EP DROP 1-2: Electronic Panel for Controlling 1 or 2 Pumps on First Rain Collection Tanks
The EP DROP 1-2 is an electronic panel specifically designed for first rain collection tank installations. It ensures the emptying of the first rain collection tank. Once the meteorological event is over, the rain sensor connected to the panel will start the emptying pump after the programmed time has elapsed.
This panel is compact, economical, and very easy to install and program, making it an ideal replacement for older, already installed panels.
Key Features
- Targeted Application: Specifically designed for "first rain" systems.
- Intuitive: Maximum simplicity for configuration and use.
- Complete: Supplied with a rain sensor as standard.
- Maximum Control: Equipped with the most comprehensive system protections.
Main Characteristics
- Front panel indicator light for alarm status signaling.
- Operation buttons: AUTOMATIC – 0 (standby) – MANUAL (fixed or pulsed).
- Motor alternation for EP DROP 2.
- Protection against dry running with level/float sensors.
- Up to 4 control inputs: floats.
- Thermal probe inputs (Klixon) with automatic reset (can be disabled).
- Selectable overcurrent protection delay.
- Automatic reset for minimum current alarm (can be disabled).
- Network return activation delay (can be disabled).
- Manual button operation (fixed or temporary).
- Provision for starting capacitors for single-phase versions (not included).
- Timer for system activation delay after the end of the meteorological event (programmable).
- Rain sensor.
Versions
- Single-phase: 100-240Vca 50/60Hz
- Three-phase: 310-450Vca 50/60Hz
Controls
- Electronic maximum current control with assisted calibration.
- Electronic minimum current control (dry running) with assisted calibration.
- Phase sequence control for missing or incorrect phases in the power supply (can be disabled).
Alarms
- Signaled alarms: voltage status, levels, motor overload, minimum motor current, motor Klixon.
- General alarm output contacts.
Protections
- Auxiliary and motor protection fuses.
- General door interlocked disconnector (if provided).
- ABS housing, IP55 rated.
Integrated Functions on EP DROP 2
- Motor alternation.
- Immediate motor exchange in case of anomaly.
Technical Specifications
EP DROP 1
Model | Voltage | Power (kW) | Power (CV) | Current Range (A) | Max Current (A) | Fig. | Housing Material | Weight [kg] |
---|---|---|---|---|---|---|---|---|
EP DROP 1-Mono | 1~230 V | 2.2 | 3 | 0-18 A | 18 A | 1 | Plastic | 1.5 |
EP DROP 1-Tri/7.5 | 3~400 V | 7.5 | 10 | 0-16 A | 16 A | 1 | Plastic | 2.3 |
EP DROP 1-Tri/11 | 3~400 V | 11 | 15 | 16-25 A | 25 A | 1 | Plastic | 2.5 |
EP DROP 1-Tri/15 | 3~400 V | 15 | 20 | 16-32 A | 32 A | 1 | Plastic | 3 |
EP DROP 2
Model | Voltage | Power (kW) | Power (CV) | Current Range (A) | Max Current (A) | Fig. | Housing Material | Weight [kg] |
---|---|---|---|---|---|---|---|---|
EP DROP 2-Mono | 1~230 V | 2.2 | 3 | 0-18 A | 18 A | 1 | Plastic | 1.5 |
EP DROP 2-Tri/7.5 | 3~400 V | 7.5 | 10 | 0-16 A | 16 A | 1 | Plastic | 2.5 |
EP DROP 2-Tri/11 | 3~400 V | 11 | 15 | 16-25 A | 25 A | 2 | Plastic | 3 |
EP DROP 2-Tri/15 | 3~400 V | 15 | 20 | 16-32 A | 32 A | 2 | Plastic | 3.5 |
Dimensions [mm]
FIG. 1
Height: 390 mm, Width: 230 mm, Depth: 185 mm
FIG. 2
Height: 310 mm, Width: 230 mm, Depth: 240 mm
Wiring Diagram
A diagram shows the terminal connections for OUT, ALARM (NC, C, NO), T1, C, CO, BUZZ, G/P1, G/P2, GA, 12Vcc 100mA, and PS12-EGO terminals, along with connections for a rain sensor.
Options (Available on Request)
- Audible alarm (90 dB, 12Vcc).
- Flashing alarm indicator light (12V AC/DC).
- Daily programmer with jumpers.
- Digital weekly programmer.
- Work pause timer.
- External 24Vca command for utility activation/stop.
- External 230Vca command for utility activation/stop.
Accessories
- PROXPS RS485 Modbus module.
- PRO-SL level sensor module.
- PRO-SL H20 oil sump infiltration module.
- PRO-6D0 dry contact BMS module.
- PRO-DBT buffer battery module.
- Bluetooth module for PROXPS App.
- Pressure switches: SQUARE D 4.6 IP20 F1/4 1.4-2.8 M NC, SQUARE D 7 IP20 F1/4 4.3-5.4 M NC, TELEMECANIQUE 6 IP54 F1/4 1.8-4.8 M NC, TELEMECANIQUE 6 IP54 F1/4 1.8-4.8 NO/NC, TELEMECANIQUE 6 IP54 F1/4 1.8-4.8 T NC, SQUARE D 10.5 IP20 F1/4 4.3-5.4 M NC, TELEMECANIQUE 12 IP54 F1/4 3.6-10.3 M NC.
- K3SL Kit 3 cable-free level sensors.
- Float switches: 5m PVC with counterweight, 10m PVC with counterweight, 20m PVC with counterweight.
- Taurus float switches (various lengths and cable types).
- EBARA RNC-1002 float switch (10 m).
Special Configurations (Available on Request)
- Single-door IP65 fiberglass enclosure.
- Double-door full IP65 fiberglass enclosure.
- Double-door full IP65 metal enclosure.
- Double-door transparent IP65 fiberglass enclosure.
- Double-door transparent IP65 metal enclosure.
- 100 mm floor mounting base.
- Hollow column with floor mounting.