di-soric LA-D 48-25-1175-1360 I-D Light Grid
Product Model: 207313
Product Overview
- Diagonal beam evaluation
- Integrated evaluation electronics
- Switching output
- Fault alarm output
- Compact design
- Aluminum housing
- Easy to install
Diagrams and Wiring
Light Grid Components and Dimensions: Diagram shows the light grid setup with 1) Transmitter, 2) Receiver, and 3) Monitoring height (H). It also indicates 4) Profile length (L) and 6) Profile cross-section (24x12 mm). The overall dimensions are labeled A: 80 mm, B: 600 mm, X: 20 mm, Y: 160 mm.
Wiring Diagram: The Sender (Transmitter) connects via Brown (BN) for positive (+) and Blue (BU). The Receiver (Empfänger) has connections for Brown (BN) for positive (+), Black (BK) for signal (S), Blue (BU) for pnp output, and Yellow (YE) for Alarm. Wire color key: BK: black, BN: brown, BU: blue, YE: yellow.
Beam Path: A diagram illustrates the light beams passing between the transmitter and receiver, defining the operational range and monitoring height.
Technical Data (Typical)
General Specifications
Parameter | Value |
---|---|
Service voltage | +20°C, 24 V DC (20.4 ... 28.8 V DC) |
Power consumption | 8 W |
Assembly | Threaded bolt (3) |
Profile cross section | 12 x 24 mm |
Dimension | A: 80 mm, B: 600 mm, X: 20 mm, Y: 160 mm |
Profile length | 1.360 mm |
Housing material | Aluminum (silver, Anodized) |
Protection class | III, operation on protective low voltage |
EMC directives | EN 61000-6-3:2001 / EN 61000-6-1:2001 |
Evaluation | Diagonal |
Evaluation electronics | Integrated |
Output function | Dark switching |
Switching output | pnp, 200 mA, NO, short-circuit-proof |
Light source | LED |
Color | Infrared |
Wavelength | 880 nm |
Performance and Environmental Specifications
Parameter | Value |
---|---|
Beam evaluation | Via integrated evaluation electronics |
Beam separation | 25 mm |
Number of beams | 48 |
Monitoring height | 1.175 mm |
Range | 700 ... 4.000 mm (factory setting) |
Display | LED (Service voltage / output stage, error (alarm)) |
Cycle time per light beam | 1 ms |
Total cycle time | Number of beams x 1 ms + 4 ms |
Basic processing time | 4 ms |
Ambient temperature during operation | -10 ... +45 °C |
Protection type | IP 54 (IP 65 optional) |
Connection | Cable, 4.0 m (with ferrule) |
Additional Information
For more information and accessories, please visit: