Instruction Manual for YHDC models including: TST024L, TST024L Split Core Current Transmitter, Split Core Current Transmitter, Current Transmitter, Transmitter
File Info : application/pdf, 3 Pages, 848.96KB
DocumentDocumentTST024L Split core current transmitter Split coresuspension indtallationoutput with cable.Detect AC current. High insulation between primary and secondary circuits. Installation diagram Product features ·Light weight ·Low power consumption ·Good linearity ·No insertion loss ·Fast response time ·Good anti-interference ability 1.Loosen the card buckle 2.Open up Product application ·Railway ·Metallurgical ·Welding machine ·Robot ·Motor ·Inverter power supply ·Variable frequency governor 3.In the lead 4.Fasten card buckle ·Uninterrupted power supply and communication power supply www.poweruc.pl E l e c t r i c a l p a r a m e t e r s : The following parameters are typical values and actual values will be subject to product testing Remarks Rated input Input measurement range Rated output Accuracy Linearity Supply voltage(±5%) Current consumption Load impedance Zero offset voltage Response time weight Operating temperature Storage temperature Band width Delectric strength 100A 200A 300A 120A 240A 360A 0-20mA/4-20mA/0-5V/1-5V/0-10V 0.5% Standard input Default is 1.2 times the input rating Output one of five 0-10V output +24V power supply 0.5% +12V / +24V Supply voltage range ±5% 35mA Current type output Voltage type output 250 Typification) 10K Current type output Voltage type output ±0.08mA ±15mV 200mS 196g Reference will be subject to the measured TA=25 Reference will be subject to the measured Reference will be subject to the measured -10+70 -25+70 50~400Hz 2.5KV 50Hz 1min Instruction for use 1.Connect the wires correctly according to the marked connection mode 2.With hole measurement, response time and following the speed for the best 3.Faulty wiring can lead to product damage and output uncertainty Safe operation: *Please read this specification carefully before use. *When you need to move the product, please be sure to disconnect the power and all the connected cables. *If found shell, devices attached to the fixed parts, wire, or have any damaged, please immediately deal with hidden dangers. *If there is any doubt about the safe operation of the equipment, the equipment and the corresponding accessories should be closed immediately, and the fastest time for troubleshooting. Proclamations As our products are constantly being improved and updated, we reserve the right to modify the content of this specification at any time without prior notice. www.poweruc.pl Dimensions(in mm±0.5 24 Opening angle 180° Cable 41.4 34.2 Cable specification 0.2mmThree core shielding wire Three core colorRedaBlackaGreen Cable length50cm 75 gain zero potentiometer 53 Wiring diagram gain zero Cable definition Red + V Black G N D Green o u t + out GND Acquisition module power The auxiliary power supply with ripple small (10mV) is selected Switch on auxiliary power Auxiliary power is connected to the transmitter Transmitter detects the primary current www.poweruc.pl