The Extech EX820A is a professional 1000A True RMS AC Clamp Meter equipped with a built-in non-contact infrared thermometer. This device is designed for accurate electrical measurements and temperature monitoring in various applications, including electrical installations, motors, and other electrical devices. It features a large 6000 count backlit LCD display for clear readings and an ergonomically designed double-molded housing for comfortable, one-handed operation. The 43 mm (1.7 inch) jaw opening accommodates conductors up to 750 MCM or two 500 MCM cables. This meter is rated CAT IV-600 V for enhanced safety.
Saugos informacija: Always adhere to local and national safety codes. Use appropriate personal protective equipment. Do not attempt to measure voltages or currents exceeding the meter's specified limits. Ensure the meter is in good working condition before use. Refer to the safety section in the full manual for detailed precautions.

Figure 1: Extech EX820A Clamp Metras baigėsiview
2. Produkto ypatybės
- Tikrasis RMS matavimas: Pateikia tikslius nesinusoidinių bangų formų rodmenis.
- 1000A AC Current Measurement: High current capacity for demanding applications.
- Built-in IR Thermometer: Non-contact temperature measurement with laser pointer for identifying hot spots.
- LoZ (Low Impedance) Mode: Prevents false readings caused by ghost voltages.
- Žemųjų dažnių filtras (LPF): Ensures accurate measurements in electrically noisy environments.
- Įjungimo srovės matavimas: Captures motor start-up current.
- CAT IV-600V Safety Rating: High safety standard for industrial environments.
- 6000 Count Backlit LCD Display: Large, easy-to-read display with illumination for dim lighting conditions.
- Žandikaulio atidarymas: 43 mm (1.7 inches) for large conductors.
- Multimetro funkcijos: Įskaitant AC/DC Voltage, Resistance, Capacitance, Frequency, Diode, and Continuity.

Figure 2: Display with LoZ and LPF Indicators
3. Sąranka
3.1 Išpakavimas ir patikrinimas
Carefully unpack the meter and its accessories. Verify that all items listed in the 'Included Components' section are present and undamaged. If any item is missing or damaged, contact your supplier immediately.
3.2 Akumuliatoriaus įdėjimas
The EX820A requires one (1) 9V battery (included). To install or replace the battery:
- Įsitikinkite, kad skaitiklis yra IŠJUNGTAS.
- Suraskite baterijų skyriaus dangtelį matuoklio gale.
- Atsuktuvu atlaisvinkite varžtą, tvirtinantį akumuliatoriaus dangtelį.
- Remove the cover and insert the 9V battery, observing correct polarity.
- Uždėkite akumuliatoriaus dangtelį ir priveržkite varžtą.
3.3 Bandymo laidų prijungimas
Už ttage, resistance, capacitance, frequency, diode, and continuity measurements, connect the supplied test leads:
- Insert the red test lead into the VΩHz+ input jack.
- Įkiškite juodą bandymo laidą į COM įvesties lizdą.

3 pav. Įtraukti komponentai
4. Naudojimo instrukcijos
The EX820A features a rotary function switch to select the desired measurement mode. Press the 'MODE' button to cycle through functions within a single switch position (e.g., AC/DC voltage, varža/tęstinumas).
4.1 Measuring AC Current (Clamp)
- Set the rotary switch to the 'A~' position.
- Atidarykite klamp jaws by pressing the jaw release trigger.
- Apvyniokite vieną laidininką laidininkuamp nasrai. Įsitikinkite, kad nasrai yra visiškai uždaryti.
- Nuskaitykite kintamosios srovės vertę ekrane.

Figure 4: Measuring AC Current with the Clamp
4.2 AC/DC matavimas Voltage
- Prijunkite bandymo laidus, kaip aprašyta 3.3 skyriuje.
- Set the rotary switch to the 'V' position.
- Press the 'MODE' button to select AC (V~) or DC (V–) voltage.
- Apply the test probes to the circuit points where voltage turi būti išmatuotas.
- Perskaitykite ttage reikšmė ekrane.

5 pav.: Tūrio matavimastage with Test Leads
4.3 Infraraudonųjų spindulių termometro naudojimas
- Set the rotary switch to the 'IR TEMP' position.
- Point the meter's IR sensor (located at the top) towards the target surface. The laser pointer will assist in aiming.
- Read the surface temperature on the display.

Figure 6: Using the Infrared Thermometer
4.4 LoZ (Low Impedance) Mode
The LoZ function is used to eliminate ghost voltages, which can cause misleading readings. When measuring voltage in circuits where ghost voltages are suspected, select the LoZ mode to provide a low impedance path that dissipates these stray voltages.
- Set the rotary switch to the 'V LoZ' position.
- Prijunkite bandymo laidus prie grandinės.
- Perskaitykite ttage. This reading will be more accurate in the presence of ghost voltages.
4.5 žemų dažnių filtras (LPF)
The LPF function is designed for accurate measurements on variable frequency drives (VFDs) and other electrically noisy equipment. It filters out high-frequency noise that can distort True RMS readings.
- Set the rotary switch to the 'A~' or 'V~' position.
- Press the 'LPF' button to activate the Low Pass Filter. The LPF icon will appear on the display.
- Proceed with your current or voltage matavimas.
4.6 Įjungimo srovės matavimas
The Inrush function captures the maximum current surge when a motor or other inductive load starts up. This is useful for diagnosing motor starting issues.
- Set the rotary switch to the 'A~' position.
- Press the 'INRUSH' button. The meter will be ready to capture the inrush current.
- Taikykite klamp to the motor's power lead and start the motor. The meter will display the peak inrush current.
5. Priežiūra
5.1 Valymas
Wipe the meter with a dry, soft cloth. Do not use abrasives or solvents. Periodically clean the input jacks with a cotton swab and alcohol to ensure good contact.
5.2 Akumuliatoriaus keitimas
Replace the 9V battery when the low battery indicator appears on the display. Refer to Section 3.2 for battery installation instructions. Always dispose of used batteries responsibly.
5.3 Saugykla
When the meter is not in use for an extended period, remove the battery to prevent leakage. Store the meter in a cool, dry place, away from direct sunlight and extreme temperatures.
6. Problemų sprendimas
- Matuoklis neįsijungia: Patikrinkite akumuliatoriaus įdėjimą ir įsitikinkite, kad akumuliatoriaus įkrova pakankama. Jei reikia, pakeiskite.
- Rodmuo nerodomas arba rodoma „OL“ (perkrova): Ensure test leads are properly connected and making good contact. Verify the measurement range is appropriate for the input. For current measurements, ensure only a single conductor is within the clamp žandikauliai.
- Netikslūs rodmenys: Patikrinkite akumuliatoriaus tūrįtage. Ensure the correct function is selected. For voltage/current, consider using LoZ or LPF modes in noisy environments. Ensure proper contact with test points.
- IR Thermometer not working: Ensure the rotary switch is in the 'IR TEMP' position. Check for any obstructions to the IR sensor.
7. Specifikacijos
| Specifikacija | Vertė |
|---|---|
| Prekės ženklas | Extech |
| Modelio numeris | EX820A |
| Maitinimo šaltinis | Battery Powered (1 x 9V AA, included) |
| Matavimo tipas | Amperes, ttage, Resistance, Capacitance, Frequency, Temperature |
| Kintamosios srovės diapazonas | Up to 1000A True RMS |
| IR temperatūros diapazonas | Iki 270 laipsnių Celsijaus |
| Matavimo tikslumas | +/-0.5% (typical, varies by function) |
| Ekranas | 6000 Count Backlit LCD |
| Žandikaulio atidarymas | 43 mm (1.7 coliai) |
| Saugos įvertinimas | CAT IV-600V |
| Prekės svoris | 362 gramų (12.8 uncijos) |
| Gaminio matmenys (I x P x A) | 3.24 x 3.24 x 2.14 colio |
| Įtraukti komponentai | Clamp Meter, Pouch, Double-Molded Test Leads, Type-K Bead Wire Temperature Probes, 9V Battery, User Manual |
| UPC | 793950398227 |
8. Garantija ir palaikymas
8.1 Informacija apie garantiją
The Extech EX820A Clamp Skaitiklis tiekiamas su 2 metų garantija from the date of purchase. This warranty covers defects in materials and workmanship under normal use. It does not cover damage resulting from misuse, unauthorized modification, accident, or neglect. Please retain your proof of purchase for warranty claims.
8.2 Techninė pagalba
For technical assistance, troubleshooting, or service inquiries, please refer to the official Extech website or contact Extech customer support. Contact information can typically be found in the full printed manual or on the manufacturer's websvetainę.