User Guide for SALUS models including: TRV10RFM, Wireless Thermostatic TRV Head, TRV10RFM Wireless Thermostatic TRV Head, TRV Head, TRV10RFM, TRV10RAM, TRV28RFM
communication protocol. It can replace classic, manual thermostatic head in a very quick and easy way. For proper operation of the TRV head it is necessary to synchronize it correctly with wireless thermostat using the CO10RF coordinator or UGE600 Internet gateway (all devices are sold separately). TRV
Note: One thermostat can control up to 6 TRV heads within one room. Quick Guide ... TRV head is compatible with most of the thermostatic valves available on.
File Info : application/pdf, 2 Pages, 340.39KB
DocumentDocumentVI 2020 [ENG] Wireless, thermostatic TRV head Manual for models: TRV10RFM, TRV10RAM i TRV28RFM Quick Guide DISTRIBUTOR OF SALUS CONTROLS: QL CONTROLS Sp. z o.o., Sp. k. Rolna 4, 43-262 Kobielice, Poland Importer: SALUS Controls Plc Units 8-10 Northfield Business Park Forge Way, Parkgate, Rotherham S60 1SD, United Kingdom www.salus-controls.eu SALUS Controls is a member of the Computime Group Maintaining a policy of continuous product development SALUS Controls plc reserve the right to change specification, design and materials of products listed in this brochure without prior notice. Introduction The TRV thermostatic head is controlled through wireless ZigBee communication protocol. It can replace classic, manual thermostatic head in a very quick and easy way. For proper operation of the TRV head it is necessary to synchronize it correctly with wireless thermostat using the CO10RF coordinator or UGE600 Internet gateway (all devices are sold separately). TRV head paired with the iT600RF series digital thermostats (e.g. VS10RF / VS20RF / HTRS-RF (30) / HTRP-RF (50) / TS600) provides comfort within the whole room, not just in the radiator area. Product Compliance This product complies with the essential requirements and other relevant provisions of Directives 2014/53/EU, 2014/30/EU, 2011/65/EU. The full text of the EU Declaration of Conformity is available at the following internet address: www.saluslegal.com. Safety Information Use in accordance to national and EU regulations. Use the device as intended, keeping it in dry condition. Product for indoor use only. Installation must be carried out by a qualified person in accordance to national and EU regulations. Box Content TRV10RFM TRV28RFM TRV10RAM TRV10RFM adapter TRV28RFM Each box additionally contains: metal washer TRV10RAM Allen Wrench key Manual instruction 2 x AA batteries General informations The TRV head is a modulating device. This means that the valve can be gradually closed or opened, depending on the current room temperature measured by thermostat and the setpoint temperature. + + OR Note: One thermostat can control up to 6 TRV heads within one room. To achieve the best possible results in cooperation between the thermostat and the heating source, it is recommended to use the RX10RF receiver. RX10RF turns on the heat source depending on the demand signal sent by thermostat. More informations about RX10RF receiver is included in its user manual. Checking compatibility with the heating system TRV head is compatible with most of the thermostatic valves available on the market, however, before installation, please check whether the valve is suitable for use with the TRV head. 1 dismantle the old radiator head radiator valve Note: If all valve dimensions are consistent with those given below, then the TRV head will be compatible. If there are dimension differences, contact us or the installer to find replacement for the valve. 20 2 30 3 10 mm 20 10 mm Measure the thread diameter. Thread for the TRV10RFM must have a diameter of 30 mm, and for the TRV28RFM - 28 mm. Measure the height of the valve's pin when it is in the open position. For TRV10RFM valve's pin height should be 13-15 mm, while for TRV28RFM 10-11 mm. TRV28RFM head installation For MMA or Herz M28x1,5 thermostatic valves make sure you have a metal washer as shown in the picture. NOTE: For the Comap valve with M28 thread you do not need to mount a metal washer. TRV10RFM head installation For a standard thermostatic valve with M30x1,5 thread (e.g. Oventrop, Honeywell, TA, Heimeier) TRV10RFM head installation looks like as shown in the picture. TRV head installation on the Danfoss RA valve When mounting the TRV10RFM head on the Danfoss RA valve (see picture), please use the RA adapter included with the head. However, to install the TRV10RAM head it is necessary to use the Allen Wrench key. Put the RA adapter on the Danfoss RA valve. TRV10RFM HEAD MOUNTING Tight RA adapter and screw TRV10RFM head on it. Place TRV head on the valve. TRV10RAM HEAD MOUNTING Assembly to the valve and tighten only 2 out of 4 screws. TRV head setup 1 2 Remove the battery cover located on Insert the batteries according to the the side of the device. markings and close the battery cover. 3 4 The LED will start blinking green / red informing about the software version. When the LED diode lights up continuously with a red color, screw the TRV on the valve. 5 6 Press any button to start the adaptation process of TRV head with thermostatic valve. The process takes up to 5 minutes. When the LED goes out and TRV head does not make any sounds, adaptation process is finished. Equipment is ready for pairing with thermostat. User interface 1 LED diode (indicates device status) 2 Opening the head / indication of the device status 3 Closing the head / indication vof the device status 4 Pairing button Buttons function Note: Buttons lock itself automatically after 5 minutes from the last one keystroke. To do this... ...pair with thermostat ...lock/unlock the buttons ...manually open the valve ...manually close the valve ...enter the automatic mode ...remove the head from the ZigBee network ...restore factory default settings Press the... ...pairing button for 10 seconds. ...pairing and close buttons together for 5 seconds. ...opening button for 5 seconds. ...closing button for 5 seconds. ...shortly pairing button ...pairing button for 10 seconds ...Open , pairing , and close buttons together for 5 seconds Choose the type of coordinator for ZigBee network Choose one type of ZigBee network coordinator and prepare it for work with iT600 series devices: · Online - system is connected to the Internet via an Internet gateway UGE600 or · Offline - with an option of connecting system to the Internet using a gateway UGE600 or · Offline - by using CO10RF coordinator - no possible to connect system to the Internet Thermostat pairing with the TRV head in Online mode WARNING! You can connect up to 6 TRV heads to one regulator. 1 Install the TRV head on the valve according to the instructions on the previous page. 2 10 sec. Press and hold the pairing button for 10 seconds, the diode on the TRV head should start flashing in red. 3 SALUS Smart Home 4 5 6 9 Name this equipment TRV in the living room 11 3 12 0 TRVs on this thermostat 7 Scan for equipment 8 Connect equipment 10 Finish LED diode on TRV head flashes in orange. Now TRV head need to be paired with thermostat. NOTE: TRV head and thermostat must be in the same heating zone! 13 Select TRV(s) for living room Name this equipment 14 Save 15 3 1 TRVs on this thermostat Thermostat pairing with the TRV head in Offline mode WARNING! You can connect up to 6 TRV heads to one regulator. 1 Install the TRV head on the valve according to the instructions on the previous page. 10 sec. Press and hold the pairing button for 10 seconds, the diode on the TRV head should start flashing in red. Note: The following example shows the pairing process with the VS10/20..RF thermostat. For HTRS-RF(30) and HTRP-RF(50) thermostats, the pairing process shall be done in the same way. 2 3 4 Choose the device type - TRV head 5 Open the ZigBee network 5 sec. 5 sec. OR WARNING! Do not use the CO10RF coordinator together with UGE600. 6 Device is paired with the coordinator, diode on TRV head will start blinking in orange. 7 Diode on the TRV head lights up once green, then stops flashing. 8 TRV head has been added. 9 Thermostat will go to the main screen. 10 Close the ZigBee network 5 sec. 5 sec. OR LED diode indications When... TRV Status LED diode... Valve ...power supplied TRV head indicates the software version ...alternately flashes red / green indicating the software version. A more detailed description is in,,TRV head setup" section on the previous page. ...TRV head adapts to the valve ... flashes in green, then red and it switches off when the adaptation process has been done. When the LED will continue to flash red it means that adaptation process failed. ...TRV head has been added to the network. ... flashes in orange (has been added to the network). TRV head should be paired now closed with thermostat. ..TRV head is added to the network, but it is not paired with thermostat ...TRV head is in normal operating mode ...TRV head is paired with thermostat. ...TRV head is removed from the network. ...identification of the TRV head is turned on Auto mode TRV head is open in manual mode TRV head is closed in manual mode Auto mode Auto mode TRV head is open in manual mode TRV head is closed in manual mode The Window Open function is active Auto mode ...flashes in orange ...flashes twice in green when pressed the opening or closing button. ...flashes once in green after a short press of the opening or closing button. ...flashes once in green after a short press of the opening or closing button. ...flashes once in red after short press of the opening or closing button. ....flashes twice in green after short press of the opening or closing button. ...flashes twice in red after short press of the opening or closing button. ...flashes in green and red 2 times every 10 seconds. ...does not light up. ...flashes once in orange (TRV head is removed from the coordinator's memory) and then flashes in red. ...flashes in green for a maximum of 10 minutes. closed 100% open closed open in range from 1% up to 100% closed 100% open closed closed ... wireless communication with the TRV head is lost Auto mode TRV head is open in manual mode TRV head is closed in manual mode ...when battery power is too low ...an error occurred during TRV head assembly ...flashing alternately in green and red after a short press of the opening or closing button. ...flashes twice in green after a short press of 100% the opening or closing button. open ...flashes twice in red after a short press of the opening or closing button.. closed ...flashes three times in red every 10 seconds (or less often if the batteries in the TRV head are very weak). 25% open ... flashes alternately in red and green. Additional functions: Frost protection mode When valve is manually closed, the TRV head automatically activates frost protection mode. Setpoint temperature of the frost protection mode is set on the thermostat. This function is activated when the room temperature drops below the frost protection setpoint teperature set on the thermostat. TRV head automatically maintains setpoint temperature if there is communication between TRV head and thermostat. Open window function TRV head checks the speed of temperature drop in the room. If the temperature drop is fast, it is assumed that in the room has been opened window. The function is active when the TRV head communicates with thermostat, is in automatic mode and the batteries are not discharged. Protection against scale deposits Do not leave the valve open for a long time because it can cause scale deposits on it. TRV head has a protection function against scale deposits. It starts to opening automatically once every 14 days if no valve movement is detected. Protection will also work no matter if TRV head is in auto mode or manual mode Manual mode To open or close the TRV head in manual mode, follow the procedure described below. If the steps described below do not bring any results it means that probably the TRV head buttons are locked and they should be unlocked first. To open the valve manually, press and hold the opening button. The green 5 sec. LED diode flashes once and the TRV head will start to open the valve. To close the valve manually, press and hold the closing button. The red LED 5 sec. diode flashes once and the TRV head will start closing the valve. Note: To exit the manual mode and go back to auto mode - press once the pairing button (antenna). The red LED diode will flash once, indicating return to auto mode. Technical Information Model Type LED signaling TRV10RFM / TRV28RFM / TRV10RAM Wireless, thermostatic TRV head M30 x 1.5 / M28 x 1.5 Tri-color LED (red/green/orange) Adaptation with a valve Automatic Power supply 2 x AA batteries Control method Modulation Communication Wireless, ZigBee 2.4 GHz Operating temperature Storage temperature 0 to 45°C -20 to 60°C Ambient humidity 5 to 95% RH IP protection level IP30 Dimensions [mm] H=88.6, Ø=51 Warranty SALUS Controls warrants that this product will be free from any defect in materials or workmanship, and shall perform in accordance with its specification, for a period of two years from the date of installation. SALUS Controls sole liability for breach of this warranty will be (at its option) to repair or replace the defective product. Customer Name: .................................................................................. Customer Address: .............................................................................. .......................................................................................................................... ............................................................................... Post Code:......................... Tel No: ............................................................................................................. Email: .............................................................................................................. Engineers Company: ........................................................................................ Tel No: ............................................................................................................. Email: .............................................................................................................. Instalation Date: .............................................................................................. Engineers Name: ................................................................................. Engineers Signature: ........................................................................................Adobe InDesign 16.1 (Windows) 3-Heights(TM) PDF Optimization Shell 5.9.1.5 (http://www -tools.com)