User Manual for TELRAN models including: 560756 Standalone Access Control, 560756, Standalone Access Control, Access Control, Control
Proximity Reader Stainless Steel Cover, IP54, Terminal Block
S tandalone A c c es s C ontrol 123 456 789 *0# Us er M anual P leas e r ead t he u s er m anual c arefully b efore i ns tallation. INTR ODUC TION This product is a contactless EM proximity card standalone access control. It adopts zinc-alloy case, anti-vandal and anti-explosion, 2,000 user capacity and supporting access by card, card + PIN, card or PIN. It can be installed on 86x86mm mount box. F eatures a nd B enefits Zinc-alloy housing, anti-vandal, anti-explosion Waterproof, conforms to IP 54 User capacity: 2000 Length of PIN: 4 8 digits Wide voltage input: DC 10-24V Supporting block enrollment with cards sequentially numbered Pulse Mode, Toggle Mode Can be installed on 86mm×86mm box, very easy to install Admin can add/delete admin cards, making add/delete cards rapidly. S pec ific ations Operating Voltage 10-24V DC Working Current 80mA Weatherproof IP54 Read Range 6cm User Capacity 2000 Card type EM Card Card Frequency 125KHz Lock Output Load 2A Operating Temperature -40°C+70°C,(-40°F158°F) Operating Humidity 10%98%RH Dimensions L110xW76xH22mm(Wide) Unit Weight 436g Shipping Weight 500g 1 Packing L is t 123 456 789 *0# Wall Anchors Self Tapping Screws Admin Add Card Admin Delete Card Admin Cards Screw Driver Diode 1N4004 (For relay circuit protection) INS TAL L ATION Remove the back cover from the unit with screw. Drill hole on the wall according to the back size of the machine and fix the back cover to the wall. (or fix the back cover firmly to the 86cm×86cm box) Thread the cable through cable hole, connect related cable. For the un-used cable please separate with insulating tape. After wiring, install front casing to the back casing and fix well. 80mm40mm 60mm 2 Wiring Wire C olor Green Brown White Black Red Yellow F unc tion NC COM NO GND DC+ OPEN Notes Relay NC Relay COM Relay NO Negative Pole 10-24V DC Power Input Connect to Exit button and the Exit button is connected to GND S ound a nd L ight I ndic ation Operation S tatus L ight Stand by Red light bright Enter programming mode Red light shines In the programming mode Open lock Operation failed Orange light bright Green light bright B uzzer One beep 3 beeps F ac tory D efault s ettings a nd a dd a dmin c ards Power off, press exit button, power on, release it until hear two beeps. Swiping two cards, the first card is "Admin Add Card", the second card is "Admin Delete Card", then the device will be in standby mode. Resets to factory default setting and adding admin cards are successful. If you don't need to add admin cards: Power off, press exit button, power on, release it until hear two beeps, and the orange LED turn on. Waiting for ten seconds, there is a beep and it will be in standby mode. Resets to factory default setting is successful. Reset to factory default, the users' information won't be deleted. S TANDALONE M ODE C onnec tion D iagram S pec ial P ower S upply f or a c c es s c ontrol s ys tem 3 NO White NC Green COM GND Brown Black DC+ Red OPEN Yellow + Exit Button - C ommon p ower s upply Attention: Install a 1N4004 or equivalent diode is needed when use a common power supply, or the reader might be damaged. (1N4004 is included in the packing). NO NC COM GND DC+ OPEN White Green Brown Black Red Yellow Exit Button 10-24V DC Power A d d /D e le te U s e r s b y A d m i n C a r d Using Admin Cards to add delete card users Add users Step 1: Read Admin Add Card Step 2: Read user cards (Repeat step 2 for additional user cards) Step 3: Read Admin Add Card again to end Delete users Step 1: Read Admin Delete Card) Step 2: Read user cards (Repeat step 2 for additional user cards) Step 3: Read Admin Delete Card again to end 4 Quic k S tart a nd O peration Quic k S ettings Enter the Programming Mode * - Admin C ode - # Then you can do the programming (Factory default is 777777) Change the Admin Code 0 - N ew C ode - # - R epeat the N ew C ode - # (New Code: any 6 digits) Add Card User 1 - R ead C ard - # (Cards can be added in continuously) Add PIN User 1- U s er I D - # - P IN- # (ID number:1-2000) Delete User 2 - R ead C ard - # (for Card User) 2 - U s er I D-# (for PIN User) * Exit from the Programming Mode How to r eleas e the d oor Open door by card Open door by User PIN Open door by user card + PIN (Read Card) (Users PIN) # (Read Card) (Users PIN) # E nter a nd E xit P rogram m ode P rogramming S tep K eys troke C ombination Enter Program Mode * (Admin Code) # (Factory default is 777777) Exit Program Mode * For safety, the Admin must change the Admin code. Modify Admin C ode P rogramming S tep K eys troke C ombination LED * Enter Program Mode (Admin Code) # Red shines 0 (New Admin Code) # Update Admin Code (Repeat New Admin Code) # Orange bright (Admin Code is any 6 digits) * Exit Program Mode Red bright The length of the admin code is 6 digits, the admin should keep it in mind. Add U s ers b y K eypad ( ID N umber: 1-2000) P rogramming S tep Enter Program Mode Add Card User K eys troke C ombination * (Admin Code) # LED Red shines Add Card: by Card 1 (Read Card) # OR Add Card: by ID 1 (Input ID number) # number (Read Card) # OR Add proximity cards 8 (ID number) # (8/10 sequentially numbered digits card number) # (The number of cards)# Orange bright Add PIN users 1 (ID Number) # (4-8 digits PIN) Orange bright Exit Program Mode * Red bright Note: 1. When swiping cards to add users, the user ID will be added in automatically, and ID number will be from small to big, ranged from 1 2000. 5 2.When adding card users, an attached PIN 1234 will be added in automatically. This pin cannot used to open door. If you want to open door by card + PIN, you should first change the old PIN 1234, method referring to Change PIN. 3. Before add the proximity cards sequentially numbered, the ID number should be sequential and empty. Delete U s ers b y K eypad P rogramming S tep K eys troke C ombination * Enter Program Mode (Admin Code) # Delete Card User-Common Delete Card - By Card OR Delete Card By ID number 2 (Read Card) # 2 (Input ID number) # Delete All User 2 0000 # Exit Program Mode * LED Red shines Orange bright Orange bright Red bright P uls e M ode a nd T oggle M ode S etting P rogramming S tep K eys troke C ombination LED * Enter Program Mode (Admin Code) # Pulse Mode 3 (1-99) # Toggle Mode 3 0 # Red shines Orange bright * Exit Program Mode Red bright Note: 1. Factory default is P uls e M ode and the access time is 5 seconds. When set the access time to "0", the device will be in Toggle Mode. 2. P uls e M ode: The door will be closed automatically after opening the door for a while. 3. To g g le M o d e : Under this mode, after opening the door, the door won't be closed automatically until next valid user input. That is to say, whether open or close the door, you must swipe valid card or input valid PIN. 6 A c c es s M ode S etting P rogramming S tep K eys troke C ombination LED Enter Program Mode Open door by card * (Admin Code) # 4 0 # OR Open door by card + PIN 4 1 # OR Open door by card or PIN 4 2 # (Factory default) Red shines Orange bright Exit Program Mode * Red bright A larm O utput T ime S etting P rogramming S tep K eys troke C ombination LED * Enter Program Mode (Admin Code) # Set alarm time 6(1-3) # Red shines Orange bright * Exit Program Mode Note: 1. Factory default is 1 minute. Red bright 2. Alarm output time includes: the alarm time of anti-vandal, safe mode and closing reminder. 3. Swipe valid card or Input valid PIN can remove the alarm. S et S afe M ode P rogramming S tep K eys troke C ombination LED Enter Program Mode Normal Mode OR Lockout Mode * (Admin Code) # 7 0 # (Factory default) 7 1 # Red shines Orange bright OR Alarm output Mode 7 2 # Exit Program Mode * Red bright N o te: L o c k o u t M o de: If swipe card/input PIN with invalid users for 10 times in 1 minute, the device will be lockout for 10 minutes. When the device repowered, the lockout will be canceled. A larm O utput Mode: If swipe card/input PIN with invalid users for 10 times in 1 minute, the buzzer built-in will be activated. 7 Us ers S etting C hange P IN P rogramming S tep K eys troke C ombination * Change PIN which (Read Card) (old PIN) # (New PIN) # attached to card users (Repeat New PIN) # * Change independent PIN (ID number) # (old PIN) # (New PIN) # (Repeat New PIN) # Note: The PIN can be changed to any one 4-8 digits, but cannot be `1234', and the PIN attached to the card is only used for card + PIN access mode. How to r eleas e the d oor Open door by card Open door by User PIN Open door by user card + PIN (Read Card) (Users PIN) # (Read Card) (Users PIN) # 8