Test Report

Report Details

Report No.: AiTSZ-250709012RRev1

Dated: 2025-07-24

Applicant

CRISOL TECHNOLOGY CO., LTD.

Address: 9th Floor, Building 5, Futong Haizhi Science and Technology Park, Nanwan Street, Longgang District, Shenzhen City, Guangdong Province

Manufacturer

Zhejiang Zhongguang Environmental Equipment Co., Ltd

Address: 3F, Workshop 1, No.109, Qibaiyang Street, Nanmingshan Street, Liandu District, Lishui City, Zhejiang Province

Testing Laboratory

Guangdong Asia Hongke Test Technology Co., Ltd.

Address: B1/F, Building 11, Junfeng Industrial Park, Chongqing Road, Heping Community, Fuhai Street, Bao'an District, Shenzhen, Guangdong, China

Website: https://www.aitek.org.cn

Email: info@aitek.org.cn

Phone: +86. 0755-23096763

Sample Information

Sample Name: RV Water purifier

Model No.: GFRVRO01

Serial Model No.: GFRVRO01-G, GFRVRO01-H

Sample Received Date: 2025-07-09

Test Period: 2025-07-09 to 2025-07-15

Test Overview

Test Requested: Refer to the following page(s)

Test Method: Refer to the following page(s)

Test Result: Refer to following page(s)

Prepared by: Oliver (Project Handler)

Reviewed by: Lizhen (Designated Reviewer)

Component List

No. Name
1Filter element base screw
2Check valve spring
3Water bottle check valve spring
4Kettle
5Water bottle sealing ring
6Transparent sealing ring
7Filter element water sealing ring
8Turntable water-sealing O-ring
9Large sealing ring of the turntable
10PE pipe
11The upper shell of the kettle seat
12The lower cover of the kettle seat
13Upper cover of the filter element
14Lower cover of the filter element
15Filter bottle
16Filter bottle end cap
172 points directly converted to 2 points
182 points for a bend and 2 points for a straight insert
19Elbow (with socket)
202 minutes, 1 conversion, 2-3 passes
212 points 3 ways (right Angle)
22Kettle check valve
23Filter element seat
24Filter element seat turntable
25Filter element seat fixing plate
26Filter element one-way valve cover
27Filter element one-way valve stem
28A 2-point plug

Test Results

FDA Compliance Testing

Extractable Lead and FDA GRAS Chromium Content

Test Method: With reference to ASTM C738-94(2016) for Extractable Lead; US EPA 3050B:1996; US EPA 6010D:2018 for FDA GRAS Chromium Content.

Item Test Condition Unit Result Limit
1 2 3
Extractable Lead (Pb) 4% acetic acid, 22°C, 24h mg/L <0.1 <0.1 <0.1 Adult: 7
Conclusion / / Pass Pass Pass /
Chromium(Cr) GRAS/ICP-OES % 13 13 13 ≥10.5

Notes: 1. % = percent by weight; 2. N.D. = Not detected (less than method detection limit); 3. Photo appendix is included.

FDA CFR 21 181.32 - Acrylonitrile Copolymers Requirement

Ref: FDA 21 CFR 181.32

Test Item(s) Test condition Unit Result Limit
4
Acrylonitrile in Distilled Water 120°F, 24h mg/in² N.D. 0.003
Acrylonitrile in 3% Acetic Acid 120°F, 24h mg/in² N.D. 0.003
Acrylonitrile in 8% Ethanol 120°F, 24h mg/in² N.D. 0.003
Acrylonitrile in n-Heptane 120°F, 24h mg/in² N.D. 0.003
Conclusion -- -- Pass --

Note: -N.D. = Not Detected or less than Detection limit; -This product material is ABS material

FDA 21 CFR 177.2600 - Rubber articles intended for repeated use.

Ref: FDA 21 CFR 177.2600

Test Item(s) and condition Unit Result Limit
5 6 7 8 9
Total extractives in D.I. water reflux temperature for 7 hours mg/in² <0.1 <0.1 <0.1 <0.1 <0.1 20
Total extractives in D.I. water reflux temperature for succeeding 2 hours mg/in² <0.1 <0.1 <0.1 <0.1 <0.1 1
Total extractives in n-hexane reflux temperature for 7 hours mg/in² <0.1 <0.1 <0.1 <0.1 <0.1 175
Total extractives in n-hexane reflux temperature for succeeding 2 hours mg/in² <0.1 <0.1 <0.1 <0.1 <0.1 4
Conclusion / Pass Pass Pass Pass Pass /

FDA CFR 21 177.1520 - Polymer: Olefin Polymers Requirement

Ref: FDA 21 CFR 177.1520

Test Item(s) Test condition Unit Result Limit
10
Density -- g/cm³ 0.927 0.85-1.00
Maximum soluble fraction in n-hexane 50°C 2h W/W% 1.5 5.5
Maximum soluble fraction in xylene 25°C 1h W/W% 2.5 11.3
Conclusion -- -- Pass --

Note: -N.D. = Not Detected or less than Detection limit; -This product material is PE material

FDA CFR 21 177.1520 - Polymer: Olefin Polymers Requirement (Continued)

Ref: FDA 21 CFR 177.1520

Test Item(s) Test condition Unit Result Limit
11 12 13
Density -- g/cm³ 0.892 0.892 0.892 0.880-0.913
Melting point -- °C 173 173 173 160-180
Maximum soluble fraction in n-hexane Reflux 2h W/W% 1.5 1.5 1.5 6.4
Maximum soluble fraction in xylene 25°C 1h W/W% 2.5 2.5 2.5 9.8
Conclusion -- -- Pass Pass Pass --

FDA CFR 21 177.1520 - Polymer: Olefin Polymers Requirement (Continued)

Ref: FDA 21 CFR 177.1520

Test Item(s) Test condition Unit Result Limit
14 15 16
Density -- g/cm³ 0.892 0.892 0.892 0.880-0.913
Melting point -- °C 173 173 173 160-180
Maximum soluble fraction in n-hexane Reflux 2h W/W% 1.5 1.5 1.5 6.4
Maximum soluble fraction in xylene 25°C 1h W/W% 2.5 2.5 2.5 9.8
Conclusion -- -- Pass Pass Pass --

FDA CFR 21 177.1520 - Polymer: Olefin Polymers Requirement (Continued)

Ref: FDA 21 CFR 177.1520

Test Item(s) Test condition Unit Result Limit
20 21
Density -- g/cm³ 0.892 0.892 0.880-0.913
Melting point -- °C 173 173 160-180
Maximum soluble fraction in n-hexane Reflux 2h W/W% 1.5 1.5 6.4
Maximum soluble fraction in xylene 25°C 1h W/W% 2.5 2.5 9.8
Conclusion -- -- Pass Pass --

Note: -N.D. = Not Detected or less than Detection limit; -This product material is PP material

FDA CFR 21 177.2470 - Polyoxymethylene copolymer.

Ref: FDA 21 CFR 177.2470

Items Test Condition Unit MDL Limits Results
Water extractives 120°F, 24h mg/in² 0.1 0.5 0.11
8% ethanol extractives 120°F, 24h mg/in² 0.1 0.5 0.17
N-heptane extractives 70°F, 30min mg/in² 0.1 0.5 0.21
Extractives in distilled water Reflux temperature, 6h % 0.1 0.2 N.D.
Extractives in n-heptane Reflux temperature, 6h % 0.1 0.15 0.12

Note: -N.D. = Not Detected or less than Detection limit

Supersede: This test report is used to replace the test report numbered AiTSZ-250709012R. The original paper report and electronic version report of AiTSZ-250709012R are invalid accordingly.

Sample Photos

The following images show the RV Water purifier and its components:

This technical report may only be quoted in full. Any use for advertising purposes must be granted in writing. This report is the result of a single examination of the object in question and is not generally applicable evaluation of the quality of other products in regular production.