Owner's Manual for MTTS models including: 4METER Lightmeter, 4METER, Lightmeter
Support | LifeKit by MTTS
Lightmeter / 4meter | LifeKit by MTTS
File Info : application/pdf, 2 Pages, 1.56MB
DocumentDocumentmeter by 4METER An instrument for determination of the actual level of sources required for an effective medical therapy. Key Functions 1. Blue light irradiance measurement: - verify irradiance of photo therapy devices during preventive maintenance and normal use 2. O2 measurement: - verify purity of O2 sources (tank, generator, wall) during preventive maintenance - verify mechanical blender and other blender during preventive maintenance - leak search inside device and along external tubes during repair and equipment inspection 3. Pressure measurement: - verify pressure at Y connector during use 4. Flow measurement: - verify flow output of CPAP, Hi-flow and ventilators during preventive maintenance 5. High pressure measurement: - verify hospital gas sources and check them for fluctuations 6. Temperature and humidity measurement: - verify the temperature uniformity of the radiant warmers - check temperature and humidity inside the incubators Light Irradiance Sensor - spectral response chosen to match wavelength used for jaundice treatment - two sided measurement for convenient measurement of double sided phototherapy devices such as the MTTS Firefly Displays/Indicators - touch screen liquid-crystal display (LCD) - alarms: low battery, system failure, out of measurement - results `freeze' - bandwidth estimator - absolute and relative irradiance measurement - multi-point mode Light Sensor Spectral Response 100 75 % 50 25 390 400 410 420 430 440 440 450 460 470 480 490 500 510 520 530 Wavelength Dimensions and Weight Ordering Information and Servicing Height Width Depth Weight 148 mm 73 mm 17 mm 200 g Performance Specifications Application LIGHT SENSOR Spectral response Measurement range Resolution Cosine characteristics Accuracy OXYGEN SENSOR FLOW SENSOR MANOMETER HIGH PRESSURE SEN. TEMP/HUMIDITY SEN. - LED and blue fluorescent phototherapy light sources; using the lightmeter for halogen phototherapy results in a minor but not considerable error - Various gas sources used for respiratory therapy 400-520nm single side 0.1 150.0 µW/cm²/nm double side 0.1 300.0 µW/cm²/nm 0.1 µW/cm²/nm ±2% @ 30 degree angle ±7% @ 60 degree angle ±25% @ 80 degree angle +/- 3% of reading FiO2 21-100% flow 0-120 lpm, bi-directional pressure pressure 0-100 cm H2O ±100 psi temperature 5-60oC humidity 0-100% RH Battery Specification ORDERING INFO Lightmeter Oxygen meter Flow meter Manometer High pressure meter Temperature/Humidity meter Rechargeable batteries and charger Storage case ITEM ORDER NO LM-800 LM-800-020 LM-800-030 LM-800-040 LM-800-050 LM-800-060 LM-800-070 Main Unit LM-800-080 Calibration Parts Required Every 2 years after delivery date; return to MTTS for calibration No customer serviceable parts; return to MTTS for service MEDICAL TECHNOLOGY TRANSFER AND SERVICES Co., LTD ISO 13485: 2016 Certified Company For more information or to place an order please contact us at: info@mtts-asia.com https://mtts-asia.com Type Lifetime 2xAAA 1.5V Alkaline, Non-rechargeable Up to 120h operating time Environmental Specification +84 24 37 666 521 No 26, Lane 41 An Duong Vuong Street Phu Thuong Ward, Tay Ho District Hanoi, Vietnam Operation Temperature Storage Temperature Operation Atmospheric Pressure Storage Atmospheric Pressure Operation Humidity Storage Humidity Sealing Drop/Shock Standards 10°C to 40°C 0°C to 50°C 70 106 kPA 70 106 kPA 30 90% RH non condensing 5 90% RH non condensing IP-54 1m onto hard surface, meets or exceeds IEC 60068-2-32 (only with the protective case) Distributor: ISO 13485:2016 IEC 61010-1:2010 IEC 61326-1:2012 LM-MKT-01-Rev-4.01EN