User Manual for SIEMENS models including: FSD901-U2, FSD901-R2, FSD901-U3, FSD901-R3, FSD901-U2 Floor Repeater Display for Fire Detection System, Floor Repeater Display for Fire Detection System, Repeater Display for Fire Detection System, Fire Detection System, Detection System
Siemens FSD901-U2 FSD901-R2 FSD901-U3 FSD901-R3 Floor Repeater Display, Product Manual - Fire Alarm Resources - Free fire alarm PDF manuals, documents, installation instructions, and technical specifications
File Info : application/pdf, 4 Pages, 2.09MB
DocumentDocumentFSD901-U2/ FSD901-R2/ FSD901-U3/FSD901-R3 Floor Repeater Display Product Manual Overview Characteristic A6V10333726_c_en_-2020-02-05 The floor repeater display is an indication and operation unit in a fire detection system with the following functions: Indication of events Operation l Alarm l Scrolling through lists l Trouble l Reset l Supervisory l Acknowledge l Status l Unsilence l Silence The display on the floor repeater terminal is synchronized with the fire control panel and displays the same event texts. l Small floor repeater operating, and display panels applied in FC2005/FC901 fire detection system l Large backlight LCD display(160X64) l Communication with controller via RS485 (individual addressing) l Additional 24 VDC power supply necessary l In total, up to 8 FSD can be connected to a fire control panel l Access control by key l Flat, elegant housing Smart Infrastructure firealarmresources.com Function Application l Display of alarms, troubles, supervisory and status event l Same message layout as the fire control panel l With the navigation keys an indicated list in the display can be scrolled through l The internal buzzer can be switched off manually by pressing button "Acknowledge" l Reset events displayed on the FSD l Silence and unsilence User Level A6V10333726_c_en_-- Fig.1 Front view No. Name 1. LCD 2. Alarm 3. Four-way button 4. Power 5. Trouble 6. Ground Fault 7. Silenced 8. Supervisory 9. Audibles on 10. <Reset> 11. <Acknowledge> 12. <Unsilence > 13. <Silence > 14. Lock Function Display of alarms, troubles, supervisory and status Light up in case of fire For menu navigation Light up when power supply is normal Light up in case of trouble event Light up in case of ground fault event All activated silenceable devices are silenced Light up in case of supervisory event Light up when NAC or silenceable device is activated Clear all events Acknowledges unacknowledged events All silenced devices are activated again Silence all activated silenceable devices Set user access level by key FSD floor repeater display control access right through lock on door. There are two user levels for access right: User level Lock key position L0 L1 The operation items for L0/L1 are listed as below: Items L0 L1 View real time events Acknowledge - Reset - Silence - Unsilence - Lamp test - 2 firealarmresources.com Operation Task View real time events Lamp test Acknowledge or reset events Unsilence devices Silence devices Address and Baud Rate Operation 1. Press "" / "" to navigate a real time event. 2. Press "" to return to first event. Press both "Silence" and "Unsilence" button for 5s to do lamp test. Press "Acknowledge" or "RESET". Press "Unsilence", all silenced devices are activated again. Press "Silence", silence all activated silenceable devices. 8-digit Dip-switch S1 is used for setting the FSD901 address and Baud Rate Setting. The first 1-4 digits is for setting the FSD901 address 1-8, the 7-8 digits is for setting RS485 communication baud rate. The 5 and 6 digits are reserved for future use. DIP switch DIP switch Address 1 2 3 4 Baud Rate 7 8 1 On Off Off Off 9600 bps Off Off 2 Off On Off Off 19200 bps On Off 3 On On Off Off 38400 bps Off On 4 Off Off On Off 115200 bps On On 5 On Off On Off 6 Off On On Off 7 On On On Off 8 Off Off Off On FC2005 and FC901 can only support 19200 bps, other options reserve for future usage. EOL Resistor Installation 2-digit Dip-switch S20 is used for setting EOL resistor of RS485. 1 and 2 OnInternal EOL resistor is connected 1 and 2 OffInternal EOL resistor is disconnected For RS485 Class A, loop mode, no EOL resistor is needed. For RS485 Class B, stub mode, internal EOL resistor of the repeater display at the end of RS485 must be connected. Fig 2 Dimension (mm) 3 Note: · · Fig 3 Connection Point G is not used for any connection. Power in from the non-resettable auxiliary power output on panel. firealarmresources.com A6V10333726_c_en_-- Fig 4 Fig 5 1. Insert the loop line and external power wire through the floor repeater display. 2. Mark the position for the 4 installation holes on flat wall (Fig. 2), drill the holes, put expansion bolts in and insert the screws leaving a small gap for hanging the display. 3. Hang the floor repeater display over those screws through installation holes. 4. Open the front panel (Fig. 4/5), tighten the screws and make sure the display is fixed firmly. 5. Connect cables to terminals referring to the connection diagram (Fig. 3). Correctly set the internal 120 EOL resistor referring to the section "EOL Resistor". 6. Close the front panel. FSD connects to separate power supply, which needs to be UL Listed for Fire Safety Use and Power Limited. Dimension (mm) Technical data Operating voltage Operating current (quiescent) Activation current Operating temperature Humidity Communication protocol Connection terminals Color Operating location 24 VDC nominal / 19...28 VDC 60 mA 70 mA 0...+49 °C 93% rel. UFP (RS485-BUS) 14-18 AWG Black / Red Indoor / dry Details for ordering Type FSD901-U2 FSD901-R2 FSD901-U3 FSD901-R3 Material No. S54433-C102-A4 S54433-C102-A3 S54433-C102-A1 S54433-C102-A2 Part No. 100935670 101061934 101061935 100935673 Designation Desigo system display (black) Desigo system display (red) Cerberus system display (bl) Cerberus system display (red) Weight 1.5 kg 1.5 kg 1.5 kg 1.5 kg Issued by Siemens Industry, Inc. Smart Infrastructure 8 Fernwood Road Florham Park, NJ 08932 Tel. +1 973-593-2600 www.sbt.siemens.com/FIS Doc No. A6V10333726_c_en_-- © Siemens Industry, Inc., 2019 Technical specifications and availability subject to change without notice 100935693 firealarmresources.com A5Q00041959