TS-R1000 Trunking Digital Repeater
“
Specifications:
- Approved antennas and accessories by TSITS only
- Operating Temperature Range: Consult user manual for
details - Input Power Requirements: AC power socket with built-in
switching power supply - Site grounding and lightning protection required
Product Usage Instructions:
1. Installation Environmental Requirements:
Only use TSITS approved antennas and accessories. Ensure proper
site grounding and lightning protection to prevent damage to the
equipment.
2. Input Power Requirements:
Use the AC power socket with a built-in switching power supply.
Contact the dealer for specific details.
3. Site Grounding and Lightning Protection:
Proper grounding and lightning protection are crucial. Connect
the repeater to field ground using the grounding screw on the rear
of the power module. Ensure correct RF grounding for unwanted RF
energy.
4. Do Not Use the Repeater in the Following Situations:
- Avoid using near explosive sites, on airplanes, and near gas
stations.
Frequently Asked Questions (FAQ):
Q: Can I use any antennas with the repeater?
A: No, only TSITS approved antennas should be used with the
repeater to ensure proper functionality.
Q: What is the recommended temperature range for operating the
equipment?
A: Consult the user manual for specific details on the operating
temperature range.
Q: How do I connect the repeater to field ground?
A: Utilize the grounding screw located on the rear of the
repeater power module to connect it to field ground for proper
grounding.
“`
Important matters
Please read this instruction manual carefully before use. Please keep this manual, which contains important instructions for the use of TS-R1000. § Please consult the dealer about the operation of cluster mode, IP interconnection mode and transit mode.
! Installation Environmental Requirements.
Only TSITS approved antennas and accessories can be installed. Operating Temperature Range
-30 ° C (- 22 ° F) to+60 ° C (+140 ° F). This temperature is the temperature measured in the vicinity of the repeater. For example, if the repeater is installed in a cabinet, the temperature is the temperature measured inside the cabinet. Humidity The relative humidity shall not exceed 95% at 50 ° C (122 ° F).
! Input Power Requirements.
The relay station is equipped with a DC power interface and a standard 3-core AC power interface (optional). DC power interface, the working range of this device is DC 13.8V ± 10%, and the power supply current is not less than 15A. The standard 3-core AC power interface provides a standard 3-core wire to connect the power supply to the AC voltage source. This equipment must be installed next to an easily accessible AC power source. The socket must be connected to an AC power supply capable of providing a maximum power of 280 W. A standard 3-wire grounded receptacle is recommended for connection to AC power.
Note: The power supply mode of the AC power socket provided by the equipment is optional, and the built-in switching power supply is required. For details, please consult the dealer
! Site grounding and lightning protection.
Proper site grounding and lightning protection are important matters that must be considered. Failure to provide proper lightning protection
can cause permanent damage to the intercom equipment.
Providing adequate lightning protection is essential to ensure a safe and reliable communications site. RF transmitter cables as well as AC and DC must be protected Power cords to prevent lightning strikes when lightning enters the site.
The repeater is equipped with a grounding screw located on the rear of the repeater power module. This screw is used to connect the repeater to field ground.
Correct RF grounding. This type of grounding involves the grounding of unwanted RF energy. An example of RF grounding is the use of shielding to protect against interference from communications equipment and cable for harmful RF energy or to minimize this emission.
! Do not use the repeater in the following situations.
Near explosive sites. On the airplane. Near the gas station.
Catalog
1 Panel Description ………………………………………………………………………………………………2
Panel Description
……………………………………………………………………………………2
Indicator lights5
Buttons5
Volume knob6
the annex interface
……………………………………………………………………………………6
2 Basic Operations
…………………………………………………………………………………………7
power on and off
…………………………………………………………………………7
Channel selection
…………………………………………………………………………7
Volume adjustment
…………………………………………………………………………………7
Listen mode enable
……………………………………………………………………………7
PTT allow call
…………………………………………………………………………………………7
PTT call
………………………………………………………………………………………7
3 equipment installation
………………………………………………………………………………………………8
mechanical installation
………………………………………………………………………………………8
electrical connections
………………………………………………………………………………………8
Installed and inspected
………………………………………………………………………………………………9
equipment accessories
……………………………………………………………………………………10
Cleaning
……………………………………………………………………………………………10
Panel Description
12
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
1 Panel
19
– 2 –
1 Panel
Serial number 1 2
3
4 5 6 7 8 9 10
11 12 13 14 15
The name of the part
Description
With this position, it can be fixedly mounted in a standard Locate mounting holes that
chassis.
Carrying Hand
the annex interface
1. Connect the microphone accessories, through the microphone to realize the repeater active call other devices. 2. Connect the data cable attachment for repeater data information setting/reading and monitoring.
LED indicator
digital tube display area
Pushbutton
Volume knob
Horns
Fixed support feet
Receiving antenna interface
Ethernet port
Type N
10-Base-T/100-Base-Tx (RJ45) When IP board accessories are selected, this interface is open.
USB interface
Open this interface when IP board accessories are selected
Extended interface
including programming and audio interfaces
Transmitter Antenna Interface
Type N
DC power fuse
When using DC power supply, use this fuse
– 3 –
1 Panel
16 17 18 19
DC power jack AC power socket Grounding post Heat sinks
13.8V AC-220V enclosure grounding
– 4 –
1 Panel
Indicator light
Serial number
Icons
1
PWR
2
MOED
3
TX
4
RX
Pushbutton
Serial number
Icons
Name Power status
indicator Mode indicator
Launch Indicator
Receiving indicator
Description 1. The left side is red, the power supply turns on and lights up 2. The right side is yellow and goes out when there is a warning 1. The left side is blue, and the digital mode lights up 2. The right side is white, and the analog mode is on 1. The left side is red and lights up when transmitting (slot 1 is indicated in TM mode) 2. The right side is red and lights up when transmitting (slot 2 is indicated in TM mode) 1. The left side is green and lights up when receiving (slot 1 is indicated in TM mode) 2. The right side is green and lights up when receiving (slot 2 is indicated in TM mode)
Description
Serial number
Icons
Description
1
Channel switching
4
P1
Customizing the keys
2
Channel switching
5
P2
Customizing the keys
– 5 –
1 Panel
3
Power button
6
P3
Customizing the keys
Volume knob
details.
The volume knob is located on the right side of the panel. Rotate clockwise to turn up the volume. Turn counterclockwise to reduce the volume.
Note: The repeater will only play sound when the listening function is turned on. This function needs to be configured through the configuration interface, please ask your dealer for
the annex interface
other devices.
The accessory port is located on the left side of the panel and supports the following functions. 1. Connect the microphone accessories, through the microphone to realize the repeater active call
2. Connect the data cable attachment for repeater data information setting/reading and monitoring.
– 6 –
1 Panel
Attention: when using the change of interface accessories, you need to choose the fittings in line with our company’s standard products.
to the equipment
Use of products that do not comply with our accessories may result in damage to the interface or damage
– 7 –
2
Basic
power on and off
Power on: Connect the repeater to the external power supply, the repeater will turn on automatically; long press the power button in the off state, the repeater will turn on.
Shutdown: In power-on state, long press the power button, the repeater will shutdown.
Note:The listening function needs to be turned on
Listen mode enable
This feature is enabled through the configuration software.
Channel selection
The digital tube displays the current channel number. Press the channel switching button or Switching channels.
PTT allow call
This feature is enabled through the configuration software.
Volume adjustment
Turn the volume knob to turn up the sound clockwise and turn down the time counterclockwise.
PTT call
Connect the microphone attachment. [PTT Allow Call] enable. Press and hold PTT, the red light of the emission indicator lights up,
and you can speak at 5-10cm from the microphone.
– 8 –
2
Basic
Release PTT and the call ends.
– 9 –
3 equipment
mechanical installation
This section describes the steps of unpacking and mechanical installation of TSITS repeater. The installation method can be changed according to the type of cabinet or rack selected to fix the repeater.
! If the module must be removed from the repeater, be sure to
observe proper ESD precautions. unpacking equipment
The box contains the following items. TSITS repeater DC power cord (optional DC version) AC power cord (optional AC version) Microphone and microphone holder (optional accessory) Data cable (optional accessory) Operation Manual of TSITS Trunk Station installing the equipment into the cabinet The repeater can be mounted in a rack or cabinet.
! The cabinet and rack provided by the user must be equipped
The two mounting rails are 5 cm (2 in.) from the front of the cabinet, with the front mounting holes spaced (2.25 in.) apart (center to center).
For detailed questions about installing equipment in the cabinet provided by the user, please contact TSITS technical support department.
electrical connections
Electrical connection must be carried out after the mechanical installation of TSITS repeater. The connection includes the following:
DC power cord (or AC power cord) Antenna coaxial cable. AC input power connection
! Do not supply AC power to the repeater at this time. Ensure
that the circuit breaker connecting the associated AC outlet is disconnected.
! The AC power supply must be mounted near the equipment and
with rails and hole spacing, meet the EIA general 48.3 cm (19
easily accessible.
inches) specification, and must meet the following minimum
Each repeater comes with a 3-prong power cord to connect the
standards: Depth of 41.3 cm (16.25 inches)
repeater to 110~240 AC power. Insert the 3-prong plug into the [AC power connector]. If an antenna wire is required, purchase a
Width 48.3 cm (19 inches)
suitable wire from a qualified electrical parts supplier with a
Height 13.4 cm (5.25 inches) – 10 –
3 equipment
connector that has been approved by an end-use national safety testing organization. DC input power connection
! Do not supply power to the repeater at this time. Ensure
that you check that the positive and negative connections of the power cord are correct before supplying power grounding connections
The repeater is equipped with a grounding screw, located on the back of the repeater. Connect the field ground cable to the ground screw. duplexer selection
The choice of duplexer is very important for the performance of the system. Some systems not used in high RF density locations may use notch (band filter) diplexers. The duplexer must be able to work continuously at least 50 W. For optimum system performance, the insertion loss should be less than 2 dB. If the repeater is used in a high RF density area, it is recommended to use a band-pass band stop duplexer. RF antenna connection
Two independent interfaces are used to connect the transmitting and receiving RF antennas. Coaxial cables of receiving and transmitting antennas must be connected to N-type (Tx) and N (Rx) interfaces. In order to use a repeater, there must be sufficient isolation between antennas, or if an antenna is used, the duplexer must have sufficient isolation between Tx and Rx ports.
The insulation requirements of each frequency band are different,
as shown in the following table:
Frequency
Bandwidth
Isolation
points
UHF 1
403470 MHz
75dB
UHF 2
450520 MHz
85dB
UHF 3
350390 MHz
75dB
VHF
136174 MHz
antenna selection
85dB
Antenna selection is critical to the performance of the system.
An antenna with an impedance of 50 ohms and a capacity of at least
50 watts must be selected. A gain antenna can be used to increase
system coverage. Be aware of the limitations when selecting a gain
antenna. Some services and areas may have antenna gain or radio
management restrictions. A 50-ohm premium transmission line
(hardwire) must be used to connect the antenna to the duplexer.
The line must be equipped with connectors that match those on the
duplexer and antenna.
! It is very important that all antennas be grounded at the
point where they are introduced into the building.
! Antenna design is the responsibility of the user. All aspects
of antenna design must comply with relevant local regulations.
– 11 –
3 equipment
post-installation inspection
After completing the mechanical installation and all electrical connections of the TSITS repeater station, power on and check whether the repeater operates normally. energized
Before powering up the repeater, make sure that all boards are secured in their respective ports on the baseboard and that all RF cables are securely connected.
Turn on the power supply to the repeater power module. Checking for proper functioning
The operation of the transponder can be checked by the following steps. Observe the display lamp status on the LCD display. Operate walkie-talkie call experiments.
! During operation, some transponder components may become
very hot. Turn off all power to the transponder and wait until it has cooled completely before touching it.
– 12 –
3 equipment
equipment accessories
as detergents, alcohol, sprays, or petroleum-based agents to avoid damage to the surface and housing. After cleaning, make sure the product is thoroughly dry, otherwise do not use it.
Serial number
1 2 3 4
5
6
Project
Quantity
Repeater Instruction manual AC power cord (optional) DC power cord (optional) Hand microphone and mounting bracket (optional accessory) Data cable (optional)
1 part 1 copy 1 root 1 root
1 set
1 root
Cleaning
Use a clean, dry, lint-free cloth or brush to wipe away dust on the surface of the product and the charging pole piece on a regular basis.
The buttons, control knobs and housing of this product are very susceptible to soiling. They can be cleaned with a neutral detergent and a non-woven cloth. Do not use chemicals such
FCC Caution:
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
–Reorient or relocate the receiving antenna. – 13 –
3 equipment
–Increase the separation between the equipment and receiver. –Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected. –Consult the dealer or an experienced radio/TV technician for help.
During transmissions, your radio generates RF energy that can possibly cause interference with other devices or systems. To avoid such interference, turn off the radio in areas where signs are posted to do so. DO NOT operate the transmitter in areas that are sensitive to electromagnetic radiation such as hospitals, aircraft, and blasting sites.
This radio is designed for and classified as Occupational/Controlled Use Only, meaning it must be used only during the course of employment by individuals aware of the hazards, and the ways to minimize such hazards; NOT intended for use in an General population/uncontrolled environment
DO NOT operate the radio without a proper antenna attached, as this may damage the radio and may also cause you to exceed RF exposure limits. A proper antenna is the antenna supplied with this radio by the manufacturer or an antenna specifically authorized by the manufacturer for use with this radio, and the antenna gain shall not exceed 3.5dBi by the manufacturer declared.
DO NOT transmit for more than 50% of total radio use time, more than 50% of the time can cause RF exposure compliance requirements to be exceeded.
During operation, the separation distance between user and the antenna shall be at least 89cm, this separation distance will ensure that there is sufficient distance from a properly installed externally-mounted antenna to satisfy the RF exposure requirements – 14 –
Documents / Resources
![]() |
Lisheng TS-R1000 Trunking Digital Repeater [pdf] Instruction Manual R1000, 2BBCYR1000, TS-R1000 Trunking Digital Repeater, TS-R1000, Trunking Digital Repeater, Digital Repeater, Repeater |