Thank you for choosing the INVT EC-PG805-05 TTL incremental encoder PG expansion module. The EC-PG805-05 TTL incremental encoder PG expansion module is used with the GD880 series VFD control box to detect the TTL or RS422 incremental encoder. The expansion module monitors the rotational speed of the motor by detecting the output signal of the encoder, providing real-time speed feedback for precise speed control. This manual describes the product overview, installation, wiring, and commissioning instructions. Before installing the VFD, read through this manual carefully to ensure proper installation and running with excellent performance and powerful functions in full play.
ຄຸນສົມບັດຂອງຜະລິດຕະພັນ
- Incremental encoder multi-channel signal detection: IA+, IA -, IB+, IB -, IZ+, IZ-
- Provides power supply for encoders: 5V±5%/150mA
- Supports two input signal types: TTL differential signal input, RS422 signal input
- ສະຫນັບສະຫນູນການອ້າງອິງກໍາມະຈອນແລະຜົນຜະລິດການແບ່ງຄວາມຖີ່
- With the encoder disconnection detection function, it avoids the expansion of the system fault impact
- ສາມາດກວດພົບອຸນຫະພູມມໍເຕີຜ່ານສັນຍານເຊັນເຊີອຸນຫະພູມ KTY84/PT100
- Adopts digital filtering technology to improve electromagnetic compatibility and realize long-distance stable reception of encoder signals.
ສິນຄ້າົດແລ້ວview
ຄໍາອະທິບາຍແບບຈໍາລອງ

ຂໍ້ມູນຈໍາເພາະ

ຕາຕະລາງ 1-1 ຂໍ້ມູນຈໍາເພາະ
ຕົວກໍານົດການດ້ານວິຊາການ

ຕາຕະລາງ 1-2 ຕົວກໍານົດການດ້ານວິຊາການ
ໝາຍເຫດ: The Disconnection detection function is only supported when the motor is running.
ໂຄງສ້າງ
Figure 1-2 Component diagram

ຕາຕະລາງ 1-3 ລາຍລະອຽດອົງປະກອບ

ການຕິດຕັ້ງແລະສາຍໄຟ
ລະມັດລະວັງການຕິດຕັ້ງ
Required tools: Phillips screwdriver PHl, straight screwdriver SL3

ຕາຕະລາງ 2-1 Screw torque requirements

ຂະໜາດ
The dimensions of the PG expansion module are 73.5x 103 x 34 mm (W*H*D).

ຄໍາແນະນໍາການຕິດຕັ້ງ

It is recommended to place the PG expansion module in expansion slot 1 of the control box. The following is an example ຂອງການຕິດຕັ້ງຢູ່ຊ່ອງ 1.
ຂັ້ນຕອນທີ 1: ວາງໂມດູນການຂະຫຍາຍຢູ່ໃນຕໍາແຫນ່ງທີ່ສອດຄ້ອງກັນຂອງຊ່ອງໃສ່ການຂະຫຍາຍກ່ອງຄວບຄຸມ 1, ຈັດວາງມັນກັບຊ່ອງສຽບ, ແລະຫຼັງຈາກນັ້ນ buckle ມັນເຂົ້າກັນ.
ຂັ້ນຕອນທີ 2: Align the expansion module positioning hole with the positioning stud.
ຂັ້ນຕອນທີ 3:F: Fix with an M3 screw. The installation is complete.
ໝາຍເຫດ
- ໂມດູນຂະຫຍາຍແລະກ່ອງຄວບຄຸມແມ່ນເຊື່ອມຕໍ່ໄຟຟ້າຜ່ານຊ່ອງສຽບ. ກະລຸນາຕິດຕັ້ງພວກມັນຢູ່ໃນສະຖານທີ່.
- ເພື່ອຮັບປະກັນການເຮັດວຽກທີ່ຫນ້າເຊື່ອຖືຂອງໂມດູນການຂະຫຍາຍແລະຕອບສະຫນອງຄວາມຕ້ອງການຂອງ EMC, ກະລຸນາແຫນ້ນ screws ຕາມແຮງບິດທີ່ແນະນໍາສໍາລັບຫນ້າດິນທີ່ເຊື່ອຖືໄດ້.
ຄໍາແນະນໍາກ່ຽວກັບການຖອດອຸປະກອນ
You disassemble the module by reversing the order of steps described in section 2.3 Installation instructions.
ຂັ້ນຕອນທີ 1: Disconnect all power supplies and disassemble all cables connected to the expansion module.
ຂັ້ນຕອນທີ 2: Use a Phillips screwdriver PHl to remove the grounding screws of the expansion module.
ຂັ້ນຕອນທີ 3: Lift the expansion module out of the control box, positioning stud, and pull it out to a suitable position. Disassembly is complete.
ສະຖານີສາຍໄຟຂອງຜູ້ໃຊ້


ໝາຍເຫດ
- The number of the PG extension module that supports the KTY84 type and that supports the PT100 type are different. Please note this when placing an order.
- The PG expansion module supports one PT100 or three PT100s for use in series.
ຕາຕະລາງ 2-3 X4 ນິຍາມຟັງຊັນຂອງເຄື່ອງໝາຍປາຍທາງ

Table 2-4 Function definition of RJ45 interfaces X1-X2

Figure 2-3 External wiring diagram when using EC-PG805-05

ໝາຍເຫດ: For the PT100 temperature sensor application (in a 3-channel series connection), J3 should be shortened.
ຂໍ້ຄວນລະວັງສາຍໄຟ
ໝາຍເຫດ
- ສໍາລັບສາຍໄຟຕົວເຂົ້າລະຫັດພາຍໃນຕູ້, ໃຫ້ແຍກພວກມັນອອກຈາກສາຍໄຟລົບກວນທີ່ເຂັ້ມແຂງ (ເຊັ່ນ: ສາຍໄຟ) ທີ່ມີໄລຍະຫ່າງທີ່ແນະນໍາ 30 ຊມ.
- ສໍາລັບສາຍໄຟຕົວເຂົ້າລະຫັດຢູ່ນອກຕູ້, ຫຼີກເວັ້ນການສາຍຂະຫນານກັບສາຍໄຟແລະຫຼີກເວັ້ນການປະກອບເປັນຮູບວົງແຫວນ. ຖ້າເງື່ອນໄຂອະນຸຍາດ, ແນະນໍາໃຫ້ໃຊ້ທໍ່ໂລຫະສໍາລັບສາຍໄຟ.
- To ensure high anti-interference capability in closed-loop control, you need to use a shielded wire for encoder cables and ground both ends of the cable, that is, connect the shielding layer on the motor side to the motor housing, and connect the shielding layer on the PG module side to the PE terminal.
ຄໍາແນະນໍາການມອບຫມາຍ


Table 3-1 Function code parameters related to PG expansion module.


ໝາຍເຫດ: For other parameter settings of the EC-PG805-05 TTL incremental encoder PG expansion module, see the software manuals of the GD880 series inverter unit.
ເອກະສານ / ຊັບພະຍາກອນ
![]() |
invt EC-PG805 TTL Incremental Encoder PG Expansion Module [pdf] ຄູ່ມືຜູ້ໃຊ້ 66001-01189, EC-PG805 TTL Incremental Encoder PG Expansion Module, EC-PG805, TTL Incremental Encoder PG Expansion Module, Incremental Encoder PG Expansion Module, Encoder PG Expansion Module, PG Expansion Module, Expansion Module, Module |