UC350 Series Quick Installation Guide

DINSTAR

UC350 Series Quick Installation Guide

Руководство по быстрой установке Dinstar UC350 и UC350 Pro (1.16 MB)

IP АТС Dinstar UC350-8S8O, 200 одновременных соединений, IVR, 8 х FXO, 8 х FXS, 2 х Gigabit Ethernet - Орел

IP АТС Dinstar UC350-4S4O, 120 одновременных соединений, IVR, 4 х FXO, 4 х FXS, 2 х Gigabit Ethernet - Екатеринбург


File Info : application/pdf, 14 Pages, 1.16MB

PDF preview unavailable. Download the PDF instead.

UC350&UC350 Pro Quick Installation Guide
Quick Installation Guide
UC350 UC350 Pro
THANKSFORCHOOSINGDINSTAR'S PRODUCTS!
 Please readthis guide carefully bef0o7re55in-s6t1a9lli1n9g9t6he6device. If you need any technical Tseulpw:p+wo8rw6t,7.Pd5lie5na6sst1ea9rc1.oc9nn9t6a6ct us.
Email: support@dinstar.com Web: www.dinstar.com

1 Models and Interfaces

MCU Board

User board (FXO, FXS, FXU, DTU

UC350 UC350 Pro

2*Network Ports 1*USB 2.0 Port 1*Console Port
4*Network Ports 2*USB 2.0 Ports 1*USB 3.0 Port 1*Console Port 1*HDMI Port

FXS Board: 2*RJ45 with 8 FXS FXO Board: 2*RJ45 with 8 FXO FXU Board: 2*RJ45 with 4 FXS and 4 FXO DTU Board: 4*RJ45 with 4 E1/T1 Ports

2 Description of Indicators

Type MCU board

Indicators Definition

PWR

Power Indicator

RUN

Running Indicator

PWR FXS/FXO/ FXU User Board RUN

Power Indicator
Running Indicator

FXS/FXO

FXS/FXO Indicator

PWR DTU User Board
RUN

Power Indicator
Running Indicator

Status OFF

Description There is no power supply or the power supply is abnormal

ON Flashing ON

The device is powered on The device is initialized successfully and running normally The system is initializing

OFF ON

The device is not running normally The power supply is normal

OFF
Fast Flashing Slow Flashing
ON

The power supply is not normal The system is starting up Part of the port registered successfully The FXS port is in off-hook (in-use) status

OFF
OFF
ON Slow Flashing ON OFF

The FXS port is in on-hook status There is no power supply or the power supply is abnormal The device is powered on
The device is initialized successfully and running normally The system is initializing The device is not running normally

E1/T1

E1/T1 Indicator

ON OFF

E1/T1 line is connected E1/T1 line is disconnected

3 Indicators and Ports

UC350 Front View:

D

DF

F

T

TX

X

U

PORT 0 PORT 1 PORT 2 PORT 3

UU

U

MCU 1 SLOT2 SLOT3 MCU 0 SLOT0 SLOT1

M C U

MF CX UO

FF XX OS

F X S

Main Control Board

M C U
Power Indicator Running Indicator

USB
Network Port for Service

M C U
Reset Port Console Port Network Port for Management

Back View:

User Board Slot Expandable E1/T1/FXS/FXO ports

/

/

Grounding Lug Power Switch Power Jack
UC350 Pro Front View:

Power Switch Power Jack

MCU 1 SLOT2 SLOT3 MCU 0 SLOT0 SLOT1

Main Control Board

Reset Port

USB3.0 USB2.0 HDMI

User Board Slot Expandable E1/T1/FXS/FXO ports

Power Indicator Running Indicator

Console Port

Network Port for Management Network Port for Service

Back View:

/

/

Grounding Lug Power Switch Power Jack

Power Switch Power Jack

4 Installation Attentions
The adapter of the gateway accepts DC220V 10A dual power input. Please ensure it is workable and safe.
To reduce the interference to telephone calls, please separate power supply cables from telephone lines.
To guarantee running of the gateway as usual, please make sure that there is sufficient network bandwidth.
For better heat dissipation, please place the gateway on a level surface and ensure space for other devices.

5 Installation Instructions
Connect with Power Input

Connect with Grounding Lug

/
AC100-240V

/
Grounding Cable Grounding Lug

Connect telephone line to the FXS port and connect PSTN line to the FXO port

F X O
Converter

F X O
PSTN Line

F X S
Converter

F X S
Telephone Line

PSTN

Analog Phone

Connect to E1/T1 Ports

D

D

T

T

U

PORT 0 PORT 1 PORT 2 PORT 3

U

E1/T1 Cable

E1/T1 Cable

Converter

RJ48 BNC

Rx

Tx

Coaxial Line

PSTN
PBX or E1/T1 Board with RJ48 Interface

Connect to FXS ports and FXO ports

F X U
Telephone Line
Analog Phone

F X U
PSTN Line PSTN

Note: Ports 0-3 are FXS, and ports 4-7 are FXO.

Connect with Ethernet
Network Port for Service

Network Port for Management

192.168.12.1 Network Cable

192.168.11.1 Network Cable

IP Network

Router/Switch

192.168.11.XXX

PC

Switch

Note: The UC350's default network port for management is the GE1 port, and the UC350 Pro's default network port for management is the GE3 port.

6 RJ45 Wire Sequence

UC350 series products support RJ45 Interfaces for FXS/FXO connections. One RJ45 cable can be split into four pairs of RJ11 interfaces. The outlook wire sequence of RJ45 cable is shown as follows:

7 Modify PC's IP Address
To log in to the Web Management System of the device, firstly, you need to modify the IP address of the PC that is used to access the device and to make it at the same network segment as the device's network port of management.

1 On the PC, click `Network (or Ethernet) 2 Double-click `Internet Protocol Version 4

 Properties'.

(TCP/IPv4)'.

3 Select `Use the following IP address', and then enter an available IP address `192.168.11.XXX' which is at the same network segment with `192.168.11.1'.

8 Login Web GUI
Open a browser and enter the default IP address of the network port for management: https://192.168.11.1. Enter the username and password to log into the system. The username and password are admin/admin@123#. Note: The UC350's default network port for management is the GE1 port, and the UC350 Pro's default network port for management is the GE3 port. New devices can only modify the IP address through the management port. The UC350 Pro login interface is shown below:
9 Check Network Status
Check the network status on the "System->Network" page.

10 Modify Network Configuration
You need to modify the IP address of the network ports for service so that the ports and the upstream network are in the same network segment.
Firstly, you need to physically connect the device's network port for management. Then log into the device by entering the IP address of the network port for management in the web browser and click "System->Network" to configure the IP address of the network ports for service. Click "Save" and "Reset" to make the settings take effect.

11 Create SIP Extensions
Click "Extension  Call Group->SIP Extension" to create the SIP extension: add/delete/disable/enable, etc. UC350 Pro supports batch add or import account files. Note: when add the extension, the profile should be chosen as the corresponding one.
After setting, you need to click "apply" to make the settings take effect. The registration status of SIP extension can be checked on the "Extension  Call Group->SIP Extension->Status" page. If the status of a newly added SIP account is "registered", it means that the device accepts the registration of the extension. If the status of the SIP account is "unregistered", it means that the device rejects to register the extension.

12 Add Trunk
SIP Trunk
SIP trunks are used to connect other SIP terminals or service providers. When adding a SIP trunk, you should choose corresponding SIP profile based on your current network. The SIP trunk supports UDP/TCP/TLS. You can create a new SIP trunk on the "Trunk  Route->SIP Trunk->Setting" interface, and SIP trunk status can be checked under "Trunk  Route->SIP Trunk->Status" interface.

FXO You can also create Trunk/FXO. It is an alternative to support calls go through or from PSTN.
E1/T1 You can set up ISDN PRI/SS7 connections via digital E1/T1 ports. Please be sure that the E1/T1 physical connection is well connected, and PRI status is in up and active status before configuring the call routing.

13 Configure Inbound / Outbound Route
On the "Trunk  Route->Route" interface, you can configure routes for incoming calls and outgoing calls, and select the call Source and Destination addresses for the route. When the configured route is activated, the system will match the route based on the priority index. The key configuration of route is at "condition" part. Here, you can configure the route based on the Caller/Called Number prefix and time.

14 Regular Expression

Caller/Called number prefix supports regular expression Regular Expression Syntax

Matches the starting position in a number string. For example, ^134 matches the

^

numbers starting with 134.

$

Matches the ending position of a string. For example, 2$ matches the numbers ending with 2.

|

Separates alternate possibilities. For example, 2|3|4 means 2,3 or 4.

\

Marks the next character as a special character, a literal, a back reference, or an octal escape.

Matches a single character that is contained within the bracket. For example, [1

[ ]

23] matches 1, 2, or 3. [0-9] matches any digit from "0" to "9".

[^]

Matches any one character except those enclosed in [ ]. For example, [^9] matc

hes any character except 9.

.

Matches any single character except the newline character. For example, 3.4 m

atches 314, 324, 334, 344.

?

Indicates there is zero or one of the preceding element.

For example, colour matches both color and colour.

Indicates there is zero or more of the preceding element. For example, ab*c ma

*

tches ac, abc, abbc, abbbc, and so on.

+

Indicates there is one or more of the preceding element. For example, ab+c mat ches abc, abbc, abbbc, and so on, but not ac.

\d

Marks any digit, equal to [0-9 ].

/D

Marks any character that is not a digit, equal to [^0-9 ].

/s

Marks any blank character such as a space or a tab.

/S

Marks any character that is not a blank character.

Examples of Regex Syntax:

^0755 ^0755|^8899|^0110 ^[1][358][0-9]{9}$

Matches the phone numbers with starting digits of 0755.
Matches the phone numbers with starting digits of 0755, 8899 or 0110.
Matches the phone numbers with the first digit as 1, the second digit as 3, 5 or 8, the left nine digits as any of 0 to 9.

15 Basic Operation
Dial *114# to query the telephone number of a FXS port; Restart the device: 1 Dial *111# to restart the device; 2 Click "system->Reboot" menu to perform reboot.
16 More Details
This document only provides instructions for quick installation and basic configuration. For detailed configuration and parameter explanations, Please refer to User Manual or ask for technical support.
IP COMMUNICATION SOLUTIONS
Shenzhen Dinstar Co., Ltd. Web: www.dinstar.com



References