legrand 752X70A Automatic Switch With and Without Neutral
Specifications
- Product Name: Valena LIFE/ALLURETM Automatic switch with and without neutral
- Cat. No(s): 7 52X 70A/72A/73A/177A/770A/870A/970A 756373A
- Color: White, Ivory, Aluminium, Black
- Motion sensor options: With or without neutral, 2 or 3 wires
- IP Rating: IP44
Product Usage Instructions
Installation
Ensure the power is switched off before installation. Mount the automatic switch in a recessed box with a minimum depth of 30mm using screw fixing.
Connection
Use a flat 4mm screwdriver to connect the wires. Terminal capacity is 2 x 1.5 mm2 or 1 x 2.5 mm2 with an 8mm stripping length.
Programming
Adjust the time delay potentiometer for the desired delay time between 5 seconds to 30 minutes. Set the light level sensor according to your preference.
Technical Characteristics
- Mechanical characteristics: Impact tests: IK 04, Protection: IP 20 mounted product, IP 40 mounted product with support frame and plate.
- Material characteristics: Mechanism casing: PC, Lens: opalescent white, Cover-plate: ABS.
Overview
USE
- Universal automatic switches, with or without neutral, with infrared detection.
- Allow automatic control of a light source by detection of movement in their surveillance zone.
- Replace use of a traditional mechanical switch.
- Recessed mounting in box depth 30 mm minimum.
- Screw fixing.
RANGE
Description | White | Ivory | Aluminium | Black |
Motion sensor without neutral 2 wires | 7 521 70A/72A/7 70A | 7 522 70A/72A/8 70A | 7 523 70A/72A/9 70A | |
Motion sensor with neutral 3 wires | 7 521 73A | 7 522 73A | 7 523 73A | 7 563 73A |
IP44 Motion sensor without neutral 2 wires | 7 521 77A |
DISMANTLING
DIMENSIONS (mm)
References | A | B | C | D |
7 52X 70A | 74,7 | 74,7 | 47,9 | 19 |
7 52X 72A | 74,7 | 74,7 | 47,5 | 18,6 |
7 52X 73A | 74,7 | 74,7 | 47,9 | 19 |
7 521 77A | 78,2 | 78,2 | 48,7 | 20,9 |
7 527 70A/8 70A/9 70A | 74,7 | 74,7 | 48 | 19 |
7 563 73A | 74,7 | 74,7 | 47,9 | 19 |
CONNECTION
- Type of terminals: with screws
- Terminal capacity: 2 x 1.5 mm2 – 1 x 2.5 mm2
- Stripping length: 8 mm
- Screwdriver: flat 4 mm
DESCRIPTION
TECHNICAL CHARACTERISTICS
General characteristics
Motion detectors with 170° detection angle. Detection range: 8 m max.
Mechanical characteristics
- Impact tests: IK 04
- Protection against solid bodies and liquids:
- IP 20 mounted product
- IP 40 mounted product with support frame and plate
Material characteristics
- Mechanism casing: PC
- Lens: opalescent white
- Cover-plate: ABS
- Couleur : WhiteRAL 9003 painted mat Black RAL 9017 satin finish painted Aluminium
- Plate (complete product): White ABS RAL 9003 polyglass appearance Halogen-free UV-resistant
Self-extinguishing:
- 850°C/30 s for insulating components holding live parts in place
- 650°C/30 s for other insulating components.
Climate characteristics
- Usage temperature: -5°C to +35°C
- Storage temperature: -10°C to +70°C
Electrical characteristics – 2-wire without neutral
- Voltage: 110-240 V~
- Current: 0.63 A max.
- Frequency: 50/60 Hz
- Standby consumption: < 0.010 W
(*) If the load malfunctions, it may be necessary to use bleeder Cat. No. 0 401 49. Important: Take transformer losses into account when calculating the power.
Electrical characteristics – 3-wire with neutral
- Voltage: 110-240 V~
- Current: 8.5 A MAX
- Frequency: 50/60 Hz
- Standby consumption: < 0.015 W
Important: Take transformer losses into account when calculating the power.
Energy characteristics
Stanby consumption for 1000 hours:
- 2- wire without neutral: 0.088 kWh/1000 h
- 3- wire with neutral: 0.131 kWh/1000 h
CLEANING
- Keep the lens clean.
- Surface cleaning with a cloth.
- Do not use: acetone, tar remover, trichlorethylene.
- Maintenance with the following products: Hexane (EN 60669-1), Methylated spirit, Soapy water, Diluted ammonia, Bleach diluted to 10%, Window cleaning products.
Caution: Always test before using other special cleaning products.
STANDARDS AND APPROVALS
Compliance with standards of installation and manufacturing.
Refer to e. catalogue.
FAQ
- Q: What should I do if the load malfunctions?
- A: If the load malfunctions, it may be necessary to use bleeder Cat. No. 0 401 49. Take transformer losses into account when calculating the power.
- Q: What is the standby consumption for 1000 hours?
- A: Standby consumption for 1000 hours is 0.088 kWh/1000 h for 2-wire without neutral and 0.131 kWh/1000 h for 3-wire with neutral.
- Q: Can I use special cleaning products to clean the automatic switch?
- A: Always test before using other special cleaning products to avoid any damage to the product.
Documents / Resources
![]() |
legrand 752X70A Automatic Switch With and Without Neutral [pdf] Owner's Manual 752X70A, 752X72A, 752X73A, 752X77A, 752770A, 752870A, 752970A, 756373A, 752X70A Automatic Switch With and Without Neutral, 752X70A, Automatic Switch With and Without Neutral, Without Neutral |