DriveView9 Device Database
“
Specifications
- Supported Products: DriveView9
- Communication Protocols: Modbus-TCP, Modbus-RTU, LS485
- Connection Methods: RS485, USB-RS485, USB-RJ45
Product Information
DriveView9 is a software designed to communicate with specific
models of inverters. It supports various communication protocols
such as Modbus-TCP, Modbus-RTU, and LS485. Different connection
methods are required based on the model of the inverter.
Usage Instructions
1. Compatibility Check
Before connecting DriveView9, ensure that your inverter model is
compatible with the software. Refer to the compatibility table
provided in the user manual to verify compatibility.
2. Communication Type
DriveView9 supports three communication methods:
- Modbus-TCP: Industrial Ethernet Protocol
- Modbus-RTU: Standard protocol for equipment control
- LS485: Protocol specific to LSELECTRIC products
3. Connection Setup
To connect DriveView9:
- All models except M100 can be connected via RS485.
- iV5 requires a communication option (LS485/Modbus-RTU).
- For specific models like iS7, H100, S100, use USB-RJ45 cable
for connection.
4. Convertor Cable
Refer to the provided convertor cables for connecting different
models of inverters to DriveView9.
FAQ
Q: How do I install DriveView9 on my computer?
A: To install DriveView9, download the installation file from
the LSELECTRIC website and follow the installation instructions
provided in the user manual.
Q: What should I do if DriveView9 and my inverter cannot
communicate?
A: Check the compatibility table for DriveView9 and ensure that
the OS version of your inverter is supported. Use the appropriate
DriveView version that supports your inverter’s OS.
“`
DriveView9
Guidebook
1. Applicable products of Driveview9
1. Applicable products of Driveview9
– DriveView7 is a software that was used before DriveView9. Driveview7 is only supported with older inverters. Even if it is a supported model, it is only available in a lower version of the OS environment, so be careful.
– If DriveView9 and Inverter cannot communicate with each other, check the table below to see if the OS version of the inverter is compatible with DriveView9, and use DriveView that supports the Inverter OS.
iP5A
Drive iH iE5 iC5
iG5A iS5
iV5 iV5L iS7 C100 M100 G100 S100 H100
NEW OLD
Driveview 9
X X X O (Over V2.2) X O (Over V1.00) X O (Over V2.5) O O O O O O O
Driveview 7
X X X O (Over V2.2) X O (Over V1.00) X O (Over V2.5) O O O O X O O
Driveview 3.3
O O O O (Below V1.7) O X O O (Below V2.1) X O (Below V1.0) X X X X X
2. Communication type(protocol)
2. Communication type(protocol)
– DriveView9 supports three communication methods (Modbus-TCP, Modbus-RTU, LS485). – Modbus-TCP: Industrial Ethernet Protocol Developed for Wide Area Network (WAN) – Modbus-RTU : A standard protocol that is simple but can perform the functions necessary for equipment control and monitoring, and is released free of charge and widely used as a standard protocol. – LS-485 : A dedicated protocol used only among LSELECTRIC products.
3. How to connect DriveView9
3. How to connect DriveView9
1) All models except M100 can be connected by RS485. iV5 requires communication option (LS485/Modbus-RTU)
The USB-RS485 uses a two-way signal converter. Connect the USB to the computer and wire the 485 line (+), (-) to
the S+,S- on the inverter terminal.
USB to RS485 Converter
2) iS7, H100, S100 – Use the USB-RJ45 (USB to RS232 + RS232 to RJ45) cable. Connect the USB to the computer and the RJ45 to the keypad port. – See “Creating a Cable to Connect to the RJ45 Port and RS232” on the back page.
4. Convertor cable
4. Convertor cable
Product(a wide use)
Goods for sale
Photograph
specification
Application model
Manufacturer Product(a wide use) Product(a wide use) Manufacturer
: SystemBase
RJ45/RS232
USB Type A to Mini : RealSYS
Model name
converter
B
Model name
: Multi-1/USB
: CNV485U
RS232
USE: USB to RS485
USE: USB to RS2
convertor
32 converter
iS7, H100, iP5A,
iS7, H100, S100
H100
S100, iG5A, G100, C100, iV5(when
using options)
Manufacturer : LSELECTRIC USE: RS232 to USB
convertor (iS7) Item code: 64090353
iS7, H100, S100
Manufacturer : LSELECTRIC USE: RS485(RJ45) to USB
convertor(G100,M10 0) Item code: 64090354
G100(Advanced I/O), M100
4. Converter cable
[Note] Creating a cable connecting the RJ45 Port to the RS232 (for iS7, H100, S100)
– After making the cable as shown below, connect it to the KPD of the inverter controller and the 232 terminal of the PC.
TD RD Ground
RJ45 3Pin 4Pin 7 Pin
DSUB 9 Pin (Female) 2Pin 3Pin 5Pin
[Keypad RJ 45]5. DriveView9 User’s Guide
5. DriveView9 User’s Guide setting
– Run DriveView9 installed on your computer. – If driveview9 is not installed on your computer, download the ‘DriveView9’ installation file from the LSELECTRIC website (www.lselectric.co.kr) and install it on your PC. When DriveView9 runs, click [New] in the upper left corner or File > New Project in the menu.
Create a project name and inverter model, and set a directory to store the project files. also Select the product model and inverter version to connect to, and press OK. *For iS7, version 1.00 is the standard (quantitative) version.
5. DriveView9 User’s Guide
Click Settings > Modbus-RTU > Modbus-RTU right-hand Settings > Check COM-01 Int485 St Number 1 > Auto scanning port > Scan > OK > Connect
· Communication speed can be set at COM-03, initial value is 9600bps
· If you use
< this cable, Please set Baudrate 19200bps
5. DriveView9 User’s Guide
Click Tools > Options DriveView9 is language-enabled. The languages are English and Korean in two ways. You can also select a theme color. The colors are Blue, Dark, and White.
5. DriveView9 User’s Guide
Click ‘Parameter’ to read parameters from Drive. Check the parameter items you want to read.