THINGS TO CHECK BEFORE INSTALLATION

CLIFF Spec Diagram

HUUM CLIFF 9.0STU Pkg | Steam Sauna Bath

HUUM CLIFF 10.5STU Pkg | Steam Sauna Bath

PDF preview unavailable. Download the PDF instead.

CLIFF Spec Diagram
THINGS TO CHECK BEFORE INSTALLATION
· Does the output (kW) match the volume (m³) of the sauna room? See Table 1.
· In case there are any uninsulated brick, tile or glass walls in the sauna room, an additional volume of 1,5 m³ should be added to the sauna room for each such square meter of the wall.
· The suitable output of the heater will be determined based on Table 1.
· The producer's warranty guarantee is invalid if the heater and sauna room have been dimensioned incorrectly!
· Minimal safe distances between the sauna room's ceiling and walls in view of installing the electric heater are listed in Table 1.

Min. 1200 B

3,5 *

H A

4
6 X 40
875 A

* CLIFF Mini 3,5 is attached to the wall with a special bracket See CLIFF Mini 3,5 heater data in the table below.
4

Table 1

Output Room Weight A B H

kW

m3

kg mm mm mm

Width/ Depth
mm

Fuse A

Power cable N × mm2

CLIFF Mini 3,5

3,5 3,5-6 15 60 390 975 270/160 10

3 × 2,5

CLIFF 6

6

5­10 16 60 390 975 270/270 10 5 × 2,5

CLIFF 9

9

9­15 16 120 510 975 270/270 16 5 × 2,5

CLIFF 10,5 10,5 10-17 17 120 510 975 270/270 16 5 × 2,5

INSTALLATION
Positioning the heater
· The heater must be positioned in such a way that there is a safe distance between flammable materials and the external surfaces of the heater. See Figure.
· In installing the heater, it must be prevented that people could have physical contact with the heater or that other dangerous situations could emerge during the heating process.
· CLIFF Mini holds approximately 60 kg of stones and CLIFF holds approximately 75 kg.
· The input of the power cable is located on the bottom cover of the heater.
Connecting the heater to the power supply
· Only a certified electrician is allowed to connect the heater to the power supply.
· A rubber insulated SIHF-JB cable or an equivalent cable must be used as the connection cable.
· It is recommended to connect the unit to the mains without an earth-leakage circuit breaker.
· The maximum current intensity in the cross-sectional area of the cable and circuit breaker are listed in Table 1.
5

