Lindab CBC Plenum Box Installation Guide
Lindab CBC Plenum Box Installation Guide

Symbols

  • Supply air
    symbols
  • Extract air
    Symbols
  • Open damper
    Symbols
  • Closed damper
    Symbols
  • No tools – Magnet
    Symbols
  • Lock
    Symbols
  • Unlock
    Symbols

Unpacking and protection of CBC/CBE
Unpacking and protection

Accessories

  • MHS
    Accessories
  • M8
    Accessories
  • PC410
    Accessories

Dimensions
Dimensions

Ød1       Ød2 mm B C D emm H L W mkg
100 125 65 213 78 40 175 273 209 1.4
100 160 65 231 78 40 175 308 244 1.6
125 160 78 250 78 40 200 327 244 1.9
125 200 78 270 78 40 200 367 284 2.3
160 200 95 295 78 40 234 392 284 2.6
160 250 95 320 78 40 234 442 334 3.1
200 250 115 345 78 40 274 467 334 3.6
200 315 115 377 78 40 274 532 399 4.3
250 315 140 423 118 60 325 558 399 6.5
250 400 140 466 118 60 325 643 484 8.6
315 400 173 536 118 60 390 714 484 9.8

Damper options
Damper options
Damper options Damper options

Mounting of CBC/CBE
Accessory MHS
Threaded rod M8
Mounting of CBC/CBE

Directly against ceiling
Directly against ceiling

Mounting of diffuser in CBC/CBE

Mounting of diffuse

Diffusers: PKA, PCA, LKA, LCA, LCC, LCP, LKP, NO19

Use self tapping screws Not included

Balancing
Balancing
Balancing

k-factors for ceiling diffusers + CBC

Supply air

CBC
Supply air
 PCA  PKA FormoLCA  LKA Integra LCC/LCP       LKP  NQ19
SUPPLY
CBC-100-125 9.92 9.80 9.37 9.19 8.64 8.18
CBC-100-160 11.64 11.87 10.87 11.44 10.75 10.65 11.06
CBC-125-160 14.66 14.82 12.88 13.78 12.77 12.32 10.94
CBC-125-200 16.96 18.09 14.58 17.06 15.71 15.19 17.82
CBC-160-200 21.39 22.90 17.32 20.65 18.26 17.31 17.57
CBC-160-250 25.98 25.83 22.85 24.19 20.63 21.58 23.38
CBC-200-250 30.91 30.33 26.29 28.23 23.44 24.60 25.17
CBC-200-315 42.64 43.58 33.31 36.78 28.17 29.48 32.24
CBC-250-315 43.04 43.50 32.23 35.99 27.66 28.60 36.90
CBC-250-400 55.65 55.44 35.25 41.35 41.78
CBC-315-400 62.89 70.18 35.72 43.74 44.33
Supply
Diffuser Straight duct
SR
Straight duct
Bend
BKU, BU, BSU
Bend
Expansion
RCFU
T-piece + min. 2xD*
TCPU
Expansion
LCC / LCP / LKP / NQ19 ±5 ±7,5% ±7,5% ±10,0%
LCA / LKA 15 47.5% $7.5% 10.0%
PCA/PKA 7.5 10.0% 10.0% 12.5%

To fulfill the above-mentioned accuracy levels, the min. air speed at the diffuser connection ( Ød2  ) of the plenum box should be 1.2 m/s,  which corresponds to the following min. air flow for different sizes

Diffuser connection Ød2 min. Air flow
mm l/s
125 15
160 24
200 38
250 59
315 94
400 151
To fulfill accuracy for T-piece the following limitations are to be considered.
Between T-piece and plenum box it is recommended to have 2xD straight duct, ( where D is the duct connection diameter Ød1 ) .
Furthermore, the air speed in main duct should not exceed 6 m/s.
T-piece limitation

k-factors for ceiling diffusers + CBE

Extract air

CBE
Extract air
 PCA FormoPKA           LCA  LKA Integra LCC/LCP                       LKP
EXTRACT
CBE-100-125 27.27 25.38 16.86 16.08 15.83 16.05
CBE-100-160 30.54 45.55 26.52 20.74 20.84 21.03
CBE-125-160 23.68 30.45 20.45 17.99 18.58 20.44
CBE-125-200 42.66 51.88 27.70 27.52 18.39 25.90
CBE-160-200 33.16 33.80 25.23 26.66 19.98 21.85
CBE-160-250 40.15 59.99 34.07 40.18 22.15 25.65
CBE-200-250 42.32 44.98 31.05 35.54 23.58 26.28
CBE-200-315 73.24 83.27 45.47 53.07 29.64 28.99
CBE-250-315 57.35 59.56 38.27 43.60 22.99 28.20
CBE-250-400 114.1 132.61 41.62 47.57
CBE-315-400 104.11 103.77 40.27 48.54
Extract
Diffuser All connections
LCC / LCP / LKP ±5%
LCA / LKA ±5%
PCA / PKA ±7.5%

To fulfill the above-mentioned accuracy levels, the min. air speed at the diffuser connection ( Ød2 ) of the plenum box should be 1.2 m/s,   which corresponds to the following min. air flow for different sizes:

Diffuser connection Ød2 min. Air flow
mm l/s
125 15
160 24
200 38
250 59
315 94
400 151

Maintenance
MaintenanceMaintenance

Store the damper in the plenum box

Installation of C- and E-damper
Installation
Installation

For balancing pull measuring tube and damper strings out of plenum box before clicking on faceplate. When balancing, diffuser faceplate MUST be on ! After balancing store strings in box and lock damper strings, see page 7.
Most of us spend the majority of our time indoors. Indoor climate is crucial to how we feel, how productive we are and if we stay healthy.
We at Lindab have therefore made it our most important objective to contribute to an indoor climate that improves people’s lives. We do this by developing energy-efficient ventilation solutions and durable building products. We also aim to contribute to a better climate for our planet by working in a way that is sustainable for both people and the environment.
office
Office
Lindab Logo

Documents / Resources

Lindab CBC Plenum Box [pdf] Installation Guide
CBC, CBE, CBC Plenum Box, CBC, Plenum Box, Box

References

Leave a comment

Your email address will not be published. Required fields are marked *