LSI LASTEM data loggers share a range of common accessories for their installation, communication and power supply.
Sensors and data logger arms for indoor applications
When M-Log or R-Log (see Compatibility) are used in indoor applications, they can be mounted on an arm fixed on a tripod, together with a series of sensors.
![]() |
BVA305 | Sensors and data logger arm. Fixing to BVA304 tripod | |
| Dimensions | 850x610x150 mm | ||
| Number of sensors | N.6 using threaded screws + N.1 ring for ESU403.1-EST033 sensors | ||
| Weight | 0.5 Kg | ||
| Compatibility | ELO009, ELR510.1, ELO515.1 | ||
![]() |
BVA315 | Sensors and N.2 data logger arm. Fixing to BVA304 tripod | |
| Dimensions | 400x20x6 mm | ||
| Number of sensors | N.22 using threaded screws + support for N.4 ESU403.1-EST033 sensors | ||
| Weight | 1.6 Kg | ||
| Compatibility | ELO009, ELR510.1, ELO515.1 | ||
![]() |
BVA304 | Three arm tripod | |
| Occupied area size | Max 1100×1100 mm | ||
| Maximum height | 1600 mm | ||
| Weight | 1.6 kg | ||
| Bag for transportation | BWA048 | ||
Power supplies
When the data logger (see Compatibility) isn’t supplied with an ELF box, we recommend having external power supply units.
![]() |
BSC015 | Power supply converter/battery charger for indoor applications. | |
| Voltage | 230 Vca -> 9 Vdc (1,8 A) | ||
| Connection | On data logger power plug | ||
| Protection degree | IP54 | ||
| Compatibility | ELO008, ELO009, ELR510.1 | ||
![]() |
DEA260.1 | Power supply converter/battery charger for indoor applications. Free-wires cable to data logger | |
| Voltage | 230 Vca -> 14 Vdc (0,6 A) | ||
| Connection | On data logger terminal board | ||
| Protection degree | IP54 | ||
| Compatibility | E-Log, ELO008, ELR515.1, Alpha-Log | ||
![]() |
DEA251 | Power supply converter/battery charger for outdoor applications. N.2 outputs | |
| Voltage | 85…264 Vca -> 13.8 Vcc | ||
| Power | 30 W | ||
| Max output current | 2 A | ||
| Connection to sensors or data logger | On free terminals board | ||
| Protection degree | IP65 | ||
| Protections | · Short Circuit
· Overvoltage · Overcurrent |
||
| Operative temperature and humidity | -30…+70 °C ; 20…90 % | ||
| Compatibility | ELO008, E-Log, Alpha-Log, ALIEM | ||
| DYA059 | Bracket for DEA251 on poles of 45…65 mm diameter | ||
RS485 modules
Required to connect RS485 sensors (up to 3 signals) to Alpha-Log’s RS485 port.
![]() |
TXMRA0031 | Three signal RS485 active star wiring hub. The unit has three independent RS485 input and output channels, each with their own driver, which can transmit sig- nals across 1200 m of cable on each channel. | |
| Input | N.3 RS485 Channel: Data+, Data- | ||
| Output | N.1 RS485 Channel: Data+, Data- | ||
| Speed | 300…115200 bps | ||
| ESD protection | Yes | ||
| Power supply | 10…40 Vdc (not insulated) | ||
| Power consumption | 2.16 W | ||
![]() |
EDTUA2130 | Three signal RS485 active star wiring hub. | |
| Input | N.3 RS485 Channel: Data+, Data- | ||
| Output | N.1 RS485 Channel: Data+, Data- | ||
| Maximum current | 16 A | ||
| Voltage | 450 Vdc | ||
| Protection grade | IP68 | ||
Radio signals repeaters
![]() |
EZB322 | Zig-Bee radio signals repeater | |
| Mounting | Universal AC socket | ||
| Power supply | 85…265 Vac, Universal AC socket | ||
| Protection | IP52 | ||
| Environmental limits | 0…70°C | ||
| Compatibility | R-Log | ||
| EXP401 | IP64 radio signals repeater “Store and forward”. Power supply: 12 Vdc | ||
| DEA260.2 | Power supply 230->13,8V 0,6A for EXP401 repeater | ||
| EXP402 | IP65 radio signals repeater “Store and forward”. Power supply: 12 Vdc | ||
| DYA056 | Support for EXP401-402 to pole D=45…65mm | ||
| DWA505A | Cable for EXP402, L=5 m | ||
| DWA510A | Cable for EXP402, L=10 m | ||
Radio signals receiver
![]() |
EXP301 | Radio signal receiver from radio sensors or from EXP820 RS-232 Output compatible with data loggers (M/E-Log)
· Maximum number of receivable sensors 200 · Battery NiCd 9 V · Power supply 12 Vdc · Antenna included |
| DWA601A | Serial cable L=10 m for connection of EXP301 to E/M-Log data logger RS-232 port | |
| DYA056 | Support for EXP301 to pole D=45…65mm |
Batteries
External batteries are required for E-Log, Alpha-Log operation when not powered from the mains and or to increase the M-Log and R-Log battery life. Batteries are usually mounted inside ELF boxes and connected to the data logger using the terminal power supply input.
![]() |
MG0558.R | 12 V Pb 18 Ah battery | |
| Type | Rechargeable Sealed Lead-Acid battery | ||
| Dimensions | 181x76x167 mm | ||
| Weight | 6 Kg | ||
| Compatibity | ELF345-345.1-340-340.1-340.5-340.8
box |
||
![]() |
MG0560.R | 12 V Pb 44Ah battery | |
| Type | Rechargeable Sealed Lead-Acid bat- tery | ||
| Dimensions | 151x65x94 mm | ||
| Weight | 13.5 Kg | ||
| Compatibility | ELF345-345.1-340-340.1-340.5-340.8
box |
||
Mini-DIN Adapters
To connect sensors with free-wires to data loggers with min-DIN input (ELR510.1, ELO009), these adapters are needed:
![]() |
CCDCA0010 CCDCA0020 | Terminal board/mini-DIN adapter+cable | |
| N. contacts | CCDCA0010: 4 + shield
CCDCA0020: 7 + shield |
||
| Cable | L=2 m | ||
RS232 cables, USB interface
To connect data loggers to PC via RS232 or USB cable. In each pack of M-Log, E-Log and R-Log, the ELA105.R serial cable and the DEB518.R USB adapter are included.
| ELA015.R | L= 1,8 m serial cable
Included in each M-Log, E-Log and R-Log pack |
|
![]() |
DEB518.R | RS232->USB converter
Included in each M-Log, E-Log and R-Log pack |
RS485 converters, TCP/IP
To obtain a long cable (more than 1 Km) beetween the data logger and the PC. It is possible to use a RS232-485 converter. A TCP/IP connection to the Ethernet web, allows to send data to the PC within a network also connected via the Internet. These devices can be mounted inside ELF boxes.
|
|
DEA553 | Industrial secure serial port to Ethernet device server with 1xRS-232/422/485 and 2×10/100Base-T(X) | |
| Input | RS232/422/485 (DB9) | ||
| Output | Ethernet 10/100Base-T(x) Auto MDI/ MDIX | ||
| Protocols | ICMP, IP, TCP, UDP, DHCP, BOOTP, SSH, DNS, SNMP, V1/V2c, HTTPS, SMTP | ||
| Power supply | 12…48 Vdc | ||
| Consumption | 1.44 W | ||
| Operative Temperature | -40…70°C | ||
| Fixing | DIN bar | ||
| Protection | IP30 | ||
| Weight | 0,227 kg | ||
|
DEA509 | Gateway Modbus-TCP. Modbus-RTU in Modbus TCP converter | |
| Input | RS232/422/485 (DB9) | ||
| Output | Ethernet 10/100 M | ||
| ESD protection | 15 KV for serial port | ||
| Magnetic protections | 1.5 KV for Ethernet port | ||
| Power supply | 12…48 Vdc | ||
| Consumption | 200 mA @ 12Vdc, 60 mA@ 48Vdc | ||
| Operative Temperature | 0…60°C | ||
| Fixing | DIN bar | ||
| Protection | IP30 | ||
| Weight | 0.34 kg | ||
Converter RS232/RS485 – > optical fibre
![]() |
TXMPA1151 | Serial converter RS232 / optical fibre mono modal |
| TXMPA1251 | Serial converter R485 / optical fibre mono modal |
Dropping resistors
| EDECA1001 | Five 50 ohm-resistors kit (1/8 W, 0.1%, 25 ppm) to convert 4…20 mA -> 200…1000 mV |
Modem GPRS, 3G, 4G. UMTS Router. Wi-Fi Module
For remote connections, 3G-4G modems are available. Via modem, is possible to send (“push mode”) data to FTP server or, using the program P1-CommNET, to LSI LASTEM GIDAS database. These devices can be mounted inside ELF boxes.
![]() |
DEA718.3 | Modem GPRS – GSM-850 / EGSM-900 / DCS-1800 / PCS-1900 MHz Quad-Band.
GPRS class 10 |
|
| Operative temperature | -20…70°C | ||
| Power supply | 9…24 Vcc from data logger | ||
| Consumption | Sleep: 30 mA, during com. 110 mA | ||
| Weight | 0.2 kg | ||
| Compatibility | E-Log | ||
| ELA110 | Connection cable between E-Log and DEA718.3 modem | ||
| MC4101 | Fixing bar for DEA718.3 in ELF boxes | ||
| DEA609 | Modem adapter DEA718.3 / external antenna DEA611 | ||
|
TXCMA2200 | Modem 4G/LTE/HSPA/WCDMA/GPRS Quadband/class 10/class12 | |
| LTE FDD | Download speed 100Mbps Upload speed 50Mbps | ||
| Frequency band (MHz) | 850/900/1800/1900MHz | ||
| Input | 2 x RS232, 1 x RS485 | ||
| Cellular Antenna | Standard SMA female interface, 50 ohm, lighting protection(optional) | ||
| SMS | Yes | ||
| Connection cable to data logger | Included | ||
| Operative Temperature | -35…75°C | ||
| Power supply | 5…36 Vdc from data logger | ||
| Consumption @12 V | Sleep: 3 mA. Standby: 40-50 mA. Communication mode: 75-95 mA | ||
| Casing | Iron, IP30 | ||
| Mounting | DIN bar | ||
| Weight | 0.205 kg | ||
| Compatibility | Alpha-Log | ||
|
|
DEA611 | External antenna for 3G, LTE modem TXCMA2200 double gain GPRS/UMTS/LTE | |
| Frequencies | GSM/GPRS/EDGE: 850 / 900 / 1800 /
1900 MHz. UMTS/WCDMA: 2100 MHz LTE: 700 / 800 / 1800 / 2600 MHz |
||
| Free license ISM band | Field 869 MHz, UHF Frequency | ||
| Irradiation | Omnidirectional | ||
| Gain | 2 dBi | ||
| Power (max) | 100 W | ||
| Impedance | 50 Ohm | ||
| Cable | L=5 m | ||
| Fixing accessory | Included | ||
| Compatibility | TXCMA2200, DEA718.3 (adapter) | ||
| TXMPA3770 | High-Gain 2.4 GHz Wi-Fi USB adapter | ||
| Wireless data rate | Up to 150 Mbps | ||
| Port | USB 2.0 | ||
| Security | WEP, WPA, WPA2, WPA-PSK/WPA2-PSY
Encryptions |
||
| Standard | IEE802.11 | ||
| Environmental limits | 0…40°C (Not condensing) | ||
| Weight / Dimensions | 0.032 kg / 93.5 x 26 x 11 mm | ||
|
TXCRA2200 TXCRA2210 TXCRA2200.6 TXCRA2200.D | Industrial 4G/LTE Wi-Fi router, 3 different models depending on number of LAN ports (e.g. for data logger and camera with ethernet) and region covered | |
| Mobile | 4G (LTE), 3G | ||
| Max data rate | LTE: 150 Mbps. 3G: 42 Mbps | ||
| WiFi | WPA2-PSK, WPA-PSK, WEP, MAC Filter | ||
| Ethernet WAN port | N.1 (config. to LAN) 10/100 Mbps | ||
| Ethernet LAN port ()10/100 Mbps | · N.1 (TXCRA2200, TXCRA2200.6, TXCRA2200.D)
· N.4 (TXCRA2210) |
||
| Network protocols | TCP, UDP, IPv4, IPv6, ICMP, NTP, DNS, HTTP, HTTPS, FTP, SMTP, SSL v3, TLS, ARP, VRRP, PPP, PPPoE, UPnP, SSH,
DHCP, Telnet, SMNP, MQTT, Wake On Lan (WOL) |
||
| Region (operator) | · TXCRA2200, TXCRA2210: Global
· TXCRA2200.6: Europe, the Middle East, Africa, Korea, Thailand, Malaysia · TXCRA2200.D: EuropE, THE Middle East, Africa |
||
| Frequencies | · TXCRA200, TXCRA2210: 4G (LTE- FDD): B1, B2, B3, B4, B5, B7, B8,
B12, B13, B18, B19, B20, B25, B26, B28. 4G (LTE-TDD): B38, B39, B40, B41. 3G: B1, B2, B4, B5, B6, B8, B19. 2G: B2, B3, B5, B8 · TXCRA2200.6: 4G (LTE-FDD): B1, B3, B7, B8, B20, B28A. 3G: B1, B8. 2G: B3, B8 · TXCRA2200.D: 4G (LTE-FDD): B1, B3, B5, B7, B8, B20. 4G (LTE-FDD): B1, B3, B7, B8, B20. 3G: B1, B5, B8. 2G: B3, B8 |
||
| Power supply | 9…30 Vdc (<5W) | ||
| Operating temperature | -40…75°C | ||
| Weigth | 0.125 kg | ||
| Compatibility | Alpha-Log | ||
![]() |
TXANA3033 | Network directional antenna 28dBi | |
| Weight / Dimensions | 550 g / 110 x 55 mm | ||
| Cable | H=3 m | ||
| Compatibility | TXCRA2200-00.6-00.D, TXCRA2210 | ||
|
|
TXRMA4640 | Satellite Modem (GPS+GLONASS L1 freq.) Thuraya M2M | |
| Narrowband IP | UDP and TCP/IP | ||
| Frequency band | TX 1626.5 to 1675.0 MHz
R X 1518.0 to 1559.0 MHz |
||
| Typical latency | < 2 s 100 bytes | ||
| Power | 10…32 Vdc | ||
| Wi-Fi | IEEE 802.11 B/G, 2.4 GHz | ||
| Weight / Size (L x W x H) | < 900 g / 170 x 130 x 42 mm | ||
| Operative temperature | -40°C…+71°C | ||
| Support to pole | DYA062 | ||
|
|
TXCRA1300 | Industrial router 3G/LTE dual SIM, removable magnetic antenna. Input RS232/485 for communication of independent devices (e.g. data logger with serial output, camera with ethernet output) | |
| Mobile | 3G | ||
| Max data rate | 3G: 14 Mbps | ||
| SMS | Sì | ||
| Ethernet LAN port | N.1 LAN port, 10/100BT | ||
| Network protocols | PPP,PPPoE,TCP, UDP,DHCP,ICMP,NAT, DMZ, RIPv1/v2,OSPF, DDNS, VRRP, HTTP, HTTPs,DNS, ARP,QoS,SNTP,
Telnet |
||
| Power supply | 9…26 Vdc (<5W) | ||
| Operating temperature | -40…75°C | ||
| Compatibility | M-Log, E-Log | ||
| Communication ports | RS232, RS485 | ||
| Antenna | 3G/2G Omnidiretional Quad-Band included + second connector | ||
Long distance VHF radio
VHF radios allow easy, cost-free connections, several kilometers away. Via radio it is possible to connect several data log-gers with MASTER/SLAVE logic or to connect a data logger to a PC. These devices can be mounted inside ELF boxes.
|
|
TXRMA2132 | 160 MHz radio modem for PC or data logger connection, VHF-500 mW erp; includes 3 elements Yagi antenna. Transmitting part of the system, connected with ELA110+ELA105 to data logger, included in M-Log, E-Log, R-Log (MASTER). | |
| Operating band | 169.400. 169.475 MHz | ||
| Output power | 500 mW ERP | ||
| Number of channels | 12.5 – 25 – 50 kHz | ||
| Radio data rate (Tx/Rx) | 4.800 bps@12.5kHz, 9600 bps@25kHz, 19200 bps @50 kHz | ||
| Power supply | 9…32 Vcc | ||
| Consumption | 140 mA (Rx) | ||
| Operative temperature | -30…70°C | ||
| Antenna | Included. N.3 elements antenna Yagi. L=10 m cable | ||
| Line-of-sight | 7…10 km | ||
| Weight | 0.33 kg without antenna | ||
| Communication port | RS232, RS485 | ||
![]() |
TXRMA2131 | 160 MHz radio modem for PC or data logger connection, VHF-200 mW erp; includes dipole antenna. Receiving part connected with ELA105. | |
| Main features | See TXCMA2132 | ||
| Antenna | Included Dipole antenna L=5 m cable | ||
| ELA110 | Connection cable radio/data logger | ||
| ELA105 | Serial cable L=1.8 m. To be quoted to connect TXMA2131 to PC. Included in each package of M-Log, E-Log and R-Log (MASTER) for data logger connection. | ||
![]() |
DEA260.1 | 230 Vca/12Vcc power supply for radio TXRMA2131 PC side | |
| DEA605 | Serial adapter null-modem 9M/9F | ||
| DEA606 | Serial adapter null-modem 9M/9M | ||
Solar panel
For applications where mains power is not available or where a double power supply is required, the data logger can be powered by a photovoltaic panel. In these cases it is advisable to place the data logger inside an ELF345-345.1 box that in-cludes DYA115 regulator that doesn’t have to be supplied separately. When a solar panel supply is present, an external bat-tery must be housed in the ELF345 box model MG0558.R (18 Ah) or MG0560.R (44 Ah), chosen according to the autonomy required and the availability of hours of sunshine. The solar panel is mounted on a pole through a tiltable support (DYA064). Alternatively, the ELU001 box is available, which includes a 20 W panel mounted on its front panel.
![]() |
DYA101 | 60 Watt solar panel | |
| Power | 70 Wp | ||
| Operative voltage (VMP) | 16.4 V | ||
| VOC voltage | 22.4 V | ||
| Dimensions | 813×535 mm | ||
| Weight | 5.2 Kg | ||
| Tecnology | Monocristalline | ||
| Frame material | Aluminium | ||
| Cable | L=5 m | ||
| Regulator (DYA115) | · included inside ELF345-345.1 boxes
· Inside Alpha-Log |
||
![]() |
DYA064 | Tiltable support for solar panel fixing to poles of diam. 45…65 mm Weigth: 1.15 kg | |
Shockproof case to contain data loggers in portable applications
For portable applications, data loggers can be mounted inside IP66 cases to be protected against shocks, water, dust and atmospheric agents. Inside the case can be also be housed the communication device.
![]() |
ELF432 | Portable IP66 shockproof case. Complete with rechargeable battery (18 Ah) and power supply/battery charger (230 Vca/13,8 Vcc) | |
| Dimensions | 520 x 430 x 210 mm | ||
| Weight | 12 kg | ||
| Compatibility | ELO008, ELR515.1, ELO515.1, E-Log,
Alpha-Log |
||
IP66 boxes for data logger fix installations
For fix outdoor installations, data loggers can be mounted inside IP66 enclosures that give protection against shocks, water, dust and atmospheric agents. Each box houses the relative power supply system as well as specific accessories, and has the predisposition to house the communication device that can be chosen from the list of Accessories. Each box can be equip-ped with a support for pole or wall fixing.
![]() |
ELF345 | IP66 box. Complete with regulator for photovoltaic panels. Compatibility with 18 or 44 Ah batteries | |
| Power supply | From solar panel using regulator | ||
| Solar panel regulator | Included | ||
| Dimensions | H 502 x L 406 x D160 mm | ||
| Weight | 7 kg (battery excluded) | ||
| Material | Fiberglass | ||
| Compatible batteries (not included) | MG0558.R (18 Ah), MG0560.R (44 Ah) | ||
| Compatibility | ELO008, ELO515.1, E-Log, Alpha-Log | ||
![]() |
ELF345.1 | IP66 box. Complete with regulator for photovoltaic panels and 110-230 Vca battery charger power supply. Compatibility with 18 or 44 Ah batteries. | |
| Solar panel regulator | Included | ||
| Power supply | 110-230 Vca-> 13.8 Vcc
Thermal magnetic switch. Power: 50W |
||
| Dimensions | H 502 x L 406 x D 160 mm | ||
| Weight | 17.5kg (battery excluded) | ||
| Material | Fiberglass | ||
| Compatibility | ELO008, ELO515.1, E-Log, Alpha-Log | ||
![]() |
ELF345.3 | IP66 box for Alpha-Log connection to photovoltaic panels. Compatibility with 18 or 44 Ah batteries | |
| Power supply | From solar panel using regulator in- side Alpha-Log | ||
| Dimensions | H 502 x L 406 x D160 mm | ||
| Weight | 7 kg (battery excluded) | ||
| Material | Fiberglass | ||
| Compatible batteries (not included) | MG0558.R (18 Ah), MG0560.R (44 Ah) | ||
| Compatibility | Alpha-Log | ||
![]() |
ELF340 | IP66 box. Complete with 110-230Vca-> 13.8 Vcc power supply (50 W) and 2 Ah battery. Compatibility with 18 or 44 Ah batteries | |
| Power supply | 110-230 Vca-> 13.8 Vcc
Thermal magnetic switch. Power: 50W |
||
| Dimensions | H 502 x L 406 x P160 mm | ||
| Weight | 7 Kg | ||
| Material | Fiberglass | ||
| Battery | 2Ah rechargeable, included | ||
| Compatibility | ELO008, ELO515.1, E-Log, Alpha-Log | ||
![]() |
ELF340.5 | Same as ELF340, plus external connectors to use sensors with cables with con- nectors. To facilitate the connection of the sensors to the data logger
· N.8 female connectors (7-pin) for analog signals · N.2 female connectors (4-pin) for pulse signals · N.1 female connector (7-pin) for power supply |
|
![]() |
ELF340.7 | IP66 box. Complete with 110-230Vca-> 13.8 Vdc power supply and 2 Ah battery and 230/24V transformer. With N.5 Relays for actuations (MG3023.R type) and IN-OUT terminal for analogue signals | |
| Power supply | 110-230 Vac-> 13.8 Vdc 30W
230Vac/24Vac 40VA Thermal magnetic |
||
| Relay | N.5 Relays (MG3023.R type) | ||
| IN-OUT signals terminal board | Terminal for analog signals input
N.7 IN signals N.7 OUT signals |
||
![]() |
ELF340.8 | IP66 box. Complete with 110-230Vca-> 13.8 Vdc power supply and terminal board for up to N.3 RS485 signals. Compatibility with 18 or 44 Ah batteries. Used to receive digital signals | |
| Power supply | 110-230 Vca-> 13.8 Vdc 50W
Thermal magnetic |
||
| Dimensions | H 502 x L 406 x D 160 mm | ||
| Weight | 7,5 Kg | ||
| Battery | 2Ah rechargeable, included | ||
| Compatibility | ELO008, ELR515.1, ELO515.1, E-Log,
Alpha-Log |
||
![]() |
ELF344 | IP66 box. Complete with 110-230Vac-> 13.8 Vdc power supply, 2Ah battery and 230 Vac/24 Vac transformer for heated sensors | |
| Power supply | 85-264 Vac-> 13,8 Vdc 2A 30W | ||
| Transformer | 230Vac/24Vac 4.1 A 100VA | ||
| Dimensions | H 502 x L 406 x D 160 mm | ||
| Weight | 7.5 Kg | ||
| Battery | 2Ah rechargeable, included | ||
| Compatibility | ELO008, ELR515.1, ELO515.1, E-Log,
Alpha-Log |
||
![]() |
ELF347 | IP66 box. Complete with 110-230Vac-> 13.8 Vdc power supply, 2Ah battery and 85-266 Vac/24 Vdc transformer for ALL IN ONE heated version sensors | |
| Power supply | 85-264 Vac-> 13,8 Vdc 30W | ||
| Transformer | 85-266Vac/24 Vdc 6.25 A150 W | ||
| Dimensions | H 502 x L 406 x P 160 mm | ||
| Weight | 7,5 Kg | ||
| Battery | 2Ah rechargeable, included | ||
| Compatibility | E-Log, Alpha-Log | ||
![]() |
DYA074 | Support for IP66 enclosures H 502 x L 406 x P160 mm to pole Ø 45…65 mm |
![]() |
DYA072 | Support for IP66 enclosures H 502 x L 406 x P 160 mm to wall |
| DYA081 | Door lock for ELFxxx boxes | |
| MAPSA1201 | Protection tile for ELFxxx boxes. Dimensions: 500 x 400 x 230 mm | |
| SVSKA1001 | Fixing kit for A-Log in ELFxxx boxes when E-Log is already installed | |
| MAGFA1001 | Cable gland for ELF340-340.7-345-345.1-345.3-344-347 box and RJ45 / Ethernet |
Carrying cases
To transport data loggers and their accessories, LSI LASTEM supplies the following cases.
![]() |
BWA314 | Shockproof case, watertight (52x43x21 cm) for data loggers and probes Weight:3.9 kg |
| BWA319 | Shockproof case with wheels, watertight (68x53x28 cm) for data loggers and probes
Weight: 7 kg |
|
![]() |
BWA047 | Soft bag for data logger transport Weight: 0.8 kg |
![]() |
BWA048 | Bag to transport BVA304 tripod and stands Weight: 0.4 kg |
Relay
Data logger versions with terminal inputs can switch external devices on/off via their digital outputs. The voltage available at the outputs corresponds to the supply voltage of the data logger (normally 12 Vcc). In order to convert the output into a clean On/Off contact, LSI LASTEM provides relay suitable for mounting inside ELF boxes
![]() |
MG3023.R | Relay for On-Off actuation of the digital output | |
| Maximum switching voltage Minimum switching voltage Contact type
Min. switching current |
250 Vac/dc
5 V (at 10 mA) 2 PDT 10 mA (At 5 V) |
||
USB Drive
![]() |
XLA010 | USB Pen drive 3.0 Industrial Grade, Flash type MLC | |
| Capacity | 8 Mb | ||
| Power consumption | 0.7 W | ||
| Operative temperature | -40…+85 °C | ||
| Vibration | 20G @7…2000Hz | ||
| Shock | 1500G @ 0.5ms | ||
| MTBF | 3 million hours | ||
Data logger protections
| EDEPA1100 | Protection unit (SPD) for power line, single phase 230 V. | ||
| Mounting | DIN bar | ||
| Compatibility | Alpha-Log, E-Log | ||
| EDEPA1101 | Protection unit (SPD) for RS-485 communication line. | ||
| Mounting | DIN bar | ||
| Compatibility | Alpha-Log, E-Log | ||
| EDEPA1102 | Protection unit (SPD) for Ethernet communication line. | ||
| Mounting | DIN bar | ||
| Compatibility | Alpha-Log, G.Re.T.A. | ||
LSI LASTEM Srl
Via Ex SP. 161 Dosso, 9
20049 Settala (MI) Italy
Tel. +39 02 954141
Fax +39 02 95770594
Email info@lsi-lastem.com