Default credentials
- Username
- admin
- Password / access
- admin
Access: Web
Balance 20X, Balance 310X, Balance 380 and other listed models
Source (opens in a new tab)ROUTER & MODEM REFERENCE
Login addresses, default credentials, and setup instructions for Peplink equipment.
Connect to the router’s Wi-Fi or Ethernet first. These links open a new tab on your device; the address may differ if the network was reconfigured.
QUICK START
Start with the option that matches your model. Defaults apply to the factory state; use the password you chose if the device has already been set up.
Options are ordered by manufacturer documentation and coverage among the listed models. Hardware, firmware, and ISP versions can differ.
MODEL DETAILS
Passwords are case-sensitive. “Leave blank” means an empty field; “Not specified” means the source does not provide that detail. Entries without a model are brand-level references.
| Model / device | Login address | Username | Password / access | Notes & source |
|---|---|---|---|---|
| PeplinkBalance 20XRouter · Web | http://192.168.1.1 (opens in a new tab) | admin | admin | Dual-WAN business SD-WAN router: one Gigabit Ethernet WAN plus an embedded Cat-4/Cat-7 LTE modem and a FlexModule slot; the Wi-Fi variant adds 802.11ac. Genuine static admin/admin default, and Peplink forces a password change on the first successful login. Confirm the LAN IP against the device label — the manual is Balance-line-generic. Recovery & reset instructionsWith a paperclip, press and hold the recessed reset button — ~5-10 seconds for an admin-password reset (status LED blinks red twice) or ~20 seconds for a full factory reset (blinks red three times) — then release. After reboot, browse to https://192.168.1.1 and log in. |
| PeplinkBalance 310XRouter · Web | http://192.168.1.1 (opens in a new tab) | admin | admin | Enterprise/branch SD-WAN multi-WAN router (all-gigabit ports, 2.5 Gbps routing throughput, patented SpeedFusion bonding), managed via the on-box Web Admin Interface or InControl2 cloud. Genuine documented static default admin/admin; the manual recommends but does not force a change. Read-only account is user/user. Recovery & reset instructionsHold the recessed reset button on the unit to restore factory defaults, which returns the Web Admin login to admin/admin at http://192.168.1.1. Change the Admin/Read-only passwords under System > Admin Security. |
| PeplinkBalance 380Router · Web | http://192.168.1.1 (opens in a new tab) | admin | admin | Mid-tier multi-WAN SD-WAN router/firewall (configurable gigabit WAN/LAN ports, SpeedFusion bonding) positioned above the Balance 310X already covered, for medium-business deployments. Genuine documented static default admin/admin; read-only account is user/user. Recovery & reset instructionsWith a paperclip, press and hold the recessed reset button on the back panel for about 10-20 seconds until all LEDs flash, then release to restore factory defaults; from firmware 5.4+ the admin password alone can also be reset via Maintenance > Reset Admin Password on the front LCD panel. Browse to http://192.168.1.1 and log in with admin/admin. |
| PeplinkBalance OneRouter · Web | http://192.168.1.1 (opens in a new tab) | admin | admin | Dual-WAN SD-WAN router (Ethernet + optional embedded cellular) for SMB/branch use, desktop form factor with no built-in Wi-Fi radio — Peplink's entry point above the Balance 20X. Genuine static default admin/admin confirmed in the official Balance series manual. Recovery & reset instructionsWith a paperclip, press and hold the recessed reset button on the back panel for about 10-20 seconds until all LEDs flash, then release to restore factory defaults. Browse to https://192.168.1.1 and log in with admin/admin. |
| PeplinkMAX BR1Modem / gateway · Web | http://192.168.50.1 (opens in a new tab) | admin | admin | Compact mobile 4G/LTE cellular router/gateway with a single embedded modem, DIN-rail or wall mountable for vehicle/IoT deployments. Genuine static default admin/admin confirmed in the official Pepwave MAX firmware manual, on a distinct default LAN IP (192.168.50.1) from the Balance line. Recovery & reset instructionsWith a paperclip, press and hold the recessed reset button for about 10-20 seconds until all LEDs flash, then release to restore factory defaults. Browse to https://192.168.50.1 and log in with admin/admin. |
| PeplinkMAX BR2Router · Web | http://192.168.50.1 (opens in a new tab) | admin | admin | Rugged dual-SIM/dual-cellular Pepwave MAX router for M2M and fixed-site failover (on-board Wi-Fi AP, gigabit Ethernet WAN/LAN), documented in the MAX Series User Manual 8.4.0 section 2.44. Managed via the on-box Web Admin or InControl2 cloud. The static admin/admin default is transient — first logon mandates a password change. Recovery & reset instructionsRugged dual-cellular M2M/fleet LTE router. Press and hold the reset button to restore factory defaults; the Web Admin returns to admin/admin at http://192.168.50.1, after which the firmware forces a new 10-character password (mixed case plus a digit) on first logon. |
| PeplinkMAX BR2 ProRouter · Web | http://192.168.50.1 (opens in a new tab) | admin | admin | Ruggedized dual-embedded-cellular-modem router for vehicle/vessel mounting — the higher-throughput 'Pro' tier of the MAX BR2 line already covered. Genuine documented static default admin/admin in the Pepwave MAX manual, same forced-change behavior as the base BR2. Recovery & reset instructionsWith a paperclip, press and hold the recessed reset button for about 10-20 seconds until all LEDs flash, then release to restore factory defaults. Browse to http://192.168.50.1 and log in with admin/admin, after which the firmware forces a new password. |
| PeplinkMAX TransitRouter · Web | http://192.168.50.1 (opens in a new tab) | admin | admin | Pepwave MAX Transit cellular router built for vehicles and public transit (integrated GPS, Wi-Fi AP, gigabit Ethernet), covered by the MAX Series User Manual 8.4.0 Transit variant sections. Runs from the local Web Admin or InControl2. Ships with the documented admin/admin default but compels an immediate password change at first successful login. Recovery & reset instructionsIn-vehicle transit cellular router with GPS. Hold the recessed reset button until the unit reboots to factory settings; login reverts to admin/admin at http://192.168.50.1 and you must define a fresh password (minimum ten characters, upper and lower case, including a number) before the dashboard loads. |
| PeplinkMAX Transit Duo ProRouter · Web | http://192.168.50.1 (opens in a new tab) | admin | admin | A fleet/transit mobility router carrying dual embedded LTE-A Pro modems (no 5G) across 4 SIM slots plus GPS and 4 SMA cellular connectors — genuinely distinct from the already-seeded single-modem MAX Transit and the dual-5G-modem MAX BR2 Pro. Pepwave's official firmware manual states: "enter the following LAN IP address... http://192.168.50.1 (This is the default LAN IP address for Pepwave routers.) ... Username: admin Password: admin." Recovery & reset instructionsWith a paperclip, press and hold the recessed reset button for about 10-20 seconds until all LEDs flash, then release to restore factory defaults. Browse to http://192.168.50.1 and log in with admin/admin, after which the firmware forces a new password. |
| PeplinkSurf SOHO MK3Router · Web | http://192.168.50.1 (opens in a new tab) | admin | admin | SOHO router with a simultaneous dual-band 802.11ac access point, 4x Gigabit Ethernet, USB LTE/3G failover WAN and three dual-band SMA antennas. Genuine static admin/admin default; Peplink forces a password change on the first successful login. Default LAN IP is 192.168.50.1. Recovery & reset instructionsLocate the reset button on the back panel; with a paperclip press and hold it ~10 seconds for a factory reset (status LED turns red), then release. After reboot, browse to https://192.168.50.1 and log in. |
No records match these filters. Try another model or clear the filters.
GET CONNECTED
The admin password opens the router’s settings. The Wi-Fi password connects a device to the wireless network. They may be different, and an ISP or cloud account can be separate again.
Check capitalization and the device label, then use the manufacturer’s password-recovery instructions. A factory reset erases settings and may require ISP setup details; follow the instructions for your exact model.
Find your model’s manual →Router default-credential data from ssid.ai (Drumworks Ventures FZ), licensed CC BY 4.0. Adapted, organized and supplemented by Manuals+. The data is provided as is; manufacturers and ISPs can change defaults.
Additional factual entries: Austin Songer’s credential list and Clint Milner’s credential list. Each table entry links to its supporting source. Updated 2026-10-16.