The LetPot ECT-P EC meter is designed for hydroponics and water testing. Use the EC button to control the water pump (on pump versions), switch temperature units, measure EC/temperature, and perform calibration and network setup via on-device prompts.

Specifications

Product EC Meter for hydroponics and water testing
Model ECT-P
Version ECT02-White
Power USB cable + Type-C power cable (device powers on automatically)
Wi‑Fi support Only 2.4 GHz Wi‑Fi networks
Water pump work/rest cycle 30 min work / 30 min rest (automatic)
Probe/measurement notes Probe should be submerged in water for accurate detection

Quick Setup & Use

  1. Connect the USB cable and the Type-C power cable to the EC meter. The device powers on automatically.
  2. Insert the probe into one of the pods in your hydroponic system.
  3. Press and hold the EC button for 3 seconds to activate the device (data collection begins after powering on).
  4. If you have the pump version, connect the pump cable during Step 1 (the pump cable can be routed through the pod).
  5. To measure, tap the EC button. To measure EC and temperature, use the EC button (per on-device instructions).
  6. Tap to switch temperature units. Press and hold the EC button for network settings (follow the prompts) if needed.

ECT Button Instructions

LetPot-ECT-P-EC-Meter-ECT02-FIGURE-1.

  • Water Pump Icon:
    • Green: On
    • Gray: Off
    • Rotating: Working
    • Stationary: Resting
    • PS: 30 min work/rest cycle automatically
  • EC Value Colors:
    • Green: Normal
    • Red: Too high
    • Blue: Too low
  • Temp
    • Green: Normal
    • Red: Too high
    • Blue: Too low
  • Tap:
    Switch temperature unit.
  • Press and hold:
    Enter network settings; follow prompts to reset and configure.
  • Tap:
    Turn on/off water pump.
  • Press and hold:
    Enter zero baseline calibration; follow prompts to complete.
  • Tap:
    Measure EC and temperature.
  • Press and hold:
    Restart and activate sensor.

How to Set Up

  • Step 1. Connect the USB cable and Type-C power cable to the EC meter. The device will power on automatically.

LetPot-ECT-P-EC-Meter-ECT02-FIGURE-2

  • Step 2. Insert the probe into one of the pods in your hydroponic system. Then, press and hold the “EC” button for 3 seconds to activate the device. The meter will begin collecting data as soon as it is powered on.

LetPot-ECT-P-EC-Meter-ECT02-FIGURE-3.

  • Step 3. If you have the pump version, connect the pump cable during Step 1. For easier cable organization, you can use the same pod where the probe is placed and carefully thread the pump cable through the pod.

LetPot-ECT-P-EC-Meter-ECT02-FIGURE-4

Basket Structure

The ECT is specifically designed for desktop hydroponic systems and has a universal basket shape. You can also remove the basket for use, but please ensure the probe is submerged in water to ensure accurate detection. If you want to put the probe back in the basket, just push it all the way down and give the lid a twist to lock it in place.

Documents / Resources

PDF thumbnailECT-P EC Meter (ECT02-White version)
User Manual · LetPot, ECT02-White, ECT-P, EC meter

References

Ask a Question

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Ask a Question

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.