Installation Guide for BRUNDLE models including: 1822013, TILT-LOC, Glass Spigot Side Fix Tilt, TILT-LOC Glass Spigot Side Fix Tilt, 1822013 TILT-LOC Glass Spigot Side Fix Tilt

TILT-LOC - INSTALLATION GUIDE - F H Brundle

1 apr 2022 — Whilst every effort has been made to ensure the accuracy of the information supplied. F.H. Brundle cannot be held responsible for any errors or omissions.

PDF preview unavailable. Download the PDF instead.

TiltLocInstruction
TILT-LOC - INSTALLATION GUIDE

BRUNDLE

PRODUCT CODE
1822013
STEP 1
Drill holes and install screw, exposed thread length 23mm, slide on the spigot.

STEP 2
Tighten the nut using the adaptor included. Requires a 16mm spanner.

STEP 3
Install gaskets and screws.

STEP 4
Install the glass, adjust the glass angle to align to the adjacent panel. (the adjustment range is ±2°)

STEP 5
Tighten the screws using a 5mm Allen key.

STEP 6
Please pay attention when tightening the third screw, as this has the effect on increasing the clamping strength.

GASKET SPECIFICATIONS REQUIRED TO INSTALL DIFFERENT GLASS

Glass
10 - 12mm 12 - 13.52mm 13.52 - 15mm 15 - 16.76mm 16.76 - 17.52mm

Gasket
1 U gasket + 5 x 1mm flat gaskets 1 U gasket + 4 x 1mm flat gaskets 1 U gasket + 2 x 1mm flat gaskets 1 U gasket + 1 x 1mm flat gasket 1 U gasket

Whilst every effort has been made to ensure the accuracy of the information supplied. F.H. Brundle cannot be held responsible for any errors or omissions. This product must only be employed for its original intended use. Any other use is wrong and potentially dangerous. Installation must be carried out in full compliance with current regulations. F.H. Brundle cannot be held liable for any damages resulting from wrongful, erroneous or negligent use.