BDA Central Control Panel
Product Information
Specifications
- Frequency: Not specified
- RFID Technology: L1LA13MX
- Energy Supply: Not specified
- Operating Temperature: Not specified
- Storage Temperature: Not specified
- Type Designation of RFID Reader: L1LA13MX
Product Usage Instructions
1. Safety Precautions
Before operating the Central Control Panel, ensure that you have
read and understood all safety precautions mentioned in the user
manual.
2. Care and Maintenance
Regularly clean the Central Control Panel using a soft, dry
cloth to prevent dust accumulation. Avoid using harsh chemicals or
solvents.
3. Mounting Instructions
To mount the Central Control Panel flat/open frame, follow these
steps:
- Choose a suitable location for mounting.
- Securely fix the panel using appropriate screws or mounting
brackets. - Ensure the panel is level and securely attached to the
surface.
4. Commissioning
Follow the steps outlined in the user manual to commission the
Central Control Panel for operation. This includes setting up the
admin area and changing the PIN code.
5. Admin Area Setup
In the Admin area, configure settings for online and offline
operation modes. Change the default PIN code to enhance
security.
Frequently Asked Questions (FAQ)
Q: Can the Central Control Panel be used with steel doors?
A: The terminal is not suitable for steel doors due to the
standard internal mounting of the RFID reader.
Q: Where can I find more information on changing the factory
PIN code?
A: Detailed instructions on changing the factory PIN code can be
found in the Admin area chapter of the user manual.
www.lehmann-locks.com
GB
BDA CENTRAL CONTROL PANEL flat / open frame / 2025-08-19 (GB)
Central Control Panel
flat / open frame
Operating Instructions
CONTENT
PAGE
1. General Description …………………………………………………………………………………………….3
2. Technical Specifications ………………………………………………………………………………………..3
3. Safety Precautions ……………………………………………………………………………………………….4
4. Care and Maintenance …………………………………………………………………………………………4
5. Factory settings …………………………………………………………………………………………………..4
6. Functional Description………………………………………………………………………………………….5
7. System Components and Package Content …………………………………………………………….6
8. Dimensions …………………………………………………………………………………………………………6
9. Mounting the Central Control Panel flat / open frame …………………………………………….7
10. Commissioning…………………………………………………………………………………………………….9
11. Admin area………………………………………………………………………………………………………..11 11.1 Admin area for online operating mode …………………………………………………………11 11.2 Admin area for offline operation mode…………………………………………………………12 11.3 Change PIN code for the admin area…………………………………………………………….12
12. Application: LMS Online Self Service ……………………………………………………………………13 12.1 Lock configuration in the LEHMANN Management Software LMS…………………….13 12.2 General Operation……………………………………………………………………………………..13 12.3 Add locker…………………………………………………………………………………………………14 12.4 Open locker ………………………………………………………………………………………………15 12.5 Manage locker…………………………………………………………………………………………..15 12.6 Emergency opening……………………………………………………………………………………15 12.7 Release of a locker by the admin………………………………………………………………….15
13. Application: LMS Virtual Network………………………………………………………………………..16 13.1 Lock configuration in the LEHMANN Management Software LMS ……………………16 13.2 Transfer of permissions to transponders……………………………………………………….16
14. Application: Locker info………………………………………………………………………………………18
15. Application: Pick-Up …………………………………………………………………………………………..18 15.1 Programming transponders and email addresses …………………………………………..18 15.2 Configuring the mail server settings……………………………………………………………..18 15.3 Configuring the Pick-up application in the LMS………………………………………………18 15.4 Operating the terminal with the Pick-up application ……………………………………..18 15.4.1 Deposit a package …………………………………………………………………………..18 15.4.2 Pick up the package …………………………………………………………………………18
16. Disposal…………………………………………………………………………………………………………….19
BDA CENTRAL CONTROL PANEL flat / open frame / 2025-08-19 (GB)
2
1. GENERAL DESCRIPTION
The Central Control Panel is an interactive terminal that is used to operate LEHMANN RFID locks. The product is intended for use in office areas inside buildings. These operating instructions provide you with information on how to operate this product without errors. Keep the operating instructions in an easily accessible place. Improper use can destroy the this product and lead to the loss of any warranty claims. Note that the Central Control Panel consists of the ELO Touchscreen, an ELO Backpack PC and a LEHMANN RFID reader. Information about the ELO terminal can be found in the separate ELO Quick Installation Guide, which is included with the product, and in the operating instructions, which can be found at www.elotouch.com/support. Please be sure to observe all warnings and read the operating instructions completely before proceeding with installation, commissioning and operation. It may be possible to use this product together with products made by other manufacturers, but their compatibility must be checked in each individual case. We cannot accept any liability for damage or loss due to incompatibility. Wording and graphics have been prepared with care. However, no liability will be assumed for any mistakes that mayhave occurred. Technical specifications as well as the scope of items in the system are subject to change without notice.
ATTENTION: Please change the factory PIN code for the admin area immediately after putting the terminal into
operation. Further information can be found in the “Admin area” chapter.
2. TECHNICAL SPECIFICATIONS
The technical specifications of the terminal can be found in the ELO operating instructions for the I-Series 4.0 Android.
The technical specifications for the RFID reader are as follows:
Frequency
RFID technology Energy supply Operating temperature Storage temperature Type designation of RFID-Leser
13.56 MHz National legislation about permissible radio frequencies must be observed. MIFARE DESFire, LEGIC advant via ELO I-Serie 4.0 Android terminal -5°C to +60°C -25°C to +70°C
L1LA13MX
Due to the standard internal mounting of the RFID reader, the terminal is not suitable for steel doors.
BDA CENTRAL CONTROL PANEL flat / open frame / 2025-08-19 (GB)
3
! 3. SAFETY PRECAUTIONS
Touching parts can lead to injuries from electric shock. Electrical components must not be opened. Do not touch connection terminals when the product is powered. The installation, commissioning and maintenance of our devices must be carried out by appropriately qualified
personnel. In particular, electrical connections may only be carried out by qualified personnel. The installation regulations in accordance with the relevant national regulations must be observed. Unless otherwise specified, the installation and maintenance of the devices must only be carried out in a voltage-free state. This applies in particular to devices that are connected to the low-voltage network.
4. CARE AND MAINTENANCE
Do not spill any liquid over or into the product Only clean the product with a clean, soft and slightly damp cloth. Do not use any cleaning agents containing abrasives or solvents, as these may damage the housing. Treating any of the electronic and mechanical components improperly or in a any way other than described in
these operating instructions may lead to malfunctions and the loss of warranty.
5. FACTORY SETTINGS
The Central Control Panel is delivered with different LEHMANN applications. The software starts automatically. When commissioning, you select an application.
4
BDA CENTRAL CONTROL PANEL flat / open frame / 2025-08-19 (GB)
6. FUNCTIONAL DESCRIPTION
The following applications are available:
Application LMS Online Self Service
LMS Virtual Network
Locker info Pick-Up
Description
This application can only be used when using networked LEHMANN RFID locks (CAPTOS) with the LEHMANN Management Software LMS (LMS Online). In this application, users have the opportunity to select, manage and open available lockers on the central control panel. In addition to RFID transponders, PIN codes are also supported on the terminal for operating the locks. For this application, the Central Control Panel must be connected to the LEHMANN Management Software LMS via the network (LAN or WLAN). Depending on the lock type, the lock can be opened with an RFID transponder on the terminal and/or directly on the lock.
This application can be used with offline LEHMANN RFID locks that are managed in the LEHMANN Management Software LMS. While the Central Control Panel is connected to the LMS directly via the network (LAN or WLAN), the locks are not directly connected to the LMS via the network. Permission changes are sent from the LMS to the terminal. The permissions are updated on the transponders when users hold the transponders in front of the RFID reader of the terminal. The Virtual Network feature is not supported if only the UID of a transponder is processed.
In this application, the number or the name of the previously occupied locker is shown on the terminal display when the transponder is held in front of the RFID reader on the terminal. This application is suitable for both online and offline LEHMANN RFID locks in the “shared use” operating mode. The locks must be managed with the LEHMANN Management Software LMS. The LEHMANN transponder app is currently not supported. The Central Control Panel does not have to be connected to the LMS.
With the LEHMANN Central Control Panel, the LEHMANN Management Software LMS and the networked CAPTOS locks, internal parcel and goods distribution can be handled efficiently. An authorized employee stores a package in a locker, the recipient is automatically notified and can pick up the package at any time in the respective locker. With a one-time collection code or a QR-code, which is sent directly to the recipient, or with the employee ID card, the package can only be picked up by the recipient. A connection to the customer`s email server is required and must be implemented by the customer.
The prerequisite for using the Central Control Panel is that the LEHMANN RFID locks and the transponders are configured and managed with the LEHMANN Management Software LMS. The licence key for LMS Online is required. The LMS requires version 2.3 or higher. The RFID locks or RFID readers require firmware version 2.3 or higher. The 3D camera for face recognistion is not supported by this type of terminal.
BDA CENTRAL CONTROL PANEL flat / open frame / 2025-08-19 (GB)
5
7. SYSTEM COMPONENTS AND PACKAGE CONTENT
Please note that due to the different materials on which the Central Control Panel can be mounted, no mounting screws are included.
1 2
178,5 130 75 100
BDA CENTRAL CONTROL PANEL flat / open frame / 2025-08-19 (GB)
5
6
7
4
3 8
Components:
1. ELO Display / Central Control Panel flat / open frame 2. ELO Backpack PC I-Series-4.0 3. Power unit 50 W for ELO Display 4. USB 2.0 cabel, USB-A plug to Micro-B
5. RFID reader L043-A01 for internal mounting 6. Backside housing of RFID reader 7. Double-sided adhesive tape for mounting the RFID reader 8. Countersunk screw 3×13 for housing of RFID reader
8. DIMENSIONS
Central Control Panel flat / open frame
255,8
ELO Backpack PC
114
25,4
75 100
All dimensions in mm
6
Central Control Panel flat / open frame
255.8 (EDGE OF TOUCHSCREEN)
2.7 FOAM SEAL (ALL AROUND)
36.9 R 10.9, X4
218 ACTIVE AREA
136.6 ACTIVE AREA
10.9, X2
178.5 (EDGE OF TOUCHSCREEN)
65
175.7
SIDE MOUNT
RFID reader L043-A01 (for internal mounting)
SIDE MOUNT (LEFT AND RIGHT M4 THRED, X2
BDA CENTRAL CONTROL PANEL flat / open frame / 2025-08-19 (GB)
9. MOUNTING THE CENTRAL CONTROL PANEL FLAT / OPEN FRAME
1) To install the terminal flush in the furniture, a suitable cut-out must first be made in the furniture. The dimensions can also be found in the ELO instructions provided.
255.8 (EDGE OF TOUCHSCREEN)
2.7 FOAM SEAL (ALL AROUND)
36.9 R 10.9, X4
218 ACTIVE AREA
136.6 ACTIVE AREA
10.9, X2
178.5 (EDGE OF TOUCHSCREEN)
65
175.7
SIDE MOUNT
SIDE MOUNT (LEFT AND RIGHT) M4 THRED, X2
All dimensions in mm
7
284
206.7 136, X4
BDA CENTRAL CONTROL PANEL flat / open frame / 2025-08-19 (GB)
RECOMMENDED CUSTOMER PANEL CUT-OUT CHOOSE ONE: A = M4 THREADS OR M4 CONCEALED HEAD
THREADED STUDS WITH NUTS B = CLEARENCE HOLES FOR M4 THREADS
R 12.8±0.3, X4
100 A
193.7
120 B
182.2±0.3
100 A 120 B 259.5±0.3
271
CUSTOMER PANEL (NOT INCLUDED) MIN THICKNESS = 3MM MAX THICKNESS = 13MM
If the terminal is to be mounted on stronger materials, spacer threads can be used (see photo).
All dimensions in mm
8
2) Mount the ELO display on the furniture using the brackets as described in the instructions. 3) Connect the ELO display to the ELO backpack PC using an HDMI cable and a USB cable. The USB-B plug is
plugged into the ELO display and the USB-A plug into the ELO backpack PC (except the ADB port!). The PC can optionally be attached to the ELO display. 4) Connect the RFID reader L043-A01 to the ELO backpack PC (not to the ADB port!) using a USB cable ,,USB-A plug to micro USB”. Press the RFID reader and the back of the RFID reader`s housing together and tighten the 3×13 screws by hand. Remove the protective film from the adhesive strip on one side and stick the adhesive strip to the front of the RFID reader (the LED will be covered). Remove the protective film from the adhesive strip on the back and place the RFID reader in the desired location. Even if the terminal is not to be used via an RFID transponder, the RFID reader must be connected to the terminal! 5) Connect the ELO Backpack PC and the ELO display to the power units.
10. COMMISSIONING
The Central Control Panel is already configured in the factory delivery mode so that you only have to put the system into operation. Make sure that the LEHMANN Management Software LMS is installed in your network. As soon as the power supply to the terminal is secured, the system switches on automatically. Do not touch the screen during system startup. You can force the system to shut down by pressing and holding the power button for 12 seconds. 1) When using the device for the first time, select the required operating mode.
In the “Online (LMS)” operating mode, the terminal is connected to the LEHMANN management software LMS via LAN or WLAN. This operating mode is necessary for the ,,LMS Online Self Service”, ,,LMS Virtual Network” and the ,,Pick-up” applications. Follow step 2 if you selected “Online (LMS)”. In the “Offline” operating mode, the terminal is not connected to the LMS and is suitable for the “Locker info” application. If you select this operating mode, the “Locker info” application starts automatically. The following network settings are not necessary.
continue on page 10
9
BDA CENTRAL CONTROL PANEL flat / open frame / 2025-08-19 (GB)
2) Enter the network settings and click “Save”. Then click “Done”. Note: The server URL is the same URL as in the LMS client login window.
Alternatively, the Central Control Panel can be commissioned in online operating mode (LMS) by using the LEHMANN Data Transfer app on an NFC-enabled Android smartphone. To do this, hold the smartphone with the app in front of the RFID reader on the terminal. Enter the network settings in the app. Then hold the smartphone again in front of the RFID reader on the terminal. 3) After the configuration data has been received and processed by the LEHMANN Management Software LMS, the
terminal appears under the ,,Network” menu item in the LMS. Now programme the terminal and configure it. Select the required application for the terminal in the LMS. To do this, click on the menu item “Terminals” and then double-click to select the terminal to be configured. The required application can be selected in the “Application” tab.
4) The selected application starts 10
BDA CENTRAL CONTROL PANEL flat / open frame / 2025-08-19 (GB)
11. ADMIN AREA
To switch to the admin area from an application, tap the German flag in the lower left corner of the display 7 times.
The factory PIN code is: 9080705555
ATTENTION: Please change the factory PIN code immediately. To do this, enter your new PIN code in the PIN
field in the admin area and click on “Save”.
11.1 Admin area for online operating mode
In the admin area of the online operating mode, the network settings for the Central Control Panel can be adjusted at any time. Enter the appropriate settings and click “Save”. Then click “Back” to go to the application. If you click on “Home”, you can select the operating mode. You can access the application via “Back”. You can exit the software using “Exit”. This function is only possible using a separate PIN code. If necessary, the PIN code can be requested from the support department of Lehmann Vertriebsgesellschaft.
continue on page 12
11
BDA CENTRAL CONTROL PANEL flat / open frame / 2025-08-19 (GB)
11.2 Admin area for offline operation mode
The PIN code can be adjusted in the admin area of the offline operating mode. If you click on “Home”, you can select the operating mode. You can access the application via “Back”. You can exit the software using “Exit”. This function is only possible using a separate PIN code. If necessary, the PIN code can be requested from the support department of Lehmann Vertriebsgesellschaft.
11.3 Change PIN code for the admin area
The admin area is protected by a PIN code. It is strongly recommended to change the factory PIN code. To do this, enter your new PIN code in the PIN field in the admin area and click on “Save”. This applies to online and offline operating modes.
12
BDA CENTRAL CONTROL PANEL flat / open frame / 2025-08-19 (GB)
12. APPLICATION: LMS ONLINE SELF SERVICE
This mode can only be used when using networked LEHMANN RFID locks (CAPTOS) with the LEHMANN management software LMS (LMS Online). In this mode, users have the opportunity to select, to manage and to open available lockers on the central control panel. The Central Control Panel must be connected to the LMS via the network. Depending on the lock type, the lock can be opened with an RFID transponder on the terminal and/or directly on the lock.
12.1 Lock configuration in the LEHMANN Management Software LMS
The locks that should be operated via the Central Control Panel require the following configuration in the LMS: · Operating mode: assigned use · Auto Locking: 5 seconds · Push to Open: off
The locks must be grouped together in a lock group in the LMS (menu item in LMS: lock group). This lock group is then assigned to the terminal. To do this, click on “Terminals” under the Network menu item in the LMS. The lock group can be assigned to the terminal in the “Associated” tab. The access technologies (RFID or PIN code) for opening and managing the locks can be defined in the LMS. RFID and PIN code can be selected. This terminal type does not support the 3D camera for facial recognition.
· Click on ,,Terminals” in the LMS menu. · Select the required terminal in the overview and click on ,,Edit”. · Select ,,LMS Online Self Service” under ,,Applications” and click on ,,Edit” · Select the required access technology and click on ,,Save”. · The access technologies are now shown on the display of the terminal.
12.2 General Operation
The user selects the required operating option or holds an RFID transponder in front of the RFID reader at the terminal.
PIN code: You can open and manage a locker with a PIN code. RFID: You can open and manage a locker with a valid RFID transponder. When using transponders, they must be held in front of the RFID reader at the terminal. Hold the transponder in front of the RFID reader until an acknowledgment or further instructions appear on the display. Then remove the transponder from the RFID reader.
continue on page 14
13
BDA CENTRAL CONTROL PANEL flat / open frame / 2025-08-19 (GB)
After selecting the operating option, the user selects his required action.
If the user wants to add a new locker, select “Add locker”. If you want to open a locker that is locked, click on “Open locker”. If you want to change a PIN code or delete a permission, click on “Manage locker”.
12.3 Add locker
If the user selects “Add locker”, the system automatically suggests a locker.
The user can take the suggested locker or select different locker by clicking on one of the two options. If you click on “Choose different locker”, the available lockers are displayed and the user can select. When using an RFID transponder, it must now be held in front of the RFID reader on the terminal according to the instructions. When using a PIN code, a PIN code must be entered and confirmed. The locker is confirmed and you can now open the locker in a separate step.
14
BDA CENTRAL CONTROL PANEL flat / open frame / 2025-08-19 (GB)
12.4 Open locker
To open a locker, the user clicks on “Open locker” in the main menu and selects the respective locker in the overview. When using RFID transponders, the authorized transponder must be held in front of the RFID reader on the terminal. When using a PIN code, the correct PIN code must be entered. The locker opens and locks automatically after 5 seconds. The user pushes the door of the locker in closed position.
12.5 Manage locker
To delete a permission or change a PIN code, click on “Manage locker” in the main menu. Then click on the required action and select the respective locker in the overview. When deleting a permission, the user must complete the process by clicking “Release”.
12.6 Emergency opening
Regardless of whether a locker was locked by using a PIN code or a RFID transponder, an emergency opening can be carried out by using the LEHMANN Management Software LMS. For an emergency opening, select the lock in the LMS and open the lock settings. Under “More options” click on “Open lock”.
12.7 Release of a locker by the admin
In order to release a lock by the admin, the permission for that lock simply needs to be revoked in the LEHMANN Management Software. The lock is then available to all users again.
15
BDA CENTRAL CONTROL PANEL flat / open frame / 2025-08-19 (GB)
13. APPLICATION: LMS VIRTUAL NETWORK
This application can be used together with offline LEHAMNN RFID locks. The locks must be managed in the LEHMANN Management Software LMS. While the Central Control Panel is connected to the LMS directly via the network (LAN or WLAN), the locks are not directly connected to the LMS via the network. Permission changes are sent from the LMS to the Central Control Panel. The authorizations are transferred to the transponders when users hold the transponders in front of the RFID reader at the terminal. The Virtual Network feature is not supported if only the UID of a transponder is processed.
13.1 Lock configuration in the LEHMANN Management Software LMS
There is no specific configuration for the locks required in the LMS for this application. The general configuration of the locks takes place in the LMS. Configuration changes are transferred from the software to the locks via NFC-enabled Android smartphones by using the LEHMANN Data Transfer app. Configuration changes are not transmitted to the locks via transponders. To do this, follow the instructions in the separate manual for the LEHMANN Management Software LMS.
13.2 Transfer of permissions to transponders
Permission changes are carried out in the LEHMANN Management Software. The permission change is automatically transferred to the USB desktop readers and to the connected terminals. Transponders must be programmed in the LEHMANN Management Software LMS. After commissioning the application and establishing the connection between the terminal and LMS, the following view can be seen on the display.
Users must hold their transponders in front of the RFID reader on the terminal, in order to transfer permissions to the transponder. The transponder must be held in front of the RFID reader until an acknowledgment (green tick) or further instructions appear on the display. Then remove the transponder from the RFID reader.
16
BDA CENTRAL CONTROL PANEL flat / open frame / 2025-08-19 (GB)
The permissions for the transponder have been transferred. The transponder can be used on the respective lock(s).
14. APPLICATION: LOCKER INFO
In this application, the number or the name of the previously occupied locker is shown on the terminal display when the transponder is held in front of the RFID reader on the terminal. This application is suitable for both online and offline LEHMANN RFID locks in the “shared use” operating mode. The locks must be managed with the LEHMANN Management Software LMS. The LEHMANN transponder app is currently not supported. The Central Control Panel does not have to be connected to the LMS.
Users must hold their transponder in front of the RFID reader on the terminal, in order to get the information of his used locker on the terminal displayed.
17
BDA CENTRAL CONTROL PANEL flat / open frame / 2025-08-19 (GB)
15. APPLICATION: PICK-UP
15.1 Programming transponders and email addresses
In the LEHMANN Management Software LMS, the email addresses must be created in the transponder settings for the respective transponders.
15.2 Configuring the mail server settings
The settings for the mail server must be made in the Project Settings menu item within the LMS. To do this, click on the “Mail Server” tab.
15.3 Configuring the Pick-up application in the LMS
In the LMS, click on Terminal and Edit. Then click on the ,,Application” tab and select ,,Pick-up”. For further configuration, click on the ,,Edit” button next to ,,Pick-up”. The window opens. Click on the “Edit” button next to Postmen. You can now select one or more transponders that should have the authorization to deposit packages in the lockers. Now select the technology that the recipients should use to open the locker door. RFID, PIN code and QR code are available. The PIN code and QR code are automatically generated by the system and sent to the recipient by email. Then click on ,,Save”. Now select the “Associated” tab under the configuration settings. The available lock groups are displayed in the righthand “Available” window. Mark the required lock group and click on the left arrow. Click on “Save”.
15.4 Operating the terminal with the Pick-up application
15.4.1 Deposit a package To drop off a package, an authorized person clicks on the ,,Package delivery” button. To authorize yourself, you must hold the corresponding transponder in front of the RFID reader on the terminal. After authorization, the recipient can be selected. All people with an email address in the LMS are displayed now. Select the required recipient and then click ,,OK”. The system then suggests an available locker. Click ,,Apply” if the package should be placed in the suggested locker. After a compartment has been selected and ,,OK” has been clicked, an email is automatically sent to the recipient. The selected compartment also opens automatically and the package can be deposited. The locker door simply needs to be pushed shut.
15.4.2 Pick up the package The recipient receives an email with information about the compartment in which a package has been deposited and the technology that can be used to open the compartment. Only the technologies that were selected in the configuration are mentioned in the email. The recipient selects the ,,Pick up” button at the terminal and authenticates himself using the appropriate technology (RFID, PIN code, QR code). The compartment opens automatically and the package can be removed.
18
BDA CENTRAL CONTROL PANEL flat / open frame / 2025-08-19 (GB)
16. DISPOSAL
Dispose of the product according to local regulations and guidelines.
19
BDA CENTRAL CONTROL PANEL flat / open frame / 2025-08-19 (GB)
LEHMANN Vertriebsgesellschaft mbH & Co. KG Postfach 26 20 · D-32383 Minden Fon +49 571 / 50 599-0 · Fax +49 571 /50 599-822 info@lehmann-locks.com · www.lehmann-locks.com DIN EN ISO 9001:2015 zertifiziert
20
BDA CENTRAL CONTROL PANEL flat / open frame / 2025-08-19 (GB)
Documents / Resources
![]() |
Lehmann BDA Central Control Panel [pdf] Instruction Manual 2025-08-19, BDA Central Control Panel, BDA, Central Control Panel, Control Panel, Panel |