1.1 ລາຍລະອຽດ
D1h–D8h drives have 3 IGBT modules. If the brake option is present, the drive also includes a brake IGBT module. This IGBT module replacement kit contains all components required to install 1 replacement IGBT module or 1 brake IGBT module.

ແຈ້ງການ
SPARE PARTS COMPATIBILITY
recommends replacement of all IGBT modules or all brake IGBT modules, when 1 or more modules fail.
- ເພື່ອໃຫ້ໄດ້ຜົນດີທີ່ສຸດ, ແທນທີ່ໂມດູນດ້ວຍພາກສ່ວນຕ່າງໆຈາກຕົວເລກດຽວກັນ.

1.2 ເລກຊຸດ
ໃຊ້ຄໍາແນະນໍາເຫຼົ່ານີ້ກັບຊຸດຕໍ່ໄປນີ້.
ຕາຕະລາງ 1: ຕົວເລກສໍາລັບຊຸດການທົດແທນໂມດູນ IGBT

ເລກຊຸດ ລາຍລະອຽດຊຸດ
176F3362 IGBT dual module 300 A 1200 V T4/T5 drive
176F3363 IGBT dual module 450 A 1200 V T2/T4/T5 drive
176F3364 IGBT dual module 600 A 1200 V T2/T4/T5 drive
176F3365 IGBT dual module 900 A 1200 V T2/T4/T5 drive
176F3366 IGBT brake module 450 A 1700 V
176F3367 IGBT brake module 650 A 1700 V
176F3422 IGBT dual module 300 A 1700 V T7 drive
176F3423 IGBT dual module 450 A 1700 V T7 drive
176F3424 IGBT dual module 450 A 1700 V T7 drive PP2
176F3425 IGBT dual module 650 A 1700 V T7 drive PP2
176F4242 IGBT dual module 450 A 1200 V T4/T5 drive

1.3 ລາຍການທີ່ສະໜອງໃຫ້

ພາກສ່ວນຕໍ່ໄປນີ້ແມ່ນບັນຈຸຢູ່ໃນຊຸດ.

  • 1 IGBT module
  • Syringe of thermal grease
  • Hardware for busbar mounting
  • fasteners

ການຕິດຕັ້ງ

2.1 ຂໍ້ມູນຄວາມປອດໄພ
ແຈ້ງການ
ບຸກຄະລາກອນທີ່ມີຄຸນວຸດທິ
ມີພຽງແຕ່ບຸກຄະລາກອນທີ່ມີຄຸນວຸດທິເທົ່ານັ້ນທີ່ໄດ້ຮັບອະນຸຍາດໃຫ້ຕິດຕັ້ງສ່ວນທີ່ອະທິບາຍໄວ້ໃນຄໍາແນະນໍາໃນການຕິດຕັ້ງເຫຼົ່ານີ້.
– ການ​ຖອດ​ແລະ​ປະກອບ​ໃໝ່​ຂອງ​ໄດ​ຕ້ອງ​ເຮັດ​ຕາມ​ຄູ່​ມື​ການ​ບໍລິການ​ທີ່​ສອດ​ຄ້ອງ​ກັນ.

ຄຳ ເຕືອນ-icon.png ຄຳເຕືອນ ຄຳ ເຕືອນ-icon.png
ອັນຕະລາຍຈາກໄຟຟ້າຊັອດ
VLT® FC series drives contain dangerous voltages ເມື່ອເຊື່ອມຕໍ່ກັບ mains voltage. ການຕິດຕັ້ງທີ່ບໍ່ຖືກຕ້ອງ, ແລະການຕິດຕັ້ງຫຼືການບໍລິການທີ່ມີການເຊື່ອມຕໍ່ໄຟຟ້າ, ສາມາດເຮັດໃຫ້ເສຍຊີວິດ, ການບາດເຈັບທີ່ຮ້າຍແຮງ, ຫຼືອຸປະກອນລົ້ມເຫລວ.
– Only use qualified electricians for the installation.
– Disconnect the drive from all power sources before installation or service.
– Treat the drive as live whenever the mains voltage ແມ່ນເຊື່ອມຕໍ່.
– Follow the guidelines in these instructions and local electrical safety regulations.

ຄຳ ເຕືອນ-icon.png ຄຳເຕືອນ ຄຳ ເຕືອນ-icon.png
ເວລາອອກ (20 ນາທີ)
ໄດຣຟ໌ປະກອບດ້ວຍຕົວເກັບປະຈຸ DC-link, ເຊິ່ງສາມາດສາກໄຟໄດ້ເຖິງແມ່ນວ່າຈະບໍ່ໄດ້ເປີດໄຟ. ສູງ voltage ສາມາດຢູ່ໄດ້ເຖິງແມ່ນວ່າໃນເວລາທີ່ໄຟຕົວຊີ້ວັດການເຕືອນໄພປິດ.
ຄວາມລົ້ມເຫຼວຂອງການລໍຖ້າ 20 ນາທີຫຼັງຈາກພະລັງງານໄດ້ຖືກໂຍກຍ້າຍອອກກ່ອນທີ່ຈະປະຕິບັດການບໍລິການຫຼືວຽກງານສ້ອມແປງສາມາດເຮັດໃຫ້ເສຍຊີວິດຫຼືບາດເຈັບສາຫັດ.
- ຢຸດ​ມໍ​ເຕີ​.
– Disconnect AC mains, permanent magnet type motors, and remote DC-link supplies, including battery back-ups, UPS, and DC-link connections to other drives.
– Wait 20 minutes for the capacitors to discharge fully before performing any service or repair work.
- ການ​ວັດ​ແທກ voltage ລະດັບເພື່ອກວດສອບການລົງຂາວຢ່າງເຕັມທີ່.

ແຈ້ງການ
ການກວດໄຟຟ້າ
ການໄຫຼຂອງໄຟຟ້າສະຖິດສາມາດເຮັດໃຫ້ອົງປະກອບເສຍຫາຍ.
– ຮັບ​ປະ​ກັນ​ການ​ໄຫຼ​ອອກ​ກ່ອນ​ທີ່​ຈະ​ສໍາ​ຜັດ​ກັບ​ອົງ​ປະ​ກອບ​ຂັບ​ພາຍ​ໃນ​, ສໍາ​ລັບ​ການ​ຍົກ​ຕົວ​ຢ່າງ​ample ໂດຍການສໍາຜັດກັບພື້ນດິນ, ດ້ານ conductive ຫຼືໂດຍການໃສ່ສາຍແຂນທີ່ມີດິນ.

2.2 ການຕິດຕັ້ງໂມດູນ IGBT
ແຈ້ງການ
THERMAL INTERFACE
A proper thermal interface is required between the IGBT module and heat sink. Failure to follow these instructions results in a poor thermal bond and causes premature IGBT failure.
– ຮັບປະກັນວ່າສະພາບແວດລ້ອມບໍ່ມີຂີ້ຝຸ່ນ ແລະສິ່ງປົນເປື້ອນໃນອາກາດ ໃນຂະນະທີ່ໃຊ້ນໍ້າມັນລະບາຍຄວາມຮ້ອນ.

ແຈ້ງການ
HEAT SINK DAMAGE
A damaged heat sink can cause a drive to malfunction. A clean, undamaged mounting surface allows proper thermal dissipation.
– ລະວັງບໍ່ໃຫ້ເກີດຮອຍຂີດຂ່ວນ ຫຼື ຄວາມເສຍຫາຍຂອງແຜ່ນລະບາຍຄວາມຮ້ອນໃນເວລາທໍາຄວາມສະອາດ ແລະ ໃຫ້ບໍລິການຂັບ.

ເບິ່ງຄູ່ມືການບໍລິການສໍາລັບຂັ້ນຕອນການຖອດ IGBT. ເພື່ອຕິດຕັ້ງໂມດູນ IGBT ທົດແທນ, ໃຫ້ໃຊ້ຂັ້ນຕອນຕໍ່ໄປນີ້.

  1. Clean the heat sink using a cloth and solvent or isopropyl alcohol to remove debris and remaining thermal grease.
  2. To ensure that the thermal grease is not expired, check the expiration date on the packaging. If expired, order a new syringe of thermal grease (p/n 177G5463).
  3. With the syringe, apply a layer of thermal grease to the bottom of the IGBT module in the pattern shown in Illustration 1.
    ມັນບໍ່ຈໍາເປັນຕ້ອງໃຊ້ syringe ທັງຫມົດ, ແຕ່ grease ຄວາມຮ້ອນເກີນບໍ່ແມ່ນບັນຫາ.
    Danfoss FC Series VLT IGBT Module - Installation 1ຮູບປະກອບ 1: IGBT ຮູບແບບ Grease ຄວາມຮ້ອນ
    1. Bottom surface of IGBT module
    2. Thermal grease
  4. Place the IGBT module on the heat sink, and twist it back and forth to spread the thermal grease evenly on the IGBT and the heat sink surface.
  5. Align the mounting holes in the IGBT module with the holes in the heat sink.
  6. Insert the mounting screws and hand tighten them. The IGBT module requires either 4 or 10 screws to fasten it to the heat sink.
  7. Using a manual torque wrench to avoid over torquing the screw, follow the fastener tightening sequence shown in Illustration 2. Slowly tighten (maximum 20 RPM) all screws to 50% of the torque values listed in Table 2.
  8. Repeat the same tightening sequence and slowly tighten (maximum 5 RPM) all screws to 100% of the torque value.
  9. Tighten the busbar connection terminals to the torque value listed in Table 2.
    Danfoss FC Series VLT IGBT Module - Installation 2ພາບປະກອບ 2: ລຳດັບການຍຶດຕິດ IGBT

ຕາຕະລາງ 2: ຄ່າຂອງແຮງບິດເຄັ່ງຕຶງ ແລະ ລໍາດັບ

ເລກຊຸດ Mounting torque [Nm (in-lb)] Busbar connection torque [Nm (in-lb)] ແຜນວາດ Screw tightening ຄໍາສັ່ງ
176F3362 3.3 (29) 4.0 (35) A 1-2-3-4
176F3363 3.3 (29) 4.0 (35) A 1-2-3-4
176F3364 3.5 (31) 9.0 (80) B 1-2-3-4-5-6-7-8-9-10
176F3365 3.5 (31) 9.0 (80) B 1-2-3-4-5-6-7-8-9-10
176F3366 3.3 (29) 4.0 (35) A 1-2-3-4
176F3367 3.5 (31) 9.0 (80) B 1-2-3-4-5-6-7-8-9-10
176F3422 3.3 (29) 4.0 (35) A 1-2-3-4
176F3423 3.3 (29) 4.0 (35) A 1-2-3-4
176F3424 3.5 (31) 9.0 (80) B 1-2-3-4-5-6-7-8-9-10
176F3425 3.5 (31) 9.0 (80) B 1-2-3-4-5-6-7-8-9-10
176F4242 3.3 (29) 4.0 (35) A 1-2-3-4

Danfoss A / S
Ulsnaes 1
DK-6300 Graasten
drives.danfoss.com

ຂໍ້ມູນໃດໆ, ລວມທັງ, ແຕ່ບໍ່ຈໍາກັດຂໍ້ມູນກ່ຽວກັບການເລືອກຜະລິດຕະພັນ, ຄໍາຮ້ອງສະຫມັກຫຼືການນໍາໃຊ້ຂອງມັນ, ການອອກແບບຜະລິດຕະພັນ, ນ້ໍາຫນັກ, ຂະຫນາດ, ຄວາມອາດສາມາດຫຼືຂໍ້ມູນດ້ານວິຊາການອື່ນໆໃນຄູ່ມືຜະລິດຕະພັນ, ຄໍາອະທິບາຍລາຍການ, ການໂຄສະນາ, ແລະອື່ນໆ. ແລະບໍ່ວ່າຈະມີຢູ່ໃນລາຍລັກອັກສອນ, ທາງປາກ, ອີເລັກໂທຣນິກ, ອອນໄລນ໌ຫຼືໂດຍຜ່ານການດາວໂຫຼດ, ຈະຖືກພິຈາລະນາເປັນຂໍ້ມູນ, ແລະພຽງແຕ່ຜູກມັດຖ້າແລະໃນຂອບເຂດ, ການອ້າງອິງຫຼືການອ້າງອິງຢ່າງຈະແຈ້ງ. Danfoss ບໍ່ສາມາດຍອມຮັບຄວາມຮັບຜິດຊອບໃດໆສໍາລັບຄວາມຜິດພາດທີ່ເປັນໄປໄດ້ໃນລາຍການ, ແຜ່ນພັບ, ວິດີໂອແລະອຸປະກອນອື່ນໆ. Danfoss ສະຫງວນສິດໃນການປ່ຽນແປງຜະລິດຕະພັນຂອງຕົນໂດຍບໍ່ມີການແຈ້ງໃຫ້ຊາບ. ອັນນີ້ຍັງໃຊ້ໄດ້ກັບຜະລິດຕະພັນທີ່ສັ່ງແຕ່ບໍ່ໄດ້ຈັດສົ່ງໂດຍໃຫ້ວ່າການປ່ຽນແປງດັ່ງກ່າວສາມາດເຮັດໄດ້ໂດຍບໍ່ມີການປ່ຽນແປງຮູບແບບ, ເຫມາະຫຼືຫນ້າທີ່ຂອງຜະລິດຕະພັນ. ເຄື່ອງໝາຍການຄ້າທັງໝົດໃນເອກະສານນີ້ແມ່ນຊັບສິນຂອງບໍລິສັດ Danfoss A/S ຫຼື Danfoss group. Danfoss ແລະສັນຍາລັກ Danfoss ແມ່ນເຄື່ອງຫມາຍການຄ້າຂອງ Danfoss A/S. ສະຫງວນລິຂະສິດທັງໝົດ.

Danfoss FC Series VLT IGBT Module - ບາໂຄດ 1
Danfoss A/S © 2023.10
AN341428219214en-000201 / 130R0383 | 6
Danfoss FC Series VLT IGBT Module - ບາໂຄດ 2

ເອກະສານ / ຊັບພະຍາກອນ

Danfoss FC Series VLT IGBT Module [pdf] ຄູ່ມືການຕິດຕັ້ງ
176F3362, 176F3363, 176F3364, 176F3365, 176F3366, 176F3367, 176F3422, 176F3423, 176F3424, 176F3425, ຊຸດ. ໂມດູນ IGBT, ຊຸດ FC, ໂມດູນ VLT IGBT, ໂມດູນ IGBT, ໂມດູນ

ເອກະສານອ້າງອີງ

ອອກຄໍາເຫັນ

ທີ່ຢູ່ອີເມວຂອງເຈົ້າຈະບໍ່ຖືກເຜີຍແຜ່. ຊ່ອງຂໍ້ມູນທີ່ຕ້ອງການຖືກໝາຍໄວ້ *