Instruction Manual for Lincat models including: LCOT, LCOS, LCOXL, Lynx Electric Convection Ovens
Lynx Electric Convection Ovens ... Read these instructions carefully before using this product, paying particular ... KEEP THIS MANUAL FOR FUTURE REFERENCE ...
Lincat LCOS - Lynx 400 Slim Convection Oven Specification Sheet
File Info : application/pdf, 8 Pages, 239.51KB
DocumentDocumentInstallation, Operating and Servicing Instructions Lynx Electric Convection Ovens LCOT, LCOS, LCOXL Please make a note of your product details for future use: Date Purchased:_________________________ Model Number:__________________________ Serial Number:__________________________ Dealer:_________________________________ _______________________________________ IS 733 ECN 4842 Page 1 of 8 CONTENTS Important Information 2 Warnings and Precautions 3 Technical Data 3 Checklist of Enclosures 3 Installation and Commissioning 3 Operating Instructions 5 Cleaning 6 Servicing, Maintenance and Component Replacement 7 Fault Finding 7 Spare Parts List 7 Service Information and Guarantee 8 IMPORTANT INFORMATION Read these instructions carefully before using this product, paying particular attention to all sections that carry warning symbols, caution symbols and notices. Ensure that these are understood at all times. WARNING! This symbol is used whenever there is a risk of personal injury. CAUTION! This symbol is used whenever there is a risk of damaging your Lincat product. NOTE: This symbol is used to provide additional information, hints and tips. KEEP THIS MANUAL FOR FUTURE REFERENCE IS 733 ECN 4842 Page 2 of 8 WARNINGS AND PRECAUTIONS This appliance must be installed, commissioned and serviced by a qualified person in accordance with national and local regulations in force in the country of installation. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified person. Ensure that the plug/socket is accessible at all times. Strip plastic coating and clean the appliance before use. During operation parts may become hot - avoid accidental contact. Disconnect this appliance before servicing, maintenance or cleaning. TECHNICAL DATA Model LCOT LCOS LCOXL Height (mm) 520 520 605 Width (mm) 495 405 670 Depth (mm) 570 570 570 Weight (kg) 29.3 28.4 49.6 CHECK LIST OF ENCLOSURES Instruction manual 1 Wire shelves LCOT, LCOS 2 Wire shelves LCOXL 3 Feet LCOXL 4 INSTALLATION AND COMMISSIONING This appliance must be earthed. An equipotential bonding terminal is provided to allow cross bonding with other equipment. If replacing the plug connect the terminals as follows: Green and Yellow wire Earth E IS 733 ECN 4842 Page 3 of 8 Blue wire Brown wire Neutral N Live L Supply cords shall be oil resistant, sheathed flexible cable not lighter than ordinary polychloroprene or equivalent elastomer sheathed cord (code 60245 IEC 57) Install this appliance on a level surface ensuring all vents are unobstructed. Install this appliance on a level surface ensuring all vents are unobstructed. Any partitions, walls or furniture must be of non-combustible material. Minimum distances A 100mm B 1000mm see Fig 1. B A A Fig 1 IS 733 ECN 4842 Page 4 of 8 Power Ratings Model kW LCOT, LCOS, LCOXL 2.5 Amps 10.9 OPERATING INSTRUCTIONS Only qualified or trained personnel should use this appliance. Connect the appliance to an electricity supply and switch on at the socket. Press the switch on the appliance to the `On' position the switch and interior light illuminate, and the fan operates. Turn the temperature control knob to the desired setting the amber neon illuminates and extinguishes when temperature is reached. During operation, the amber neon will periodically illuminate as the element cycles. Adjacent to the temperature control is a 55 minute mechanical timer. This appliance is fitted with a safety thermostat, which will cut power to the appliance under fault conditions. If the switch illuminates but the appliance does not heat up, the safety thermostat may need re-setting. This is achieved by pressing the red button located as shown in Fig 2. Note that in the event of the safety thermostat operating, the appliance must be allowed to cool before it can be re-set. IS 733 ECN 4842 RESET BUTTON Fig 2 Page 5 of 8 CLEANING Do not use a water jet or steam cleaner, and do not immerse this appliance. Clean all panels with warm water and mild detergent. Do not use abrasive materials, and do not use caustic or chloride based cleaners. Dry with a soft cloth. If required, the shelf supports in the oven may be removed to allow a thorough clean of the interior. The shelves are bolted in place tightly during transport to avoid damage. On delivery, back off the 3 bolts holding each shelf by 2mm. This will allow the shelf supports to be pushed upward slightly and then lifted out through the keyhole slot provided. On re-fitting, the bolts do not need to be retightened, which will allow the shelf supports to be clipped in and clipped out as necessary in the future. 1. Back off bolts 2mm IS 733 ECN 4842 Fig 3 Page 6 of 8 SERVICING, MAINTENANCE AND COMPONENT REPLACEMENT Door inner glass: Slide glass up to clear side brackets and remove from top. To replace the glass, reverse the procedure. Light bulb: Lever off the glass cover using a small flat bladed screwdriver. Unscrew bulb. To replace the bulb, reverse the procedure. Door seals: These simply hook out of the holes. Hook out to remove and replace by hooking the new seal into position. All other servicing, maintenance and component replacement on this appliance should be carried out by one of our recommended service engineers. FAULT FINDING Please refer to the Service Help Desk number on the final page of this manual. SPARE PARTS LIST Part Number BU55 EL232 FA106/S FE37 FE10 GA75 GL707 GL709 GL711 KN250 LA10 LE14 NE42 PL202 SE35 SE94 SE95 SE96 SH139 SH140 SH141 SW69 TH46 TH203 TI37 Description Door hinge bush Element Fan Foot LCOT, LCOS LCOXL Fan gasket Door inner glass LCOT Door inner glass LCOS Door inner glass LCOXL Control/Timer knob Lamp Clear cover for On/Off switch Amber neon Mains cable Door seal top LCOT or Door seal side LCOXL Door seal side LCOT, LCOS Door seal top - LCOS Door seal top - LCOXL Shelf LCOT Shelf LCOS Shelf LCOXL Switch Control thermostat Safety thermostat Timer IS 733 ECN 4842 Page 7 of 8 SERVICE INFORMATION For help with the installation, maintenance and use of your Lincat equipment, please contact our service department: UK: 01522 875520 For non-UK customers, please contact your local Lincat dealer All service work, other than routine cleaning should be carried out by one of our authorised service agents. We cannot accept responsibility for work carried out by other persons. To ensure your service enquiry is handled as efficiently as possible, please tell us: Brief details of the problem Product code Type number All available on serial plate Serial number Lincat reserve the right to carry out any work under warranty, given reasonable access to the appliance, during normal working hours, Monday to Friday, 08:30 to 17:00. GUARANTEE This unit carries a comprehensive UK mainland 2 year warranty. The guarantee is in addition to, and does not diminish your statutory or legal rights. The guarantee does not cover: Accidental damage, misuse or use not in accordance with the manufacturer's instructions Consumable items (such as filters, glass, bulbs, slot toaster elements and door seals.) Damage due to incorrect installation, modification, unauthorised service work or damage due to scale, food debris build-up, etc. The manufacturer disclaims any liability for incidental, or consequential damages. Attendance is based on reasonable access to the appliance to allow the authorised technician to carry out the warranty work. Service calls to equipment under warranty will be carried out in accordance with the conditions of sale. Unless otherwise specified, a maximum of 15 minutes of administrative time, not spent directly carrying out servicing work, is provided for within the warranty. Any requirement for staff attending the call to spend greater time than 15 minutes due to administrative requirements, such as on health and safety risk assessments, will be chargeable at the prevailing rate. IS 733 ECN 4842 Page 8 of 8Microsoft Word 2013 Microsoft Word 2013