Specifications

  • Product: Cassettes and blocks for modular panels
  • Compatibility: Modular panels Cat. Nos. 0 321 75/76/77
  • Connector Type: LC connectors to MTP connector
  • Fiber Type: 50/125 m multimode OM3, OM4, OM5; 9/125 m singlemode OS2
  • Polarity: Universal
  • Performance: Ultra performance

Product Usage Instructions

Presentation
MTP high-density cassettes are compatible with MPO and can be installed in modular panels Cat. Nos. 0 321 75/76/77. Slide-in cassettes can be easily removed by pressing from the front or rear, simplifying installation and maintenance.

Cassette and Block Ranges

Slim Cassettes

  • 0 321 68: Slim pre-terminated cassette with 12 multimode OM3 fibers and 12 LC connectors to MTP connector.
  • 0 321 69: Preterminated slim cassette with 12 multimode OM4 fibers and 12 LC connectors to MTP connector.
  • 0 321 70: Preterminated slim cassette with 12 multimode OS2 fibers and 12 LC connectors to MTP connector.

HVSL12
Preterminated slim cassette with 12 multimode OM4 fibers and 12 LC connectors to MTP connector with universal polarity and ultra performance.

PRESENTATION

  • MTP high-density slim cassettes (compatible with MPO)
    For installation in modular panels Cat. Nos. 0 321 75/76/77 and in Zero kit Cat. No. 0 321 03. Each slide-in cassette can be removed individually from the front or rear by simply grasping hold of it. They simplify installation and maintenance.
    Slim cassettes are mounted with their holder (0 321 38). This can take up to 2 cassettes Cat. Nos. 0 321 68/69/70 – 0 322 38 – HVSL12 and up to 2 blanking plates Cat. No. 0 321 39 or 1 cassette + 1 blanking plate.
  • MTP high-density cassettes (compatible with MPO)
    For installation in modular panels Cat. Nos. 0 321 75/76/77. Slide-in cassettes can be removed by simply pressing from the front or rear.
    They simplify installation and maintenance.
  • Pre-equipped cassettes
    For installation in modular panels Cat. Nos. 0 321 75/76/77. Pre-equipped cassettes with fiber optic blocks fitted with 6 or 12 OM3 pigtails supplied. Slide-in cassettes can be removed by simply pressing from the front or rear.
    They simplify installation and maintenance.

Cassette dimensions (mm)

A B C
0 321 38

0 321 68/69/70

HVSL12 – 0 322 38

110.3

100

44

13.6

161

194

0321 41
0321 80/81/82

0321 83/84/85

185
0321 86/87 110 44
0321 42/43/44
0321 45/48/49

0321 59/60

200

legrand-0-321-Series-Cassettes-and-Blocks-for-Modular-Panels- (3)

Cassette weight (g)

Cat. Nos.
0 321 38

0 321 68/69/70 – HVSL12 – 0 322 38

80

100

0321 41/42/43/45/48/49/59/60

0321 80/81/82 0321 83/84/85/86/87

 

195

CASSETTE AND BLOCK RANGES

legrand-0-321-Series-Cassettes-and-Blocks-for-Modular-Panels- (4) legrand-0-321-Series-Cassettes-and-Blocks-for-Modular-Panels- (5) legrand-0-321-Series-Cassettes-and-Blocks-for-Modular-Panels- (6) legrand-0-321-Series-Cassettes-and-Blocks-for-Modular-Panels- (7) legrand-0-321-Series-Cassettes-and-Blocks-for-Modular-Panels- (8) legrand-0-321-Series-Cassettes-and-Blocks-for-Modular-Panels- (9)

CASSETTE TECHNICAL CHARACTERISTICS

  • MTP high density slim cassette (compatible with MPO)
    Singlemode and multimode slim cassettes can be combined in the same holder
    Two 12 FO cassettes per cassette holder for more flexibility.
    Ultra performance cassette, low insertion loss < 0.5 dB. Factory tested and detailed on the test report provided on the cassette.
  • Universal polarity
    MTP high density cassette (compatible with MPO)
    Already equipped with preterminated fibres, directly connectible to female MTP connector with 12 fibres (compatible with MPO).
    Ultra performance cassette, low insertion loss < 0.5 dB. Factory tested and detailed on the test report provided on the cassette.
  • A/C polarity
    Fibre optic cassette to be spliced
    Connectible cassette, supplied with removable pigtail holder, with coiling area. Sold with 2 PG11s
    Takes any modular fibre optic block and MTP high density adaptor

legrand-0-321-Series-Cassettes-and-Blocks-for-Modular-Panels- (10)Material characteristics
Material: polycarbonate IP40

Fitting a cassette

legrand-0-321-Series-Cassettes-and-Blocks-for-Modular-Panels- (11)

Removing a cassette from the frontlegrand-0-321-Series-Cassettes-and-Blocks-for-Modular-Panels- (12)

legrand-0-321-Series-Cassettes-and-Blocks-for-Modular-Panels- (13)

Connecting a pre-terminated cassette legrand-0-321-Series-Cassettes-and-Blocks-for-Modular-Panels- (14)

CONNECTORS

The Legrand core, ultra and quantum connectivity performances are far superior than standard. They provide the following benefits for the user :

  • Wider range of applications
  • More flexibility in the design
  • Energy saving on the active (transceivers)
  • All connectors have a durability of 500 cycles (IEC 61300-2-2)
  • MPO/MTP connectors comply to IEC 61754-7-1
  • LC connectors comply to IEC 61754-20
  • SC connectors comply to IEC 61754-4
  • ST connectors comply to IEC 61754-2

Optical performance

MTP® connectors

Multimode Ultra Performance* Singlemode Ultra Performance*
IL/Master 0.1 dB typical (all fibres)

0.35 dB maximum (single fibre) 2.3

0.1 dB typical (all fibres)

0.35 dB maximum

(single fibre) 1.4

IL Max/Random* 0.35 dB (single fibre) 0.35 dB (single fibre)
Optical return loss 5 > 20 dB > 60 dB (8° angle- polished)
  1. As tested in accordance with ANSI/TIA-455-171 Method D3 / IEC 61300-3-4
  2. As tested in accordance with ANSI/TIA-455-171 Method D1 / IEC 61300-3-4
  3. As tested on 50µm fibres at a wavelength of 850 nm in accordance with IEC 61280-4-1
  4. Complies with IEC 61755-3-31/GRADE B
  5. As tested in accordance with IEC 61300-3-6 and ANSI/TIA-455-107A

Performance is guaranteed only with other components of the same Legrand range (Core, Ultra and Quantum). Mixing ranges or use of components of other brand may lead to a different performance of the system. The uncertainty value for field measurement with LSPM testing using a reference cord defined in ISO/IEC 14763-3 applies to field testing with proposed Legrand testing cords. Refer to the Fiber Optic Testing Guide for Legrand Solutions.

LC, SC, LC APC, SC APC connectors

Optical performance Singlemode Ultra Performance Multimode Ultra Performance
IL Max/Master * 0.15 dB 0.15 dB
IL Max/Random ** *** 0.25 dB 0.2 dB
Typ. IL/Master * 0.12 dB 0.08 dB
Typ. IL/Random ** *** 0.12 dB 0.10 dB
Return loss (UPC/APC) > 55/65 dB > 25 dB

IEC 61300-3-4

IEC 61300-3-34

  • Performance is guaranteed only with other components of the same Legrand range (Core, Ultra and Quantum). Mixing ranges or use of components of another brand may lead to a different performance of the system. The uncertainty value for field measurement with LSPM testing using a reference cord defined in ISO/IEC 14763-3 applies to field testing with proposed Legrand testing cords. Refer to the Fiber Optic Testing Guide for Legrand Solutions.
    Storage and operating temperature: -10°C to +60°C

Production quality control

For MTP :
Optical performance: 100% factory tested
3D endface geometry (interferometry): 100% factory products controlled For LC, SC, LC APC, SC APC :
Optical performance: 100% factory tested.
3D endface Geometry (interferometry): sampling quality control.

FIBRE OPTIC BLOCKS FOR SPLICEABLE CASSETTE

Fibre optic blocks clip directly onto spliceable cassette Cat. No. 0 321 41 and also onto fibre optic drawer Cat. Nos. 0 321 00/01.legrand-0-321-Series-Cassettes-and-Blocks-for-Modular-Panels- (15)

Block dimensions (mm) legrand-0-321-Series-Cassettes-and-Blocks-for-Modular-Panels- (16)

Cat. Nos. A B C
0 321 10/11/12/20/21  

 

 

109

 

 

 

23

33
0 321 13/14/15/16/23/24/25/36/37

HVBL12/24

 

39

0 321 17/27
0 321 18/19/33/34 45

Approximate block weight (g)

Cat. Nos.
0 321 10/11/12/13/14/15/16/17/20/21/23/24/25/27/36/37- HVBL12/24 50
0 321 18/19/33/34 42

MADE-TO-ORDER PRODUCTS

Please contact your local Legrand sales representative

POLARITY

Universal polarity: Cat. Nos. 0 321 59/60-0 321 68/69/70 – HVSL12
Identical cassettes. Cords A to B at both ends – trunk type B,

legrand-0-321-Series-Cassettes-and-Blocks-for-Modular-Panels- (17)

Method A/C: Cat. Nos. 0 321 42/43/44/45 – 0 321 48/49
Identical cassettes. Cords A to B at one end and cords A to A at the other end – trunk type A

legrand-0-321-Series-Cassettes-and-Blocks-for-Modular-Panels- (18)Method A/C: Cat. Nos. 0 321 42/43/44/45 – 0 321 48/49
Identical cassettes. Cords A to B at both ends – trunk type C.

legrand-0-321-Series-Cassettes-and-Blocks-for-Modular-Panels- (19)Method B, single mode/multimode made-to-order product (9 001 26/36)
Different cassettes (B1 and B2). Cords A to B at both ends – trunk type B.

legrand-0-321-Series-Cassettes-and-Blocks-for-Modular-Panels- (20)For singlemode cassettes with polarity B (key-up/key-up feedthrough), the male MTP connector for the cassette is up-angled in accordance with IEC 61754-1-12 and therefore only compatible with standard polarity B female MTP (or MPO) trunks (down-angled). Polarity B trunks available made-to-order

legrand-0-321-Series-Cassettes-and-Blocks-for-Modular-Panels- (1)

Technical data sheet: S000110251EN/04 Updated: 21/08/2024 Created: 07/01/2020

FAQ

  • Q: Can the cassettes be easily removed for maintenance?
    A: Yes, the slide-in cassettes can be removed by simply pressing from the front or rear, facilitating maintenance tasks.
  • Q: What is the compatibility of the cassettes?
    A: The cassettes are compatible with modular panels Cat—nos. 0 321 75/76/77, offering flexibility in installations.
  • Q: Are custom options available?
    A: Yes, custom options are available for adapters, fibers, or polarity types, providing tailored solutions for specific requirements.

Documents / Resources

legrand 0 321 Series Cassettes and Blocks for Modular Panels [pdf] Instruction Manual
0 321 Series Cassettes and Blocks for Modular Panels, 0 321 Series, Cassettes and Blocks for Modular Panels, Blocks for Modular Panels, Modular Panels, Panels

References

Leave a comment

Your email address will not be published. Required fields are marked *