Instruction Manual for MBJ models including: HDF-05, HDF-07, HDF-10, HDF Series Horizontal Ringlights, HDF Series, HDF Series Ringlights, Horizontal Ringlights, Ringlights

Horizontal Ringlights

Datenblatt

Horizontale Ringlichter - MBJ Imaging

Mechanical Integration Safety Notes

Horizontal Ringlights Operating Manual Technical Data Model Sizes in Series The lightis available in the following sizes 1) HDF-05 HDF-07 HDF-10 1) Size definition: HDF-10 refers to an inner light diameter of 100 mm.


File Info : application/pdf, 2 Pages, 435.97KB

PDF preview unavailable. Download the PDF instead.

Manual-HDF-Horizontal-Ringlight-Series-WEB
Mechanical Integration
The lights are equipped with 4 combined mounting positions of threaded or through holes. It can be used to fix the lighting to the specified position. To secure a long lifetime additional heat transfer measurements at the holding positions is highly recommended.
Example: Model HDF-07
More 2D and 3D drawings can be found online: www.mbj-imaging.com

Safety Notes
Before working with this unit, read the warning and application instructions carefully and completely before operating the device.

Operating Manual Technical Data
Horizontal Ringlights

Specification Operating temperature
Certifications Degree of protection
Humidity

Horizontal Ringlight Series 10°C to 30°C CE, RoHS IP54 30 % to 70 %

1. The device is designed for indoor use only.
2. Light ­ Due to the risk of flash burn of the eyes it is not recommended to look directly into the light source. The lighting must be switched off before installation and/or maintenance. The device must not be used when a failure may cause a personal injury.
3. Heat - In case of insufficient heat dissipation or when running the light in flash mode with a too high duty cycle, the surface temperature may exceed 60 °C. Keep off flammable materials at any time.
4. Electricity - The housing is electrically isolated from the ground of the power supply. Exceeding the permissible input voltage Uin or ULED(+) can lead to the destruction of the device or to a significant shortening of the lifetime of the LEDs in the device.
5. Usage ­ Please prevent mechanical stress to the light surface during operation. This will lead to a inhomogenious light emission.
6. Cleaning - The light emission surface has to be cleaned with a standard glass cleaner and a soft cleaning cloth. Do not use other material for cleaning as it will damage the device.

03203.04 Manual MBJ Horizontal Ringlight HDF-Series, August 2023

MBJ Imaging GmbH

Jochim-Klindt-Straße 7

+49 4102 778 90 31

22926 Ahrensburg, Germany

sales@mbj-imaging.com

www.mbj-imaging.com

Model Sizes in Series

The lightis available in the following sizes 1)

HDF-05

HDF-07

HDF-10

1) Size definition: HDF-10 refers to an inner light diameter of 100 mm.

Possible LED Colors

LED

Abbr.1)

Peak Wavelength2)

White

-WT

5000 K, CRI80

Red

-RD

near 625 nm

Infrared

-IR

near 850 nm

Green

-GN

near 525 nm

Blue

-BE

near 465 nm

Yellow

-YE

near 580 nm

1) Color option will be added to the model name after the size information. HDF-07-RD refers to a horizontal ringlight with 625 nm red light.
2) This is an approximated value. The exact value also depends on LED temperature and LED current.

Electrical Connection
The lighting is equipped with an 4 pin M8x1 connector.

Pin

Color 1)

Standard (-s)

Direct (-x) 2)

1

brown

24 VDC

LED (+)

2

white

Dim

LED (+)

3

blue

Trigger

LED (-)

4

black

Ground

LED (-)

1) wire color of MBJ lighting cable 2) connection to 24VDC without external LED controller may destroy the unit

Additional Information:
Pin3 (Trigger) is an `active high' input signal with 5...24 V=ON and 0...1 V=OFF, it is a high resistance current sink with 0.2 mA for 5 V and 5 mA for 24 V
Pin2 (DIM) is used as brightness control and operation mode switch, it is a high resistance current sink with 0.2 mA for 5 V and 1 mA for 24 V.
For the connection it is recommended to use the MBJ lighting cable with a maximum length of 10 m.

Integrated Controller (-s)
Supported operation modes with the integrated LED controller

Pin 2 (Dim)

Operation mode

24 V

steady light 1)

1...10 V

steady light with brightness control 2)

24 V

triggered light

GND

triggered flash light with max. 20 ms and

up-to 100 % more light intensity 3)

1) Pin 3 (Trigger) needs permanent 24 V to activate steady light mode 2) PWM with 3.8kHz clock is used, recommended minimal camera exposure is 5ms 3) Latency between trigger and LED light ON is about max. 30µs, the maximum recom-
mended clock speed is 1 kHz, the maximum recommended duty cycle is 25 % and the minimum recommended flash time is 100 µs

Application Samples for (-s) controller

Steady light
24 VDC

1 Power

2 Dim

MBJ

LED light 3 Trigger

4 GND

Steady light with brightness control

24 VDC 24 VDC

3k9

1 Power

2 Dim

MBJ

10k

LED light 3 Trigger

4 GND

Specification

HDF-05

HDF-07

HDF-10

Optical parameter

Luminous area (ID) Light emission

50 mm

75 mm Horizontal, side fired ringlight with slightly diffuse light emission

100 mm

Recommended use

used mainly for darkfield applications

Recommended light working distance

1 mm - 30 mm

Electrical parameter

Available interfaces

-s with integrated LED Controller and 4 operation modes; -x with direct LED access (external LED control is required)

Uin for -s Version

24 VDC +/- 5 %

ULed(+) range for -x version2) Typical Power (-s version)

WT / BE / YE: 17 ... 20 VDC; GN: 20 ... 23 VDC; RD: 12 ... 15 VDC; IR: 9 ... 12 VDC

Steady light operation

6 W / 3 W / 2 W

During ON time at flashed light operation

16 W

Recommended LED current (-x version)

Steady light (100 % duty cycle)

300 mA (450 mA for IR)

Flash light (50 % duty cycle, < 500 ms pulse)

600 mA (450 mA for IR)

Flash light (25 % duty cycle, < 50 ms pulse)

900 mA (450 mA for IR)

Flash light (10 % duty cycle, < 5 ms pulse)

1200 mA (900 mA for IR)

General parameter

Dimension (H x W x D)

130 mm x 141 mm x 12 mm

130 mm x 141 mm x 12 mm

130 mm x 141 mm x 12 mm

Weight

360 g

330 g

300 g

Material

Black anodized aluminum housing with PMMA light guide

Connector

M8x1 socket, 4 pin, male (for pinning details refer to chart "Electrical Connection")

Accessories

For cable and external LED controller: please check www.mbj-imaging.com

1) Values are approximate with +/- 7 % tolerance 2) Lower voltage value refers to steady light, higher voltage value refers to flash light, please see max. allowed current in the rows below. 3) Power for Blue / Yellow is comparable to White, Power for Green is approx. 1,2 times higher. 4) Triggered flash light with max. 20 ms and up to 100 % more light intensity, calculated for White.

Triggered light with NPN sinking output (inverted strobe signal, open collector)
24 VDC

2k2

from Camera/ PLC etc

11 mA

1 Power

2 Dim

MBJ

LED light 3 Trigger

4 GND

Flashed light with PNP sourcing

24 VDC from Camera/ PLC etc

24 VDC

15 mA

2k2

1 Power

2 Dim

MBJ

LED light 3 Trigger

4 GND



References

Adobe PDF Library 10.0.1 Adobe InDesign CS6 (Windows)