Dell PowerEdge R630 Statement of Volatility

This document outlines the volatile and non-volatile components within the Dell PowerEdge R630 server. Volatile components lose their data immediately upon power removal, while non-volatile components retain data even after power is removed. User-definable configuration options not soldered to the motherboard are excluded. Information on configuration options for components like microprocessors, remote access controllers, and storage controllers is available separately. The following non-volatile (NV) components are present in the PowerEdge R630 server.

Component Details

Item Non-Volatile or Volatile Quantity Reference Designator Size Type (e.g. Flash PROM, EEPROM) Can user programs or operating system write data to it during normal operation? Purpose? (e.g. boot code) How is data input to this memory? How is this memory write protected? How is the memory cleared?
Planer
PCH Internal CMOS RAM Non-Volatile 1 U_PCH 256 Bytes Battery-backed CMOS RAM No Real-time clock and BIOS configuration settings BIOS N/A - BIOS only control 1) Set NVRAM_CLR jumper to clear BIOS configuration settings at boot and reboot system; 2) AC power off system, remove coin cell battery for 30 seconds, replace battery and power back on; 3) restore default configuration in F2 system setup menu.
BIOS Password Non-Volatile 1 U_PCH 16 bytes Battery-backed CMOS RAM Yes Password to change BIOS settings Keyboard N/A Place shunt on J_PSWD_NVRAM jumper pins 2 and 4.
BIOS SPI Flash Non-Volatile 1 U_SPI_BIOS 8 MB SPI Flash No Boot code, system configuration information, UEFI environment, Flash descriptor, ME SPI interface via iDRAC Software write protected Not possible with any utilities or applications and system is not functional if corrupted/removed.
IDRAC SPI Flash Non-Volatile 1 U_IDRAC_SPI 4 MB SPI Flash No iDRAC Uboot (bootloader), server management persistent store (i.e. IDRAC MAC Address, iDRAC boot variables), lifecycle log cache, virtual planar FRU and EPPID, rac log, system event log, JobStore, iDRAC Secure boot code, SPI interface via iDRAC Embedded iDRAC subsystem firmware actively controls sub area based write protection as needed. Not completely user clearable; however, user data, lifecycle log and archive, SEL, fw image repository can be cleared via Delete Configuration and Retire System, accessible in Lifecycle Controller interface
BMC EMMC Non-Volatile 1 U_EMMC 4 GB eMMC NAND Flash No Operational iDRAC FW, Lifecycle Controller (LC) USC partition, LC service diags, LC OS drivers, USC firmware NAND Flash interface via iDRAC Embedded FW write protected Not completely user clearable; however, user data, lifecycle log and archive, SEL, fw image repository can be cleared via Delete Configuration and Retire System, accessible in Lifecycle Controller interface
CPU Vcore Regulators Non-Volatile 2 U8003, U8043 512 Bytes ROM No Operational parameters NA Not user clearable Not user clearable
Vmem Regulators Non-Volatile 2 U8011, U8051 512 Bytes ROM No Operational parameters NA Not user clearable Not user clearable
System CPLD RAM Volatile 1 U_CPLD 1 KB RAM No Not utilized Not utilized Not accessible Not accessible
System Memory Volatile Up to 12 per CPU CPU<2:1>_CH<3:0>_D<2:0> Up to 64GB per DIMM DRAM Yes System OS RAM System OS OS Control Reboot or power down system
Internal USB Key Non-Volatile Up to 1 N/A Varies (not factory installed) Flash Yes General purpose USB key drive USB interface via PCH. Accessed via system OS No write protect Can be cleared in system OS
Trusted Platform Module (TPM) Non-Volatile 1 U_TPM 128 Bytes EEPROM Yes Storage of encryption keys Using TPM Enabled operating systems SW write protected F2 Setup option
CPU Volatile 1 or 2 CPU1 / CPU2 Various Cache + registers Yes Processor cache + registers Various Various Power off
IDRAC DDR Volatile 1 U_IDRAC_MEM 256MByte DRAM No iDRAC local memory IDRAC Firmware NA Power off
IDRAC Volatile 1 U_IDRAC 64 kbyte + registers Cache + registers No Processor cache + registers IDRAC Firmware NA Power off
8x2.5" Backplane
SEP internal flash Non-Volatile 1 U3 Flash:32KB+4KB EEPROM: 1KB Integrated Flash+EEPROM No Firmware + FRU 12C interface via iDRAC Program write protect bit Not user clearable
10x2.5" (or 6x2.5" + 4x PCIe SSD) EXP/Backplane
NVSRAM memory Non-Volatile 1 U1 1 Mb Flash No FW config data Common Flash memory interface (CFI) Hardware strapping Not user clearable
Flash memory Non-Volatile 1 U2 32 Mb Flash No Firmware Common Flash memory interface (CFI) Hardware strapping Not user clearable
Expander FRU image Non-Volatile 1 U5 512 Bytes I2C EEPROM No FRU I2C interface via iDRAC Hardware strapping Not user clearable
BP FRU image Non-Volatile 1 U15 256 Bytes I2C EEPROM No FRU I2C interface via iDRAC Hardware strapping Not user clearable
24x2.5" EXP/Backplane
NVSRAM memory Non-Volatile 1 U3 1 Mb Flash No FW config data Common Flash memory interface (CFI) Hardware strapping Not user clearable
Flash memory Non-Volatile 1 U2 32 Mb Flash No Firmware Common Flash memory interface (CFI) Hardware strapping Not user clearable
Expander FRU image Non-Volatile 1 U7 512 Bytes I2C EEPROM No FRU I2C interface via iDRAC Hardware strapping Not user clearable
BP FRU image Non-Volatile 1 U3 256 Bytes I2C EEPROM No FRU I2C interface via iDRAC Hardware strapping Not user clearable
H730, H830 PERCS
NVSRAM Non-volatile 1 U1033 128KB NVSRAM No Configuration data ROC writes configuration data to NVSRAM Not WP. Not visible to Host Processor Cannot be cleared with existing tools available to the customer
FRU Non-volatile 1 U1019 256B FRU No Card manufacturing information Programmed at ICT during production. Not WP? Cannot be cleared with existing tools available to the customer
1-Wire EEPROM Non-volatile 1 U1004 128B 1-Wire EEPROM No Holds default controller properties/settings ROC writes data to this memory Not WP. Not visible to Host Processor Cannot be cleared with existing tools available to the customer
SPD Non-volatile 1 U22 256B SPD No Memory configuration data Pre-programmed before assembly Not WP. Not visible to Host Processor Cannot be cleared with existing tools available to the customer
SBR Non-volatile 1 U1020 8KB SBR No Bootloader Pre-programmed before assembly Not WP. Not visible to Host Processor Cannot be cleared with existing tools available to the customer
Flash Non-volatile 1 U1031 16MB Flash No Card firmware Pre-programmed before assembly. Can be updated using Dell/LSI tools Not WP. Not visible to Host Processor Cannot be cleared with existing tools available to the customer
ONFI Backup Flash Non-volatile 1 U1059 4GB ONFI Backup Flash No Holds cache data during power loss FPGA backs up DDR data to this device in case of a power failure Not WP. Not visible to Host Processor Flash can be cleared by powering up the card and allowing the controller to flush the contents to VDs. If the VDs are no longer available, cache can be cleared by going into controller bios and selecting Discard Preserved Cache.
SDRAM Volatile 5 U1043-U1047 512MB/1GB SDRAM No Cache for HDD I/O ROC writes to this memory - using it as cache for data IO to HDDs Not WP. Not visible to Host Processor Cache can be cleared by powering off the card
H330, H330M PERC
NVSRAM Non-volatile 1 U1033 128KB NVSRAM No Configuration data ROC writes configuration data to NVSRAM Not WP. Not visible to Host Processor Cannot be cleared with existing tools available to the customer
FRU Non-volatile 1 U1019 256B FRU No Card manufacturing information Programmed at ICT during production. Not WP? Cannot be cleared with existing tools available to the customer
1-Wire EEPROM Non-volatile 1 U1004 128B 1-Wire EEPROM No Holds default controller properties/settings ROC writes data to this memory Not WP. Not visible to Host Processor Cannot be cleared with existing tools available to the customer
SBR Non-volatile 1 U1020 8KB SBR No Bootloader Pre-programmed before assembly Not WP. Not visible to Host Processor Cannot be cleared with existing tools available to the customer
Flash Non-volatile 1 U3 16MB Flash No Card firmware Pre-programmed before assembly. Can be updated using Dell/LSI tools Not WP. Not visible to Host Processor Cannot be cleared with existing tools available to the customer
PCIe SSD Extension Card
Switch Configuration EEPROM Non-Volatile 1 U2 256B SPI Flash EEPROM No (requires specialized SW) Configuration for PLX PCIe switch, setting registers The EEPROM image is pre-loaded at factory before assembly. Once assembled on the card, data can be entered via PLX Device Editor or PLX EEP DOS based tool. Device can be write protected via hardware pin. Alternatively, device contents can be write protected via WPEN bit in status register. System is not functional as intended if corrupted/removed.
IDSDM
SPI Flash Non-Volatile 1 U2 8Mb SPI Flash No Exclusively used by the controller SPI interface via iDRAC Hardware strapping Not user clearable
MCU Non-Volatile 1 U6 512KB Embedded Flash FW can be updated via iDRAC which runs on Linux Firmware USB3.0 interface via PCH N/A Not user clearable
x8 Control Panel
rSPI Flash Non-Volatile 1 U3 32Mb SPI Flash No restored SPI SPI interface via iDRAC Hardware strapping Not user clearable
x10/x24 Control Panel
rSPI Flash Non-Volatile 1 U6 32Mb SPI Flash No restored SPI SPI interface via iDRAC Hardware strapping Not user clearable
iDRAC Quick Sync
MCU MSP430 Non-Volatile 1 U_MSP430 128KB Flash No iDRAC Quick Sync Communicate Protocol I2C interface via iDRAC Hardware strapping Not user clearable - It also auto-clears when power is applied.
Power Supplies
PSU FW Non-Volatile 1 per PSU Varies by PSU Part Number Up to 2MB which varies by part number Embedded microcontroller flash No Power Supply operation, power management data and fault behaviors Different vendors have different utilities and tools to load the data to memory. It can also be loaded by Dell Update Package from LC or OS (Windows and Linux) Protected by the embedded microcontroller. Special keys are used by special vendor provided utilities to unlock the ROM with various CRC checks during load. Not user clearable

Notes

NOTE: For any information that you may need, direct your questions to your Dell Marketing contact.

© 2016 Dell Inc. Trademarks used in this text: Dell™, the DELL logo, and PowerEdge™ are trademarks of Dell Inc.

PDF preview unavailable. Download the PDF instead.

all-products/esuprt ser stor net/esuprt poweredge/poweredge-r630 reference guide3 en-us Dell Inc. Adobe PDF Library 11.0; modified using iTextSharp 5.1.3 (c) 1T3XT BVBA

Related Documents

Preview Dell U3225QE UltraSharp Monitor Statement of Volatility
Details on the volatile and non-volatile components of the Dell UltraSharp 32 4K Thunderbolt Hub Monitor (U3225QE), including a list of non-volatile components and their data retention properties.
Preview Dell U4025QW Monitor Statement of Volatility
This document details the volatile and non-volatile components of the Dell U4025QW Monitor, outlining their data retention characteristics and remedial actions for data erasure.
Preview Dell UltraSharp 27 4K Thunderbolt Hub Monitor U2725QE Statement of Volatility
This document details the volatile and non-volatile components of the Dell UltraSharp 27 4K Thunderbolt Hub Monitor U2725QE, outlining their data retention characteristics and remedial actions.
Preview Dell OptiPlex 3080 Small Form Factor Statement of Volatility
Details the volatile and non-volatile components within the Dell OptiPlex 3080 Small Form Factor computer, explaining their data retention characteristics and system state behavior.
Preview Dell PowerEdge R860 Installation and Service Manual
Comprehensive guide for installing, configuring, and servicing the Dell PowerEdge R860 server. Covers system overview, technical specifications, component replacement, diagnostics, and troubleshooting.
Preview Dell PowerEdge R360 Technical Guide
Explore the technical specifications, features, and system overview of the Dell PowerEdge R360, an entry-level rack server designed for evolving business computing needs. This guide covers system architecture, processors, memory, storage, networking, power supply, and management capabilities.