CamConnect Lite-User Manual-English-2023-0621
CamConnect Lite User Manual - English
Version: 1.0.3

Table of Contents
Chapter 1 System Requirements .......................................................... 2 1.1 Operating System Requirements .................................................... 2 1.2 System Hardware Requirements..................................................... 2
Chapter 2 System Connection and Application................................... 3 2.1 System Connection............................................................................. 3 2.2 Scenario................................................................................................. 3
Chapter 3 Support Devices ................................................................... 4 3.1 Shure ...................................................................................................... 4 3.2 Sennheiser ............................................................................................ 4 3.3 Nureva ................................................................................................... 4 3.4 Yamaha .................................................................................................. 4
Chapter 4 Operation Interface Description .......................................... 5 4.1 Main Screen.......................................................................................... 5 4.2 PTZ Control........................................................................................... 7
Chapter 5 Troubleshooting ................................................................... 8 Copyright Information................................................................................ 9
1

Chapter 1 System Requirements

1.1 Operating System Requirements
 Windows 10  Windows 11

1.2 System Hardware Requirements

Item

Requirements

CPU

CPU: Intel i5 / i7 above

Memory

Memory: 4GB RAM

Free Disk Space

1GB Free Disk Space

Ethernet

Min Screen Resolution: 1920x1080

2

Chapter 2 System Connection and Application

2.1 System Connection
POE + Router

Microphone System

Network cable

Network cable

USB cable
PC (with CamConnect installed)
2.2 Scenario

Camera

3

Chapter 3 Support Devices
3.1 Shure
 Shure MXA310 Table Array Microphone  Shure MXA910 Ceiling Array Microphone  Shure MXA920 Ceiling Array Microphone
3.2 Sennheiser
 Sennheiser TeamConnect Ceiling 2 (TCC2) Ceiling Microphone <Note> When using TCC2 with CamConnect, please set and configure the channels on the Sennheiser Control Cockpit software first. CamConnect is divided into 8 equal parts according to Senheisser's horizontal angle of view. They correspond to CamConnect Array Azimuth 1 to 8.
If the forbidden area is enabled on the Sennheiser Control Cockpit software, the corresponding position of CamConnect will also be affected. Example: If the forbidden area is set to 0° to 60°, the audio signal from 0° to 45° of CamConnect Array Azimuth 1 and 45° to 60° of Array Azimuth 2 will be ignored.
3.3 Nureva
 HDL300 Audio Conferencing System
3.4 Yamaha
 Yamaha RM-CG Ceiling Array Microphone
4

Chapter 4 Operation Interface Description

4.1 Main Screen 1

5 2

3

4

No

Item

1

Microphone Device

Function Descriptions
1.1 Support Device: The following brands and models are supported  Shure: MXA910_ MXA920_ MXA310  Sennhiser: TCC2  Nureva: HDL300  Yamaha: RM-CG
1.2 Device IP: IP location of the microphone device
1.3 Port:
 Shure: 2202  Sennheiser: 45  Nureva: 8931 1.4 Connect: On/Off 1.5 Advanced

5

2 Preset setting

 Audio Trigger Level > dB: Triggered only if audio source exceeds the
preset dB <Remark>For Sennhiser/ Nureva microphones only  Time To Trigger Preset: Capture sound delay setting.
When the second point sound triggers, the call preset will be delayed
based on the set second.  Back To Home Time: Back To Home Time setting.
When there is no audio source input on site, reaching the set second
will trigger back to Home.  Back To Home Position: Home Position setting
After the microphone device is connected, the camera can be controlled to turn to the corresponding position according to the microphone detection position.
There will be a green light at the front of the detection position. · Tally Light: Receive microphone signal or not (Green for Receive) · Array No.: For Shure microphones · Azimuth Angle: For Sennheiser/ Nureva/ Yamaha microphones Angle can be adjusted manually; Click [Apply] when completed
The connected USB cameras will be displayed 3.1 When disconnected, click [Connect] to connect the camera and perform
PTZ control.

3 Searching

3.2 When connected, click [Disconnect] to stop the connection.

4 PTZ Control 5 About

Click to enable PTZ control Refer to 4.2 PTZ Control for function description Displaying software version information For technical support, please scan the QRcode on the page for assistance

6

4.2 PTZ Control 8
1

2

3

6

4

5

No

Item

1 Preview window

2 L/R Direction

3 Mirror / Flip

4 Pan/Tilt/Home

5 Preset setting
6 AF/MF 7 Zoom 8 Exit

7

Function Descriptions

Display the screen currently captured by the camera

L/R Direction / Normal

Set image mirroring/ flip

Adjust the Pan/Tilt position of the camera screen

Click [Home] key

Click the number keys directly to call the preset

· Save preset: Click [Set] first and then a number key

· Clear preset: Click

first and then a number key

Switch to Auto Focus/Manual Focus. Focus can be adjusted in Manual. Zoom In/ Zoom Out ratio Exit the PTZ Control page

7

Chapter 5 Troubleshooting
This chapter describes problems you may encounter while using Lumens CamConnect. If you have questions, please refer to related chapters and follow all the suggested solutions. If the problem still occurred, please contact your distributor or the service center.

NO

Problems

Solutions

1. Check the power supply of camera or PoE power supply is

stable. 1. Unable to search camera devices
2. Make sure the PC is connected to the camera with the USB cable

3. Replace the cables and make sure they are not faulty

No response from the microphone Make sure the microphone device is connected (Link) 2.
detection position

1.Make sure the Azimuth Angle settings in the CamConnect

When using with a Sennhesier

software include that angle position

3. microphone, no response at the 2.Make sure if the angle is set as the forbidden area on Sennhesier

specific angle

Control Cockpit software. Refer to 3.2 Sennhesier Microphone

System for details.

8

Copyright Information
Copyrights © Lumens Digital Optics Inc. All rights reserved. Lumens is a trademark that is currently being registered by Lumens Digital Optics Inc. Copying, reproducing or transmitting this file is not allowed if a license is not provided by Lumens Digital Optics Inc. unless copying this file is for the purpose of backup after purchasing this product. In order to keep improving the product, the information in this file is subject to change without prior notice. To fully explain or describe how this product should be used, this manual may refer to names of other products or companies without any intention of infringement. Disclaimer of warranties: Lumens Digital Optics Inc. is neither responsible for any possible technological, editorial errors or omissions, nor responsible for any incidental or related damages arising from providing this file, using, or operating this product.