring cable and LIFE-PATCH® electrodes.
Device Software
Field upgradeable.
Infant/Child Reduced Energy Defibrillation Electrodes
Reduces selected energy by a factor of 4. For use with children up to 8 years of age or 25 kg (55 lbs).
Safety Classification
Internally powered equipment IEC 60601-1.
Electrical Protection
Input protected against high voltage defibrillator pulses per IEC 60601-1.
Modes
- AED: Basic user operation.
- Manual: Advanced user operation.
- ECG: ECG display capability with 3-wire ECG cable.
- Setup: Device configuration.
- Data Transfer: Patient data transfer.
- Auto Test: Daily automatic hardware and software tests.
Controls
On/Off, Shock, Menu, Two (2) configurable soft keys.
User Defined Options
- Device ID
- Energy Sequence (150-360 joules)
- Flexible Energy
- Auto Analyze (configurable: auto, after first shock, prompt)
- CPR Time (Post shock or after no shock advised): 15, 30, 45, 60, 90, 120, 180 seconds.
- Device Date/Time
- Voice Prompt Volume
- ECG Display (On/Off for AED mode)
- Motion Detection (On/Off, default On)
- Service Alert (Audio alarm, configurable On/Off)
- Manual Access (for devices with ECG display)
- cprMAX Technology Settings: Initial CPR, Pre-shock CPR, Stacked Shocks (On/Off), Pulse Check (Always, After Every NSA, After Second NSA, Never)
Display
Backlit LCD displaying shocks delivered, elapsed time, heart rhythm, and optional ECG.
- Size: 120 mm (4.7 in) + 89 mm (3.5 in).
- Frequency Response: 0.55 Hz to 21 Hz (-3 dB), nominal.
- ECG Option: Waveform Sweep Speed - 25 mm/sec; Waveform Viewing Time - Minimum 4 seconds; Waveform Amplitude - 1 cm/mV, nominal; Heart Rate - 20 to 300 BPM digital display.
ECG information received from adult and Infant/Child electrodes (anteriorlateral or anterior-posterior positions). A 3-wire cable can be used for ECG monitoring (Lead II).
Environmental
- One Hour Operating Temperature: -20 to 60 °C (-4 to +140 °F).
- Operating Temperature: 0° to 50 °C (32° to 122 °F).
- Storage Temperature: -30 to 60 °C (-22 to 144 °F) with battery and electrodes (max 7 days).
- Atmospheric Pressure: 575 hPa to 1060 hPa.
- Relative Humidity: 5 to 95% (non-condensing).
- Dust/Water Resistance: IP55 with battery and REDI-PAK™ electrodes installed.
- Bump: 15 g, 1000 bumps.
- Shock: 40 g peak, 15-23 ms.
- Drop: 1 meter drop on each corner, edge, and surface.
- Vibration: Random vibration test - 3.15 g rms for 1 hour per axis.
- EMI: Radiated and Immunity compliance per IEC 60601 standards.
Effect Dissemination and Communication
- Memory Capacity: Dual patient storage, minimum 40 minutes ECG for current patient, summarized data for previous patient.
- Report Types: Continuous ECG, summary (critical resuscitation events and waveforms), event log report, test log report.
- Capacity: Minimum 100 time-stamped event log entries.
- Data Review: CODE-STAT™ 6.1 Medical Informatics System, DT Express™ 2.1 Information Management System or higher.
- Communications: Infrared wireless transfer to personal computer.
Battery and Realities/ES Display
Nonrechargeable Battery:
- Type: Lithium Manganese Dioxide (Li/MnO2), 12.0 V, 4.5 Ah.
- Capacity: Typically 440 200-joule discharges or 1030 minutes of operating time.
- Weight: 0.45 kg (1.0 lb).
- Shelf Life: 5 years at 20-30°C, providing 48 months of standby life.
- Standby Life: 5 years.
- Low Battery Indicator: At least 30 200-joule shocks or 75 minutes of operating time remaining.
Rechargeable Battery:
- Type: Lithium-ion, 11.1 V, 4.8 Ah, 53 Wh.
- Capacity: Typically 261 200-joule discharges or 608 minutes of operating time.
- Battery Charging Time: Within 4.5 hours.
- Weight: 0.45 kg (1.0 lb), maximum.
- Standby Life: 6 months.
- Low Battery Indicator: At least 30 200-joule shocks or 75 minutes of operating time remaining.
Battery Charger:
- Supported Battery: Lithium-ion Rechargeable Battery, 11.1 V, 4.8 Ah, 53 Wh.
- Electrical: External Power Supply: 100-240VAC, 50/60Hz.
- Temperature: Operating: 0-40 °C; Storage: -30 to 70 °C.
- Charge Time: Within 4.5 hours.
- Dimensions: Length: 270 mm, Width: 97 mm, Height: 92 mm.
- Weight: 0.5 kg.
Physical Characteristics
- Height: 8.7 cm (3.4 in).
- Width: 23.4 cm (9.2 in).
- Depth: 27.7 cm (10.9 in).
- Weight: 3.2 kg (7.1 lbs) with one set of REDI-PAK electrodes and one nonrechargeable battery.
References
- Christensen J, Andrusiek D, Everson-Stewart S, et al. Chest compression fraction determines survival in patients with out-of-hospital ventricular fibrillation. Circulation. 2009; 120:1241-1247.
- Stiell I, Walker R, Nesbitt L, et al. "The BIPHASC Trial: a randomized comparison of fixed lower versus escalating higher energy levels for defibrillation in out-of-hospital cardiac arrest." Circulation. 2007; 115:1511-1517.
- Koster R, Walker R, Chapman F. Recurrent ventricular fibrillation during advanced life support care of patients with prehospital cardiac arrest. Resuscitation. 2008; 78:252-257.
- 2016 American Heart Association guidelines for cardiopulmonary resuscitation and emergency cardiac care science. Circulation. 2010.
All claims valid as of June 2015.
For further information please contact your local Physio-Control representative or visit our website at www.physio-control.com
Physio-Control Headquarters
11811 Willows Road NE Redmond, WA 98052 USA
Tel 4256674000 Fax 4258674121 www.physio-control.com
Physio-Control Operations Netherlands B.V.
HQ Europe, Middle East & Africa UP Office Building Piet Heinkade 55, 1019 GM Amsterdam NL
Tel +31 (0)20 7070560 Fax +31 (0)20 3391194 www.physio-control.com
Physio-Control UK Sales Ltd
Concorde House Trinity Park, Solihull Birmingham B37 7UG United Kingdom
Tel +44 (0)808 2560094 Fax +44 (0)808 1890337
Physio-Control Australia Pty Ltd
Suite 4.01 15 Orion Road Lane Cove NSW 2066 Australia
Toll Free Tel 1800987982 Toll Free Fax 1800890892