PREMIER MOUNTS P5080T Tilting Low Profile Mount for Flat Panels - icon 1 BEFORE YOU BEGIN
Read these instructions completely and carefully.

WARNING
RISK OF FIRE OR ELECTRIC SHOCK

  • Turn the power off before inspection, installation, or removal.
  • Installation requires a person familiar with the construction and operation of the luminaire’s electrical system and the hazard involved. If not qualified, do not attempt installation. Contact a qualified electrician.
  • To prevent wiring damage or abrasion, do not expose wiring to the edges of sheet metal or other sharp objects.
  • Follow all NEC and local codes.

CAUTION

  • The fixture may fall down if not installed properly, follow installation instructions
  • Wear safety glasses and proper aid during installation and maintenance

Save These Instructions
Use only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
Materials Supplied With Luminaire
LIB Series Luminaire
Mounting Hardware
Multiple-Length Power Supply Cords

Prepare Electrical Wiring
Electrical Requirements
The LED fixture must be supplied with 120VAC, 50/60 Hz, and connected to an individual properly grounded branch circuit, protected by a circuit breaker. Use min. 75 C supply conductor.
Electrical Requirements
luminaire LIB Series Linear In Bay Lighting - Icon 1 The grounding and bonding of the overall system shall be done in accordance with the National Electric Code (NEC) Article 600 and local codes

Provided Components

luminaire LIB Series Linear In Bay Lighting - Fig 1

Optional Accessories

luminaire LIB Series Linear In Bay Lighting - Fig 2

Single Fixture Installation

A. Attach the mounting clips to the desired surface in a straight line using the provided screws. The distance between the two clips is determined by the length of the fixture, as noted in the chart below.luminaire LIB Series Linear In Bay Lighting - Fig 3 Note: When using magnetic mounting clips, two installed clips need to support at least 4 times the weight of the fixture (0.5Kg per fixture).
fig. 1A

Fixture Length 2ft 3ft 4ft
Mounting Width 12-16in ~300-400mm 16-24in ~400-600mm 24-36in ~600-900mm

B. Center the length of the fixture within the installed mounting clips. Press and snap the fixture into the mounting clips, with the male power connector facing the power supply drop.luminaire LIB Series Linear In Bay Lighting - Fig 4C. Install the protective cap on the female connector of the fixture.luminaire LIB Series Linear In Bay Lighting - Fig 5D. Remove the protective film on the diffuser. Connect the power cord to the male connector.luminaire LIB Series Linear In Bay Lighting - Fig 6E. Plug the power cord into a 120VAC supplied outlet.
(The maximum distance to the receptacle is determined by the length of the cord provided.)luminaire LIB Series Linear In Bay Lighting - Fig 7

Continuous Run Installation

luminaire LIB Series Linear In Bay Lighting - Fig 8
A. Repeat step A of the “Single Fixture Installation” process. Do not provide a power source to the luminaire. Do not remove the protective film. B. Determine the desired spacing between luminaires. If additional space is desired between the luminaires, continue to Section 3A. Install the brackets for the remaining fixtures in a straight line, according to Fig. 1A C. Snap the second fixture into the correlating mounting brackets. Align the mating features on the male and female connectors. Press together until a “click” is heard.
Note: If you do not hear a click, the connection has not been properly made. Disconnect and retry until a “click” is heard
Note: If the dovetails will not align, adjustment to the mounting brackets or a linking cord may be necessary.
luminaire LIB Series Linear In Bay Lighting - Fig 9
D. Repeat step 2C until the desired number of fixtures are connected in a continuous run (26 fixtures at Maximum).
Center the length of the fixtures within the installed mounting clips. Press and snap the fixture into the mounting clips, with the male power connector facing the power supply drop.
E. Connect the protective cap to the unused female connector. Remove the protective film on the diffuser. Connect the power cord to the male connector. F. Plug the power cord into a 120VAC supplied outlet.
(The maximum distance to the receptacle is determined by the length of the cord provided.)

Continuous Run Installation – Power Linking Cords

A. “Snap” the luminaires into the correlating mounting brackets, centering the length of the fixtures within the brackets.luminaire LIB Series Linear In Bay Lighting - Fig 10B. Select the “linking cord” most similar in length to the gap between the two luminaires without causing strain. Connect the linking cord to male and female connectors respectively.luminaire LIB Series Linear In Bay Lighting - Fig 11C. Connect the protective cap to the unused female connector. Remove the protective film on the diffuser. Connect the power cord to the male connector.luminaire LIB Series Linear In Bay Lighting - Fig 12D. Plug the power cord into a 120VAC supplied outlet.
(The maximum distance to the receptacle is determined by the length of cord provided.)luminaire LIB Series Linear In Bay Lighting - Fig 13

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation. CAN ICES-005 (A) / NMB-005 (A)

Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Questions
Web: products.gecurrent.com
Phone: 1-866-855-8629
All product and company names are trademarks or registered trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement by them.

luminaire LIB Series Linear In Bay Lighting - logo2021 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the General Electric Company and are used under license. Information provided is subject to change without notice. All values are designed or typical values when measured under laboratory conditions.
IND 570 | A-1026549 | REV 07/22/20

Documents / Resources

luminaire LIB Series Linear In-Bay Lighting [pdf] Installation Guide
LIB Series Linear In-Bay Lighting, LIB Series Lighting, Linear In-Bay Lighting, In-Bay Lighting, Linear Lighting, A-1026549, Lighting

References

Leave a comment

Your email address will not be published. Required fields are marked *