LIVOLTEK logo1

Quick Installation Guide

– All-In-One Energy Storage System
I                       Preparation Tools
LIVOLTEK Hyper-5000 All-In-One Energy Storage System a1

Bit ø10 Hammer drill

LIVOLTEK Hyper-5000 All-In-One Energy Storage System a2

Rubber hammer

LIVOLTEK Hyper-5000 All-In-One Energy Storage System a3

Claw safety hammer

LIVOLTEK Hyper-5000 All-In-One Energy Storage System a4

Cross screwdriver

LIVOLTEK Hyper-5000 All-In-One Energy Storage System a5

Slotted screwdriver

LIVOLTEK Hyper-5000 All-In-One Energy Storage System a6

Spirit level\Marker

LIVOLTEK Hyper-5000 All-In-One Energy Storage System a7

Tape ruler

LIVOLTEK Hyper-5000 All-In-One Energy Storage System a8

Insulation tape

LIVOLTEK Hyper-5000 All-In-One Energy Storage System a9

Dustproof cover

LIVOLTEK Hyper-5000 All-In-One Energy Storage System a10

Protective glasses

LIVOLTEK Hyper-5000 All-In-One Energy Storage System a11

Euro terminal crimping tool

LIVOLTEK Hyper-5000 All-In-One Energy Storage System a12

Wire stripper

LIVOLTEK Hyper-5000 All-In-One Energy Storage System a13

Diagonal pliers

LIVOLTEK Hyper-5000 All-In-One Energy Storage System a14

OT terminals press clamp

LIVOLTEK Hyper-5000 All-In-One Energy Storage System a15

Crimping tool (RJ45)

LIVOLTEK Hyper-5000 All-In-One Energy Storage System a16

Utility knife

LIVOLTEK Hyper-5000 All-In-One Energy Storage System a17

Marker pen

LIVOLTEK Hyper-5000 All-In-One Energy Storage System a18

Hydraulic tong

LIVOLTEK Hyper-5000 All-In-One Energy Storage System a19

(Range ≥1100V DC)
Multimeter

LIVOLTEK Hyper-5000 All-In-One Energy Storage System a20

AC/DC clamp-on ammeter

II                     Packing List
LIVOLTEK Hyper-5000 All-In-One Energy Storage System b1

Inverter *1

LIVOLTEK Hyper-5000 All-In-One Energy Storage System b2

Inverter Bracket *1

LIVOLTEK Hyper-5000 All-In-One Energy Storage System b3

Side Frames *2

LIVOLTEK Hyper-5000 All-In-One Energy Storage System b4

Battery Bracket *1

LIVOLTEK Hyper-5000 All-In-One Energy Storage System b5

Middle Cover & Bottom *1

LIVOLTEK Hyper-5000 All-In-One Energy Storage System b6

Connection Bracket *1

LIVOLTEK Hyper-5000 All-In-One Energy Storage System b7

Wi-Fi Dongle *1

LIVOLTEK Hyper-5000 All-In-One Energy Storage System b8

Grid Connector *1

LIVOLTEK Hyper-5000 All-In-One Energy Storage System b9

Multi COM connector *1

LIVOLTEK Hyper-5000 All-In-One Energy Storage System b10

EPS Connector *1

LIVOLTEK Hyper-5000 All-In-One Energy Storage System b11

Battery power Connectors *2

LIVOLTEK Hyper-5000 All-In-One Energy Storage System b12

Expansion Bolts *10

LIVOLTEK Hyper-5000 All-In-One Energy Storage System b13

Screws *16

LIVOLTEK Hyper-5000 All-In-One Energy Storage System b14

PE terminal *1

LIVOLTEK Hyper-5000 All-In-One Energy Storage System b15

BMS Connector *1

LIVOLTEK Hyper-5000 All-In-One Energy Storage System b16

CT *1
(Current Transformer)

LIVOLTEK Hyper-5000 All-In-One Energy Storage System b17

DRM Connector *1

LIVOLTEK Hyper-5000 All-In-One Energy Storage System b18

PV Connectors *2 or 4

LIVOLTEK Hyper-5000 All-In-One Energy Storage System b19

Documents

LIVOLTEK Hyper-5000 All-In-One Energy Storage System b20

Battery *1

Notice:  > For all-in-one application, there are three packages(Inverter &Middle cover kit & Battery).
Please check and contact your distributor in case of any damaged or missing components.
> For all-in-one application, the battery can only be LIVOLTEK Li-ion battery.
> This file is for quick guidance installation only. For details, please refer to the User Manual.

III                     Installation instructions

(A) Installation Requirement

LIVOLTEK Hyper-5000 All-In-One Energy Storage System c1

(B) Installation Procedure

(1) Assemble the Brackets
Connect the three brackets with four screws.

LIVOLTEK Hyper-5000 All-In-One Energy Storage System c2

  1. Battery bracket
  2. Connection bracket
  3. Inverter bracket

(2) Fix the brackets to the wall
Mark positions of brackets with a marker pen ,then drill holes with a driller.

LIVOLTEK Hyper-5000 All-In-One Energy Storage System c3

Dimensions For Drilling Holes:

LIVOLTEK Hyper-5000 All-In-One Energy Storage System c4

  1. The total number of screws is 10, and the diameter of the screw is 12/8 mm.
    Make sure the drilling depth of holes is at least 70mm when you drill holes with the drill.

(3) Remove upper cover from the battery

LIVOLTEK Hyper-5000 All-In-One Energy Storage System c5

(4) Mount the battery on the bracket

LIVOLTEK Hyper-5000 All-In-One Energy Storage System c6

(5) Mount the bottom of Middle cover kit

LIVOLTEK Hyper-5000 All-In-One Energy Storage System c7

Note:
Secure the bottom of the middle cover kit to the connection bracket and the battery with 5 screws.

(6) Mounting the Inverter

LIVOLTEK Hyper-5000 All-In-One Energy Storage System c8

Note:
Secure the inverter to the bracket with 1 screw.

(7) Install side frames on both sides and buckle the Middle Cover

LIVOLTEK Hyper-5000 All-In-One Energy Storage System c9

Buckle the middle-cover to the all-in-one system after all electrical connection and settings are done.
DO NOT forget to ground the Inverter and Battery.
Ensure to read and follow the safety instructions in the user manual.

IV                     Wiring Diagram

(A) Electrical Connection Overview

(1) DC SPD: 650V
(2) DC fuse: 30A
(3) DC isolator: 20A

Warning Icon 16 Notice:

This diagram indicates the wiring structure instead of the electric wiring standard of hybrid inverter.

  1. For batteries with attached breaker, the external DC breaker could be omitted.
  2. The recommended values in the table are for reference only.
  3. The actual values must comply with local standard and actual conditions.
  4. Only for lithium battery which has BMS communication.
  5. Direction of the CT cannot be connected in reverse, please follow “→Inverter” direction to do the connection

(4) AC breaker for grid : 63A AC breaker;
(5) AC breaker for inverter : 32A AC breaker;
(6) AC breaker for load : 32A AC breaker;

LIVOLTEK Hyper-5000 All-In-One Energy Storage System d1

  1. PE panels
    PV1 + PV2 max 7.5kw
  2. DC BOX
  3. Hybrid inverter
  4. It can be extended up to 50 meters
  5. Arrow point to the inverter
  6. ESKOM
  7. AC BOX
  8. On Grid Home Load
  9. Back Up Load
  10. Resister
  11. Battery

(B) System Connection Diagram (Applies to most countries)

LIVOLTEK Hyper-5000 All-In-One Energy Storage System d2

  1. PV String
  2. Battery
    a) If the battery is integrated with a readily accessible internal DC breaker, no additional DC breaker is required.
  3. Meter/CT
  4. GRID
  5. Hybrid Inverter
  6. BAT
  7. BMS
  8. BACK-UP
  9. Distribution Box
  10. RS485
  11. Smart Meter
  12. RCD
  13. PE BAR
  14. Utility Grid
  15. On-Grid Loads
  16. Back-up Loads

Warning Icon 16 Notice:

  • N and PE wiring via ON-GRID and BACK-UP ports of the inverter are different based on the regulation requirements of different regions.
  • Refer to the specific requirements of local regulations.
  • Ensure that the grounding of BACK-UP is correctly and tightened. Otherwise, the BACK-UP function may be abnormal in case of grid failure.
V                     PE Cable Connection

(A) Please prepare the cable before connecting as follows.

No.

Cable Cross Section Cable diameter (mm)
1 PV cables 4mm ² – 6mm²

12~10 AWG

2

AC cables 4mm ² – 6mm² 12~10 AWG
3 Battery power cables 25mm ²

4 AWG

4

PE cable 4mm ² – 6mm²

10 AWG

Warning Icon 16 Notice:

  • Do not work with power on. All operations, cables and parts specification during the electrical connection shall be in compliance with local laws and regulations.
  • Disconnect the DC switch of the inverter to power o ff the inverter before any electrical connections.

(B) Unacceptable Installations

LIVOLTEK Hyper-5000 All-In-One Energy Storage System e1

a) Grid
b) PV array
c) Battery
d) EPS Port
e) Generator
f) Incompatible Battery

Warning Icon 16 Notice:

  • Please avoid the following installations which will damage the system or the Inverter.
  • Any damage caused will not be covered by the warranty policy.

(1) Multi inverters cannot be connected in parallel.
(2) Single PV string cannot be connected to multiple inverters.
(3) One battery bank cannot be connected to multiple inverters.
(4) The EPS (backup) side cannot be connected to the grid.
(5) The inverter cannot be connected to any AC generator directly.
(6) The inverter cannot be connected to any incompatible batteries.

(C) External Grounding (PE Cable) Connection

LIVOLTEK Hyper-5000 All-In-One Energy Storage System e2

Warning Icon 16 Notice

  • Ensure that the PE cable is securely connected.
    Otherwise, electric shocks may occur.
  • Do not connect the neutral wire to the enclosure as a PE cable.
    Otherwise, electric shocks may occur.
VI                     PV Cable Connection

Step 1  Remove an appropriate length of the insulation layer from the PV Strings power cables.
Step 2  Connect the red wire to the positive metal terminal, and the black to the negative and crimp them using a crimping tool.
Step 3  Insert the crimped positive and negative power cables into the corresponding connectors until a “click” sound is heard.
Step 4  Tighten the locking nuts on the positive and negative connectors.
Step 5  Measure the voltage of every route Strings using a multimeter. Ensure that the polarities of the DC input power cables are correct.
Step 6  Insert the positive and negative connectors into their corresponding terminals of the inverter until a click sound is heard.

LIVOLTEK Hyper-5000 All-In-One Energy Storage System f1

a) Positive metal terminals
b) Negative metal terminals

VII                     AC GRID Connection

Step 1  Take out the AC terminal from the package box and uninstall it as below chart.
Step 2  Put the AC cables through the terminal cap, threaded sleeve in sequence.
Step 3  Remove the cable jackets and strip the wire insulation then insert cables into connection terminals according to polarities indicates on it and tighten the screws.
Step 4  Push threaded sleeve onto the connection terminal until both are locked tightly. Then screw up the terminal cap.
Step 5  Unscrew the cap on the Grid port. Then insert the Grid connector into the Grid port on the bottom of the inverter.

LIVOLTEK Hyper-5000 All-In-One Energy Storage System g1

VIII                     Emergency Load Connection (Backup)

Step 1  Take out the EPS terminal from the package box and unscrew it as below chart.
Step 2  Thread the AC cable of appropriate length through the terminal cap, the sealing ring and the housing.
Step 3  Remove the cable jackets and strip the wire insulation then insert cables into connection terminals according to polarities indicates on it and tighten the screws.
Step 4  Push threaded sleeve onto the connection terminal until both are locked tightly. Then screw up the terminal cap.
Step 5  Insert the EPS connector into the EPS port on the bottom of the inverter. Connect the other ends to the backup loads.

LIVOLTEK Hyper-5000 All-In-One Energy Storage System h1

IX                     COM(Meter/CT) Connection

A: Smart Meter (optional)+ CT Connection

LIVOLTEK Hyper-5000 All-In-One Energy Storage System i1

  1. RS485
  2. Smart Meter
  3. Grid
  4. Arrow point to inverter
  5. Load

LIVOLTEK Hyper-5000 All-In-One Energy Storage System i2

  1. From Grid
  2. To Inverter/Load

LIVOLTEK Hyper-5000 All-In-One Energy Storage System i3

Smart Meter Pin Define

PIN

1 2
Definition 485B

485A

B: CT Connection

CT cable is 5m as default,
could be extended to max 100m,
and must use communication cable (CAT 5 or CAT 5E).

LIVOLTEK Hyper-5000 All-In-One Energy Storage System i9

a) conductor
b) Public grid side
c) Inverter side
d) Arrow point to inverter

CT Cable Pin Definition

PIN

3 4
Definition CT+(Red)

CT-(White)

X                     Battery Connection

LIVOLTEK Hyper-5000 All-In-One Energy Storage System i4

LIVOLTEK Li-ion battery

  1. Communication connection
  2. Power connection

A: Battery power cables connection

Skip this step if you are using LIVOLTEK Li-ion batteries.
The power cables is prepared in battery accessory box.

LIVOLTEK Hyper-5000 All-In-One Energy Storage System i5

Step1  (Optional) Assemble the battery cable Connectors.
Step2  Insert battery connectors to BAT port on the inverter.
Step3  Connect the other side of Battery cables to the Battery.

LIVOLTEK Hyper-5000 All-In-One Energy Storage System i6

B: BMS cable connection

LIVOLTEK Hyper-5000 All-In-One Energy Storage System i7

1.BMS_CAN_H
2.BMS_CAN_H
3.NULL
4.GND
5.NULL
6.NULL
7.NULL
8.NULL

LIVOLTEK Hyper-5000 All-In-One Energy Storage System i8

a) For Li-ion battery communication via CAN protocol.

Step1  Assemble the BMS cable Connector
Step2  Connect the BMS cable to the inverter
Step3  Insert other side of BMS cable into COM port on the battery.
Make sure the Li-Ion battery BMS port connects to the inverter is Pin to Pin.

XI                     Wi-Fi Dongle Connection

Wi-Fi Dongle (Wi-Fi & Bluetooth 2in1 function) establish communication connection to the LIVOLTEK portal server through wireless network to provide local or remote monitoring, data logging and maintenance on the inverter.

LIVOLTEK Hyper-5000 All-In-One Energy Storage System j1

  1. WiFi< 10m
  2. Bluetooth< 5m

Wi-Fi Dongle Connection Steps:
Step 1  Remove the waterproof lid from the Wi-Fi/4G terminal.
Step 2  Insert the Wi-Fi Dongle into the communication port.
Step 3  Build the connection between the Wi-Fi dongle and home WiFi router by our livoltek App local mode.
Refer the App guide manual delivered with the product or find it at our App homepage ‘guide’ (please install ‘My Livoltek’ APP on your phone firstly)

‘My Livoltek’ is a platform to communicate with your device via WiFi or bluetooth, you can login on our web(link as below) on your computer, also you can scan the QR code to download the APP on your phone.

APP: Search for My Livoltek on Apple App Store, Google Play.

WEB LINK1 : https://www.livoltek-portal.com/ For Asia, Latin American, Australia and others
WEB LINK2 : https://evs.livoltek-portal.com/ For Europe, Middle East Regions, Africa

Google Play a1 GW2900D-NS - App Store LIVOLTEK Hyper-5000 All-In-One Energy Storage System j2

LIVOLTEK Hyper-5000 All-In-One Energy Storage System j3        LIVOLTEK Hyper-5000 - QR Code

My Livoltek         Download

XII                     Power ON/OFF the Inverter

(A) Inspection before Commissioning

No. Content State
1 All the switches connected to the inverter are set to the OFF position. Yes No
2 The inverter is installed correctly and securely.
3 All cables are connected correctly and securely.
4 Unused cable holes are fitted using the waterproof nuts.
5 The Wi-Fi  Dongle is installed correctly and securely.
6 The electrical conduit holes are sealed.
7 The CT or smart meter is connected.
8 The battery is well connected.

(B) Powering on the System

Step 1
Turn on the AC breaker on the ON-GRID side.

Step 2
Turn on the battery breaker and Battery.

Step 3
Rotate the DC switch of the inverter to ON position.

Step 4
Turn on the AC breaker on the BACK-UP side.

Step 5
Wi-Fi Dongle connection.

Step 6
Observe the LED indicator.

Note: The shutdown steps are opposite to the above order.

(C) LED Display

LIVOLTEK Hyper-5000 All-In-One Energy Storage System k2

  1. PV
  2. System
  3. Grid
  4. Load
  5. Fault
  6. Battery

Color

Status Description
Green On

The inverter is running normally

Off

Other statuses except Running
Red On

Fault occurs

Off

No fault occurs
Green/Red Blink

System startup or updating

Warning 12 WARNING Before maintaining and commissioning inverter and its peripheral distribution unit switch off all the charged terminals of the inverter, and wait at least 10 minutes after the inverter is powered off.

Documents / Resources

LIVOLTEK Hyper-5000 All-In-One Energy Storage System [pdf] Installation Guide
Hyper-5000 All-In-One Energy Storage System, Hyper-5000, All-In-One Energy Storage System, Energy Storage System, Storage System

References

Leave a comment

Your email address will not be published. Required fields are marked *