LUTRON HQRK-R25NE-240 Series Home Works QS Inline Control
Specifications:
- Product Name: In-line Dimmer
- Model Number: P/N 043613 Rev A
- LED Load Capacity: 1A, 150W
- Incandescent / Halogen Load Capacity: 1A, 250W
- Motor Load Capacity: 2A, 0.5 HP
- Fan Control Load Capacity: Single AC Ceiling Fan, 100W
- Compliance: ImDA standards DA 103083
Product Usage Instructions
In-line Dimmer
- HQRK-R25NE-240
- HQRM-R25NE-240
- HQRN-R25NE-240
- HQRQ-R25NE-240
- 220 – 240 V~ 50 / 60 Hz
* LED Load Capacity: LED current ratings must be below 1 A. If no current rating is available, wattage must be below 150 W.
In-line Switch
- HQRK-R6ANS-240
- HQRM-R6ANS-240
- HQRN-R6ANS-240
- HQRQ-R6ANS-240
- 220 – 240 V~ 50 / 60 Hz
In-line Fan Control
- HQRK-RNFSQ-240
- HQRN-RNFSQ-240
- 220 – 240 V~ 50 / 60 Hz
Single AC Ceiling Fan 100 W
Installing the in-line load control
Turn OFF power at circuit breaker or remove fuse
WARNING: SHOCK HAZARD.
May result in serious injury or death. Always isolate the mains power supply or remove fuse before servicing or installing.
Connect wires
- L = Live
= Earth
- N = Neutral
= Dimmed Live
= Switched Live
= Fan Live
Products must be installed in accordance with the latest building and IEE wiring regulations.
Install strain relief and tighten screws
Ground wires require additional length during installation.
Two sizes of strain reliefs included. A provides the best strain relief for most wire diameters. For some large wire applications, B will be needed.
Note: All outside wire diameters must be the same and must be between 5.2 – 8.5 mm.
Pairing a Pico Wireless Control to an In-Line Load Control Without a System
CAUTION: RISK OF BODILY HARM. The ceiling fan will start spinning when a Pico wireless control button is pressed after pairing. Remain clear of the ceiling fan before pressing the Pico wireless control buttons. This only applies to in-line fan controls.
- Press and hold the button on the in-line load control for six (6) seconds. The LED will begin flashing. The device will stay in pairing mode for ten (10) minutes.
- Press and hold the OFF button on the Pico wireless control for six (6) seconds until the LED on the Pico wireless control flashes.
- When successfully paired, the LEDs on the in-line load control and the Pico wireless control will flash quickly. The light load on an in-line dimmer or switch will also flash.
- Press the ON button on the Pico wireless control and verify the load control turns on the load. See the Troubleshooting section if the load does not turn on.
Install endcap and screw
Install load control
The load control must be installed in an adequately ventilated area as shown below without heat generating equipment, or obstructions. During normal operation, the in-line switch will make an audible click.
Notes:
- For optimal RF performance, no metal or other electrically conductive material should be present within 120 mm around the top and sides of the load control.
- The load control is not suitable for installation in places where it is fully enclosed in metal (e.g., metal enclosures, electrical cabinets).
Turn ON power at circuit breaker or install fuse
CAUTION: RISK OF BODILY HARM. Fan will turn on and start spinning for two (2) minutes once power is applied. Stay clear of the ceiling fan before applying power. Disconnect power before servicing. See the Troubleshooting section if the fan does not turn on. This only applies to in-line fan controls.
Operation
Error Codes – Red
IMPORTANT
- CAUTION: Use only with permanently installed fixtures.
To avoid overheating and possible damage to other equipment, do not use to control receptacles. - Install in accordance with all national and local electrical codes.
- For indoor use only between 0 °C and 40 °C (32 °F and 104 °F); 0% – 90% humidity, non-condensing.
- In-line dimmers are not rated for MLV loads and are only compatible with reverse-phase loads. Magnetic low-voltage (MLV) loads require a forward-phase device or switch for proper operation.
- The in-line fan control is only compatible with AC fans. Not for use with DC/BLDC motor fans, fans with a remote control, Wi-Fi only fans or exhaust fans (bathroom or kitchen exhaust fans). Do not connect to any other motor-operated appliance or to any lighting load type, including lighting loads on a fan.
Hereby, Lutron Electronics Co., Inc. declares that the radio equipment type HQRK-R25NE-240, HQRK-RNFSQ-240 and HQRK-R6ANS-240 are in compliance with Directive 2014/53/EU
The full text of the EU declaration of conformity is available at the following internet address: Lutron.com/cedoc
Troubleshooting
Symptoms | Probable cause |
Load does not turn on. |
|
Load does not respond to controls. |
|
|
|
|
Fan speed settings may need to be adjusted for best ceiling fan performance. Fan speed settings can be adjusted in the Lutron Designer software. |
Fan only works at high level. | Lutron in-line fan controls are designed to work with AC fans only. Confirm fan type with fan manufacturer. |
Return to Factory Settings
- Quickly triple tap the button on the load control, holding on the third tap.
- Once the load starts to flash, release the button and immediately triple tap it again.
- The load will flash and the load control will be returned to factory settings.
- When an in-line fan control is returned to its factory settings, there is no feedback from the fan load; however, the LED on the device flashes and the fan will turn off.
Limited Warranty:
www.lutron.com/europe/Service-Support/Pages/Service/Warranty
©2017–2024 Lutron Electronics Co., Inc.
Lutron, the Lutron logo, Home Works, and Pico are trademarks or registered trademarks of Lutron Electronics Co., Inc. in the US and/or other countries.
Complies with ImDA standards DA 103083
For advanced features, tips for using LEDs, the complete Home Works product line, and more, please visit www.lutron.com/homeworks
Help
- Europe: +44.(0)20.7702.0657
- Asia / Middle East: +97.160.052.1581
- U.S.A. / Canada: 1.844.LUTRON1
- Mexico: +1.888.235.2910
- India: 000800.050.1992
- Others: +1.610.282.3800
- Fax: +1.610.282.6311
FAQ
- Q: What should I do if the fan does not turn on after installation?
A: If the fan does not turn on after installation, refer to the
Troubleshooting section in the user manual for guidance. Ensure proper wiring and power connections. - Q: How can I access advanced features and tips for using LEDs?
A: For advanced features, LED usage tips, and more information, visit www.lutron.com/homeworks or contact Lutron support for assistance.
Documents / Resources
![]() |
LUTRON HQRK-R25NE-240 Series Home Works QS Inline Control [pdf] Instruction Manual HQRK-R25NE-240, HQRM-R25NE-240, HQRK-R6ANS-240, HQRM-R6ANS-240, HQRN-R6ANS-240, HQRQ-R25NE-240, HQRQ-R6ANS-240, HQRN-R25NE-240, HQRK-RNFSQ-240, HQRN-RNFSQ-240, HQRK-R25NE-240 Series Home Works QS Inline Control, HQRK-R25NE-240 Series, Home Works QS Inline Control, Works QS Inline Control, QS Inline Control, Inline Control |