Instruction Manual for D D Technologies models including: KL1100 CodeLocks Keypad KitLock Locker Lock, KL1100, CodeLocks Keypad KitLock Locker Lock, Keypad KitLock Locker Lock, KitLock Locker Lock, Locker Lock
D&D Technologies CodeLocks KL1100 Keypad KitLock Locker Lock
File Info : application/pdf, 9 Pages, 284.49KB
DocumentDocumentCodelocks Support KL1100 Keypad - Programming and Operating Instructions Table of contents Overview Penalty Time Batteries Access Methods Code Clients The KL1100 Keypad has four Code Client levels Master Code Client (8 digits) Sub-Master Code Client (8 digits) Technician Code Client (6 digits) User Code Clients (4 digits) Functions Operating Instructions Change the Master Code (Private & Public Function) Set or Change the User Code (Private Function) Delete a User Code (Private Function) Set or Change the Sub-Master Code (Private & Public Function) Delete the Sub-Master Code (Private & Public Function) Auto-Unlock (Public Function) Auto-Unlock At a Set Time (Public Function) Disable Auto-Unlock At a Set Time (Public Function) https://codelocks.zohodesk.eu/portal/en/kb/articles/kl1100-keypad Set or Change Date & Time Restrict Opening Time Change Locked Indication (Public Function) Troubleshooting Factory Reset Keypad Method (Private & Public Function) Manual Method Firmware Check Overview Penalty Time Inputting an incorrect Code 3 times will incur a 10 second time delay before any further use is possible. Batteries The KL1100 Keypad uses 4 x AA batteries. Always use high quality batteries and dispose of old batteries according to local authority recommendations. When battery power is low, the Red LED will flash 3 times before any unlocking. Batteries should be changed as soon as this happens. Access Methods The lock supports a maximum of: Master Code Clients (1), Technician Code Clients (1) and User Code Clients (20 in Private Function). Code Clients The KL1100 Keypad has four Code Client levels Master Code Client (8 digits) https://codelocks.zohodesk.eu/portal/en/kb/articles/kl1100-keypad Opens the Lock (deletes current User Code Client in Public Function) All programming including Technician and User Code Client registration The default Master Code Client is 11335577 Sub-Master Code Client (8 digits) Opens the Lock (deletes current User Code Client in Public Function) Limited programming including Technician and User Code Client registration Technician Code Client (6 digits) Opens the Lock (retains current User Code Client in Public Function) User Code Clients (4 digits) Open the Lock Lock the Lock (in Public Function) Change the User Code Client (in Public Function) The default Master Code Client is 2244 Important! Once a Master Code Client is registered, it should be kept in a safe location. The Master Code is required for all programming operations. Functions Before programming, select the most appropriate function for the application: A) or B) - See special Master Code set up commands. A) Private Function Important Note: This is the default function and is already pre-programmed in new locks. This is the most common function and is used where the same code will be repeatedly used. B) Public Function The user enters their own personal four-digit code to lock the lock. Entering the same code will open the lock and clear the code, ready for the next user. This function is used for short term, multi occupancy applications, e.g. a locker in a leisure centre. Operating Instructions All programs must begin by pressing the # button followed by the Master, Sub-Master or User Codes as required. https://codelocks.zohodesk.eu/portal/en/kb/articles/kl1100-keypad Recommended: The Master Code can be used to change all settings and should be kept safe and not shared. Change the Master Code (Private & Public Function) #Master Code 01 New Master Code New Master Code Example: #11335577 01 12345678 12345678 Result: The Master Code has been changed to 12345678. Set or Change the User Code (Private Function) #Master or Sub-Master Code 02 User Position New User Code Example: #11335577 02 01 7788 Result: The User Code in position 01 has been set to 7788. Note: Up to 20 User Codes can be created. Each User is entered at a single, known position. Delete a User Code (Private Function) #Master or Sub-Master Code 03 User Position Example: #11335577 03 01 Result: The User Code in position 01 has been deleted. Note: To delete all User Codes, enter 00 as the User Position. Set or Change the Sub-Master Code (Private & Public Function) #Master or Sub-Master Code 04 New Sub-Master Code New Sub-Master Code Example: #11335577 0 499887766 99887766 Result: The Sub-Master Code has been changed to 99887766. Delete the Sub-Master Code (Private & Public Function) https://codelocks.zohodesk.eu/portal/en/kb/articles/kl1100-keypad #Master Code 05 05 Example: #11335577 05 05 Result: The Sub-Master Code has been disabled. Auto-Unlock (Public Function) #Master Code 10 Time <01-24> hours Example: #11335577 10 06 Result: The lock will automatically unlock 6 hours after being locked Disable Auto-Unlock (Public Function) #Master Code 07 00 Example: #11335577 07 00 Result: The lock will not automatically unlock and will remain locked until User/Master/Sub-Master Code entered. Auto-Unlock At a Set Time (Public Function) #Master Code 11 HHmm Example: #11335577 11 2000 Result: The lock will automatically unlock at 20:00 Disable Auto-Unlock At a Set Time (Public Function) #Master Code 11 HHmm Example: #11335577 11 2400 Result: The lock will not automatically unlock and will remain locked until User/Master/Sub-Master Code entered. Set or Change Date & Time #Master Code or Sub-Master Code 12 YYMMDD HHmm Example: #11335577 12 200226 1128 Result: The date/time has been set for February 26th, 2020 at 11:28 https://codelocks.zohodesk.eu/portal/en/kb/articles/kl1100-keypad NOTE : DST is not supported. Restrict Opening Time #Master Code or Sub-Master Code 18 HHmm (Start) HHmm (End) Example: #11335577 12 0830 1700 Result: User Code can only be used between 08:30 and 17:30. Change Locked Indication (Public Function) #Master Code 08 Disable or Enable <00 or 01> Example: #11335577 08 00 Result: The locked indication has been disabled. Note: By default, locked indication is enabled, the red LED will flash once every 5 seconds to indicate a locked lock. Set or Change Technician Code (Private & Public Function) #Master Code Or Sub-Master Code 13 New Technician Code Confirm New Technician Code Example: #11335577 13 555777 555777 Result: The Technician Code 555777 has been added. Delete the Technician Code (Private & Public Function) #Master Code Or Sub-Master Code 13 000000 000000 Example: #11335577 13 000000 000000 Result: The Technician Code has been Deleted. Public Function (Double Entry) #Master Code 22 Example: #11335577 22 https://codelocks.zohodesk.eu/portal/en/kb/articles/kl1100-keypad Result: The lock will operate in Public Function, remaining unlocked until a User enters their own Code (twice) to lock. Public Function (Single Entry) #Master Code 24 Example: #11335577 24 Result: The lock will operate in Public Function, remaining unlocked until a User enters their own Code (once) to lock Private Function #Master Code 26 Example: The lock will operate in Private Use, remaining locked unless opened by a valid code. Any User Codes in position 02 to 20 will erased. A default User Code of 2244 will be active in position 01. Change own User Code (Private Function) #User Code New User Code New User Code Example: #2244 6611 6611 Result: Own User Code has been changed to 6611. Troubleshooting Battery Level Check #Master or Sub-Master Code 87 Example: #11335577 87 Result: Both the Red / Blue LED will flash to indicate the current battery status. The lock will then return to normal mode. Battery Level Indication <80% 50% - 80% https://codelocks.zohodesk.eu/portal/en/kb/articles/kl1100-keypad 20% - 50% <20% Battery Failure After a Code is entered, the red LED will flash 3 times to indicate low power. The KitLock will operate for a further 100 openings. The batteries should be replaced as soon as possible. Battery Failure Override The KL1100 KeyPad has been designed so that a mobile power bank can be used to open the lock to allow access to the batteries so they can be replaced should they fail. 1. Plug the power bank into the micro USB port at the bottom of the lock, it will power up. 2. Enter the Master Code. 3. Whilst the lock is in an unlocked state, open the cabinet and replace the batteries found in the latch unit. Factory Reset Master Code Unknown: If the Master Code has been forgotten, the manual method must be used. Keypad Method (Private & Public Function) #Master Code 9999 Example: #11335577 9999 Result: All User Codes will have been deleted, the Sub-Master and Technician Codes disabled and all settings reverted to factory default. The Master Code will be 11335577 and a single User Code of 2244 will be available. The lock will be in Private Function. Manual Method 1. Open battery compartment 2. Remove a single battery 3. Press & hold pinhole reset button with a wire pin 4. Replace battery, whilst continuing to press the reset button 5. Release the reset button 6. Within three seconds, press the reset button three times https://codelocks.zohodesk.eu/portal/en/kb/articles/kl1100-keypad Result: All User Codes will have been deleted, the Sub-Master and Technician Codes disabled and all settings reverted to factory default. The Master Code will be 11335577 and a single User Code of 2244 will be available. The lock will be in Private Function. Firmware Check To check the firmware version installed on the lock. #Master Code 88 Example: #11335577 88 Result: The LED will flash to indicate firmware version (e.g. Red LED flash once and Blue LED flash twice, firmware version is 12). User can wait 30 seconds to exit or can press `0' button to exit and return to normal mode. https://codelocks.zohodesk.eu/portal/en/kb/articles/kl1100-keypad