Instruction Manual for NOTIFIER models including: Swift Wireless AV Base, Swift, Swift AV Base, Wireless AV Base, AV Base
Notifier SWIFT Wireless AV Bases (Wall and Ceiling) - Fire Alarm Resources - Free fire alarm PDF manuals, documents, installation instructions, and technical specifications
File Info : application/pdf, 3 Pages, 780.74KB
DocumentDocumentSWIFT Wireless AV Base General The NOTIFIER SWIFT® AV bases WAV-CRL, WAV-CWL, WAV-RL, and WAV-WL are intended for use with compatible System Sensor L-Series AV notification appliances to meet a comprehensive range of notification requirements. The AV Base provides power for the audio and visual signals and supports wireless communication with the Fire Alarm Control Panel (FACP). The L-Series AV notification appliance is mounted directly to the wireless AV base allowing flexibility in color, placement and signal output. Power is supplied through two sets of 4 batteries one set provides power for wireless communication, and the other set provides power for the notification appliance's audio and/or visual signal. Battery life of the wireless portion is UL listed for at least 2 years. Battery life for the AV set of batteries depends upon the activation time and output level of the audio or visual signal. The AV base boosts output voltage to support 24 VDC options on connected devices. The SWIFT synchronization module (W-SYNC) can be used to provide audio and visual synchronization between SWIFT notification appliances and System Sensor wired notification appliances. The wireless synchronization module operates from 24 V power with supplemental battery support and communicates through the mesh network to the gateway and FACP. Synchronization is only available with notification appliances that use the System Sensor synchronization protocol. Synchronization of the SWIFT notification appliances within a single mesh network is inherent in the wireless system and a wireless synchronization module is not needed. The W-SYNC also provides wireless control and monitoring of a Notification Appliance Circuit (NAC) expander or power supply. SWIFT SYSTEM OVERVIEW The SWIFT Smart Wireless Integrated Fire Technology wireless system offers intelligent (addressable) devices which provide secure, reliable communication to the Fire Alarm Control Panel (FACP) across a Class A mesh network. Wireless devices create an opportunity for applications where it is costly (concrete walls/ceilings, buried wires), obtrusive (surface mount conduit), or possibly dangerous (asbestos) to use traditional wired devices. It allows fast installation for time-critical situations and provides the flexibility to add wireless onto wired systems for retrofit installations. Both wired and wireless devices can be present on the same FACP for an integrated solution. The mesh network within the SWIFT system creates a child-parent relationship between the devices so that each device has two parents providing a second path for communications on every device. If one device can no longer operate for any reason, the rest of the devices can still communicate with each other, directly or through one or more intermediate devices. Once an initial mesh network is formed, mesh restructuring automatically occurs to find the strongest paths possible within the network. Features · Converts compatible System Sensor L-Series AV appliances to addressable wireless AV appliances · Wireless installation · Class A mesh network · Addressable code wheels · Commercial applications · Listed to UL 464, UL 1638, and UL 1971 · Frequency hopping · Bi-Directional Communications Specifications PHYSICAL/OPERATING SPECIFICATIONS · Dimensions (Ceiling): Diameter 7.4" (19 cm); Depth 1.6" (4 cm) · Weight: 20.0 oz (567 g) installed with 8 batteries ELECTRICAL SPECIFICATIONS · Maximum Transmit RF Power: 17 dBm · Radio Frequency Range: 902-928 MHz · Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing · Operating Temperature Range: 32°F to 120°F (0°C to 49°C) · Battery Type: 8 Panasonic® CR123A or 8 Duracell® DL123A · Battery Life: RF batteries: 2 year minimum. AV batteries: See battery life table. · Battery Replacement: Replace during annual maintenance or when TROUBLE BATTERY LOW displays. Ordering Information · W-BATCART: Wireless battery cartridge 10-pack · SMB500-WH: White surface mount back box · WAV-CRL: Wireless AV base, ceiling, red · WAV-CWL: Wireless AV base, ceiling, white · WAV-RL*: Wireless AV base, wall, red · WAV-WL*: Wireless AV base, wall, white · W-SYNC: Wireless sync module *NOTE: WAV-RL & WAV-WL are compatible with wall-mount L-Series devices manufactured after 26 April 2019 (date code 9045 and later). WAV-CRL and WAV-CWL are compatible with all ceiling-mount L-Series devices. DN-61067:C · 8/17/2020 -- Page 1 of 3 firealarmresources.com COMPATIBLE EQUIPMENT Note: ULC-listed models have all required languages. Model (UL Model (ULC listed) listed) Description CHRL CHSCRL CHRLA* CHSCRLA* CHSCRLA-E Chime Red Wall Chime/Strobe Red Ceiling Chime/Strobe Red Ceiling, English CHSCWL CHSCRLA-F CHSCWLA* CHSCWLA-E Chime/Strobe Red Ceiling, French Chime Strobe White Ceiling Chime/Strobe White Ceiling, English CHSRL CHSCWLA-F CHSRLA* CHSRLA-E Chime/Strobe White Ceiling, French Chime Strobe Red Wall Chime/Strobe Red Wall, English CHSWL CHSRLA-F CHSWLA CHSWLA-E Chime/Strobe Red Wall, French Chime Strobe White Wall Chime/Strobe White Wall, English CHWL HCRL-LF CHSWLA-F CHWLA HCRLA-LF* Chime/Strobe White Wall, French Chime White Wall 520Hz Sounder Red Ceiling HRL HRL-LF HCWL-LF HRLA HRLA-LF* HCWLA-LF* Horn Red Wall 520Hz Sounder Red Wall 520Hz Sounder White Ceiling HWL HWL-LF HWLA HWLA-LF* P2RLA* Horn White Wall 520Hz Sounder White Wall Horn/Strobe 2-wire Red Wall P2RL P2RL-LF P2RLA-E P2RLA-F P2RLA-LF* Horn/Strobe 2-wire Red Wall, English Horn/Strobe 2-wire Red Wall, French 520Hz Sounder/Strobe Red Wall P2RL-P P2RL-SP P2RLA-P -- P2WLA Horn Strobe 2-wire Red Wall, Plain Horn Strobe 2-wire Red Wall, Fuego Horn Strobe 2-wire White Wall P2WL P2WL-LF P2WLA-E P2WLA-F P2WLA-LF* Horn/Strobe 2-wire White Wall, English Horn/Strobe 2-wire White Wall, French 520Hz Sounder/Strobe White Wall P2WL-P P2WL-SP P2WLA-P -- PC2RLA* Horn Strobe 2-wire White Wall, Plain Horn Strobe 2-wire White Wall, Fuego Horn Strobe 2-wire Red Ceiling PC2RL PC2RLA-E PC2RLA-F PC2WLA* Horn/Strobe 2-wire Red Ceiling, English Horn/Strobe 2-wire Red Ceiling, French Horn Strobe 2-wire White Ceiling PC2WL PC2WLA-E PC2WLA-F SCRLA* Horn/Strobe 2-wire White Ceiling, English Horn/Strobe 2-wire White Ceiling, French Strobe Red Ceiling SCRL SCRLA-E* SCRLA-F Strobe Red Ceiling, English Strobe Red Ceiling, French SCWL SCWL-CLRALERT SRL SRL-P SRL-SP SWL SWL-ALERT SWL-CLRALERT SWL-P SCWLA* SCWLA-E SCWLA-F -- SRLA* SRLA-E SRLA-F SRLA-P -- SWLA* SWLA-E SWLA-F -- -- SWLA-P *Bilingual Canadian model Strobe White Ceiling Strobe White Ceiling, English Strobe White Ceiling, French Strobe White Ceiling Clear Lens Alert Strobe Red Wall Strobe Red Wall, English Strobe Red Wall, French Strobe Red Wall, Plain Strobe Red Wall, Fuego Strobe White Wall Strobe White Wall, English Strobe White Wall, French Strobe White Wall, Amber Lens Strobe White Wall, Clear Lens Strobe White Wall, Plain Page 2 of 3 -- DN-61067:C · 8/17/2020 firealarmresources.com AV BATTERY LIFE: TEMPORAL 3, AMBIENT CONDITIONS AV Battery Life at Temporal 3, Ambient Conditions Model Model Type Minutes at 15 cd Minutes at 30 cd Minutes at 75 cd Battery Life (Minutes), per Candela Setting Minutes at Minutes at Minutes at Minutes at 95 cd 110 cd 115 cd 135 cd Wall 127h 23m -- -- -- -- -- -- Chime-only Ceiling -- -- -- -- -- -- -- Wall 31h 51m -- -- -- -- -- -- Horn-only Ceiling -- -- -- -- -- -- -- Wall Strobe-only Ceiling 20h 44m 21h 45m 14h 09m 14h 09m 8h 20m 8h 02m 7h 22m 6h 39m 6h 02m -- -- 5h 39m 5h 11m -- ChimeStrobe Wall Ceiling 18h 12m 18h 35m 12h 55m 12h 44m 7h 58m 7h 41m 6h 31m 6h 28m 5h 18m -- -- 5h 24m 4h 26m -- Wall Horn-Strobe Ceiling 16h 31m 12h 34m 12h 03m 9h 54m 7h 22m 6h 14m 6h 17m 5h 24m 5h 30m -- -- 4h 46m 4h 33m -- Low-Freq. Wall 8h 15m -- -- -- -- -- -- Sounder- Only Ceiling 8h 15m -- -- -- -- -- -- Low-Freq. Sounder- Wall Strobe -- 9h 6m 7h 45m 5h 39m 4h 56m 4h 54m -- Battery life will decrease using continuous tone or other coded patterns and under non-ambient environmental conditions. Minutes at 150 cd -- -- -- -- -- 4h 43m -- 4h 29m -- 4h 07m -- -- 4h 12m Minutes at 177 cd -- -- -- -- -- 3h 57m -- 3h 45m -- 3h 31m -- -- -- Minutes at 185 cd -- -- -- -- 4h 01m -- 3h 37m -- 3h 38m -- -- -- -- Standards The WAV-CRL, WAV-CWL, WAV-RL, and WAV-WL SWIFT Wireless AV Base is designed to comply with the following standards: · UL 864 9th Edition and 10th edition · NFPA 72 Agency Listings and Approvals These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult the factory for the latest listing status. · UL/ULC Listed: S4011 · FM Approved: 3062564 · CSFM: 7300-1653:0513 NOTIFIER 12 Clintonville Road Northford, CT 06472 203.484.7161 www.notifier.com This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. NOTIFIER®, System Sensor®, and SWIFT® are registered trademarks of Honeywell International Inc. Duracell® is a registered trademark of Duracell U.S. Operations Inc. Panasonic® is a registered trademark of Panasonic Corporation. ©2020 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. Country of Origin: Mexico firealarmresources.com