LUMASCAPE logoPowerSync™ PS4 Data Injector LS6550
Installation Instructions
GENERATION 2LUMASCAPE LS6550 PowerSync PS4 Data Injector

LS6550 PowerSync PS4 Data Injector

DANGER
LUMASCAPE LS6550 PowerSync PS4 Data Injector - Symbol 1 ISOLATE DEVICE FROM POWER
Failure to isolate power supply before installation or maintenance may result in fire, serious injury, electric shock, death and may damage the device.
Product Warranty is void if product is not installed as per installation instructions and in compliance with the local electrical code.

LUMASCAPE LS6550 PowerSync PS4 Data Injector - Symbol 2 LUMASCAPE LS6550 PowerSync PS4 Data Injector - Symbol 3 LUMASCAPE LS6550 PowerSync PS4 Data Injector - Symbol 4 LUMASCAPE LS6550 PowerSync PS4 Data Injector - Symbol 5
NO POWER TOOLS DO NOT USE SILICONE
ON OUTSIDE SURFACE
KEEP ELECTRONICS FREE
FROM DIRECT AND MOISTURE
DO NOT HOSE OR
PRESSURE CLEAN

READ ALL SAFETY INSTRUCTIONS FIRST

  • Follow instructions carefully; failure to do so will void warranty.
  • Ensure installation complies with local laws and applicable standards.
  • Keep PowerSync free from debris and in an easily accessible location.
  • Only use Lumascape power supplies, and leader cables.
  • Ensure mains input power is surge protected.
  • Never make connections whilst power is connected.
  • Do not make modifications or alter product.
  • Connections and LS6550 Data Injector is to be kept clean and dry at all times.
  • A PowerSync terminator is required on the last fitting of run.

Products and specifications are subject to change without notice.
IN0194-230510LUMASCAPE LS6550 PowerSync PS4 Data Injector - Figure

Control via 0-10 V or PWM Input

STEP 1
Strip the individual wire strands of the data cable as per the specification below.LUMASCAPE LS6550 PowerSync PS4 Data Injector - wire strandsSTEP 2
Pull up to remove terminal block.
LUMASCAPE LS6550 PowerSync PS4 Data Injector - Pull upSTEP 3
Using a screwdriver, loosen the screw to open the terminal and insert stranded wire, then screw back up.
LUMASCAPE LS6550 PowerSync PS4 Data Injector - screwdriverSTEP 4
Reconnect terminal block.LUMASCAPE LS6550 PowerSync PS4 Data Injector - terminal block

Label Designation
Use with 0-10 V Sinking Dimmers¹ Use with 0-10 V
Sourcing Dimmers²
PWM³
10 V Out 10 V source Not connected Not connected
Ch 1 In Channel 1 return Channel 1 + Channel 1 +
Ch 2 In Channel 2 return Channel 2 + Channel 2 +
Corn- Not connected Common – Common –

¹Mode 5, ²Mode 3, ³Mode 4
Refer to Mode Switch table

PSU Connections

STEP 1
Strip the individual wire strands of the data cable as per the specification below.LUMASCAPE LS6550 PowerSync PS4 Data Injector - PSU Connections 1STEP 2
Push Orange sliders in then pull down to remove terminal block.LUMASCAPE LS6550 PowerSync PS4 Data Injector - PSU Connections 2STEP 3
Using a screwdriver, insert into hole, push to hold open terminal while inserting stranded wire.LUMASCAPE LS6550 PowerSync PS4 Data Injector - PSU Connections 3STEP 4
Reconnect terminal block.LUMASCAPE LS6550 PowerSync PS4 Data Injector - PSU Connections 4

Color PowerSync Out Cable
2-Core
Red Power +
Black Power –

Connecting Luminaires via PowerSync Leader Cable

STEP 1
Strip the individual wire strands of the data cable as per the specification below.LUMASCAPE LS6550 PowerSync PS4 Data Injector - PowerSync Leader Cable 1STEP 2
Push Orange sliders in then pull down to remove terminal block.LUMASCAPE LS6550 PowerSync PS4 Data Injector - PowerSync Leader Cable 2STEP 3
Using a screwdriver, insert into hole, push to hold open terminal while inserting stranded wire.LUMASCAPE LS6550 PowerSync PS4 Data Injector - PowerSync Leader Cable 3STEP 4
Reconnect terminal block.LUMASCAPE LS6550 PowerSync PS4 Data Injector - PowerSync Leader Cable 4

Color PowerSync In Cable
3-Core
Red Power +
Black Power –
Orange Data +

10 Position Mode SwitchLUMASCAPE LS6550 PowerSync PS4 Data Injector - Position Mode Switch

Label  Designations
TYPICAL OPERATION MODE 0 DMX/RDM Only
1 DMX/RDM + Relay
TEST MODES 2 Test All Channels Off
3 Test All Channels On
4 Test 4 Color Cycle
5 0-10 V Sourcing
6 0-10 V Sinking
7 CRMX (Optional)
8 USB
9 Firmware Update

NOTE:

  • This function list is ONLY for Generation 2 PowerSync Injectors.
  • Generation 2 is marked on the faceplate of the label on the PowerSync Injector.

The LS6550 provides three (3) test modes for PowerSync luminaires. These require only connected luminaires and power, and no connected input signal. If an input signal is connected, the LS6550 will not respond to this signal in any of the modes below.
NOTE: These test signals apply to the relevant unit’s PowerSync output only –– it will not be passed through on the DMX/RDM connectors if multiple LS6550 units are connected.

Indicator Lights

LUMASCAPE LS6550 PowerSync PS4 Data Injector - Indicator LightsINDICATOR LIGHTS

LED Indicator Event Appearance
Power In Main input power Illuminates
Power Out Output power relay closed Illuminates
DMX Traffic DMX Traffic detected
Dimming signal detected
Flashing with signal
1.2 Hz blinking, proportional to input level
PS4 Traffic PowerSync output enabled Illuminates
Status Startup
Normal operation
3 flashes
1 flash, every 5 seconds
Circuit fault detected Over voltage
Short circuit
2 flashes, every 5 seconds
3 flashes, every 5 seconds
PowerSync fault detected
Power fault/over temperature
4 flashes, every 5 seconds
Check Relay open
Manual override
Startup/Fault detected
Power out, light off
Flashing
Illuminates
USB USB connected Illuminates/flashes with data

RJ45LUMASCAPE LS6550 PowerSync PS4 Data Injector - PlugDMX PIN DESIGNATIONS

Signal Connector Type RJ45 Std
Data + 1
Data – 2
Ground 7

Example of Low Voltage Hardwired PowerSync System

OPTION 1: Looping the PowerSync circuit through the luminaires. Not all luminaires allow for connection inside the luminaire.LUMASCAPE LS6550 PowerSync PS4 Data Injector - Low Voltage HardwiredOPTION 2: Connecting drop cables to a Trunk cable in junction boxes.LUMASCAPE LS6550 PowerSync PS4 Data Injector - Low Voltage Hardwired 2

LUMASCAPE LS6550 PowerSync PS4 Data Injector - qr codehttps://www.lumascape.com/asset/download/3199/e88a09/in0194-200902.pdf?inline=1
ARCHITECTURAL & FACADE LIGHTING

Documents / Resources

LUMASCAPE LS6550 PowerSync PS4 Data Injector [pdf] Instruction Manual
LS6550 PowerSync PS4 Data Injector, LS6550, PowerSync PS4 Data Injector, Data Injector, Injector

References

Leave a comment

Your email address will not be published. Required fields are marked *