LINORTEK Netbell-4-4Buz Network Break Buzzer System
Package Contents Checklist
- Netbell-4K Server (01-910-00035) (1)
- Buzzer Kit (01-910-00040) (4)
- RJ45 Cable (01-390-00028) (1)
- Power Cable (01-850-00029) (1)
- Bell Cables (01-850-00046) (4)
- 12VAC Power Supply (01-850-00022) (1)
- Wago Connector (01-350-00129) (4)
- 1 Set of Mounting Brackets (1)
- Netbell Setting Instructions
- This Installation Guide
Installation Steps
Step 1: Mounting the Netbell-4 Controller
- Choose a dry, indoor location for installation
- Using the provided mounting brackets:
- Attach mounting brackets to the SERVER using provided self-tapping screws (4 places)
- Install the SERVER at desired location using appropriate screws for your wall type
- Ensure adequate ventilation around the unit
Step 2:
Buzzer Wiring Instructions
Relay Output Specifications:
- Four relay outputs for controlling timed signal equipment, labeled as EXT1 to EXT-4
- Dry Contact type (1-Form-A relay)
- Maximum rating: 48VAC @ 8A per relay
- Normally Open (NO) contacts, convertible to NC if needed
Buzzer Wiring Steps:
- Buzzer Mounting and Cable Requirements:
- Mount the pre-wired buzzer kit at the location you would like to have your buzzer
- You can extend the power cable of the buzzer if needed
- Buzzer can be installed at 500 feet away from controller using 16AWG cable
- Basic Connection Setup: the relays on the Netbell-4 K are dry contact relay with CP connector and four bell cables (3FT) come with your Netbell-4K.
- Connect CP connector side of bell cable to one of the bell outputs (EXT1 to EXT4)
- Connect one power source wire to one side of the buzzer
- Connect other power wire to one side of the bell cable
- Connect remaining buzzer wire to other side of bell cable
- Repeat wiring process for all four buzzers
Standard Bell Buzzer Wiring
(Normally Open Configuration)
IMPORTANT: Total current draw of all connected bells/buzzers must not exceed 8A
Multiple Buzzer Configuration:
- Each relay can control devices up to 8A total current
- Total current draw of all connected buzzers must not exceed 8A
- Ensure power supply rating matches total buzzer current requirements
- Verify total current draw is within specifications before operation
Multiple Bells/Buzzers Wiring
(Parallel Configuration)
Important:
- Total current draw of all connected buzzers must not exceed 8A
- Ensure power supply rating matches total buzzer current requirements
IMPORTANT NOTES:
- This device is NOT designed to directly switch line voltage (120V/240V)
- For line voltage devices, an intermediary relay MUST be installed
- Verify all connections before applying power
- You can install the buzzer at up to 500 ft away from the controller using 16 AWG 2-conductor wire
- Use appropriate wire gauge for current rating
Step 3:
Digital Input Connections (Optional)
The Netbell-4 features one digital input (DIN 1) that can detect external on/off states of sensors. The most common use of the digital inputs for the Netbell is to connect a push button switch to activate the bell manually for emergency.
- Connect the push button to the digital input connector (DIN 1)
- Open the device enclosure carefully.
- Position the device so the connector side faces you.
- Locate the digital input switches (labeled DIN1 and DIN2) in the lower left corner near the Ethernet connector.
- Make sure the digital input switches are at the UP position to enable PU (Pull-Up) mode.
- Configure the software
Step 4:
Network Connection
- Plug RJ45 cable into NET connector
- Connect to router or network switch
IMPORTANT NOTE:
- Netbell-4K board requires 1000Mbps (Gigabit) port/switch
- Will not work on 10/100Mbps port/switch
- Verify switch compatibility with IT department
Step 5:
Power Connection
- Connect power cable to 12VAC power supply terminals
- Plug power supply into suitable AC outlet
- Connect power cable CP connector to Server’s POWER port
WARNING: Use only provided power adapter from Linortek
Safety Warnings
- Indoor use only – NOT FOR OUTDOOR USE
- Avoid high humidity environments
- Keep away from water and liquids
- No explosive environments
- Do not use during thunderstorms
- Never remove power during firmware updates (when RED LED blinks and GREEN LED is on)
- Use only Linortek-provided power adapter
- Avoid cable damage from mechanical pressure
- Route cables to prevent tripping hazards Troubleshooting Guide
No Power
- Check power connections
- Test with alternate power method
No Network Connection
- Verify cable connections
- Check network switch status
- Make sure the network port/switch is 1000Mbps (Gigabit)
- Confirm LED indicators
- Green LED light is flashing, orange LED is solid (To check the LED indicators, you need to open the enclosure)
Bell Not Working
- Verify wiring connections, check contact connection. If you use the Wago connector we provide:
- Lift the lever completely to fully open position
- Strip wire to 11mm length
- Insert wire fully into the connector opening
- Push lever down completely until it clicks
- Verify lever is fully closed and flush with connector body
- Gently pull each wire to confirm secure connection
- Check power supply ratings
- Confirm load is within power supply limit if multiple buzzers are used
Safety Warnings
- Indoor use only
- Avoid high humidity
- Keep away from water
- No explosive environments
- Do not disconnect power during firmware updates (when RED LED blinks and GREEN LED is on)
Resources & Technical Support
For complete documentation and instructions:
- Visit: https://bit.ly/01-910-00119 , navigate to Manuals & Resources tab
- Or scan QR code from your mobile device to access the documents from the item page:
- Email support: support@linortek.com
Linor Technology, Inc.
Information subject to change without notice. www.linortek.com
FAQ
- Q: What should I do if there is no power?
A: Check power connections and test with an alternate power method. - Q: What should I do if there is no network connection?
A: Verify cable connections, check network switch status, and ensure the network port/switch is 1000Mbps.
Documents / Resources
![]() |
LINORTEK Netbell-4-4Buz Network Break Buzzer System [pdf] Instructions Netbell-4, Netbell-4Buz, Netbell-4-4Buz Network Break Buzzer System, Netbell-4-4Buz, Network Break Buzzer System, Break Buzzer System, Buzzer System |