Bypass Door Window Sensor Z-Wave™ 7007
AA-SS-VE-A0
Bypass Door Window Sensor
Quick Start Guide
In The Box
Door/Window sensor
APP Set Up
- Remove the plastic sheet from the battery cabinet. It’s power on now.
- Add sensor
- The sensor is in pairing mode
- The sensor is connected to the gateway
Product Introduction
The Leedarson door window sensor is designed for use with scenes in home automation and security systems, the door window sensor lets you know when doors or windows are opened and can trigger different actions in response to that open action (or close action).
Detection Technology | Hall |
Detective Range | 20mm |
Communication Protocol | Z-Wave |
Radio Frequency | 908.42MHz (US) 868.42MHz (EU) |
Wireless Range | More than 200m outdoors Approximately 30m indoors (depending on building materials) |
Power Source | 3V, CR2 *1 |
Battery Life | 3 years |
Mounting | Screws or 3M Tape |
Operating Temperature | 0°C to 40°C |
Operating Humidity | Up to 85% non-condensing |
Certifications | CE/FCC, Z-Wave |
OTA | Yes |
Dimensions (mm): | 68.4.(L)*24.4(W)*21.5(H) for Main Body 44.4(L)*15(W)*13(H) for Magnetic Part |
Product Installation
This product can be mounted with screws or 3M adhesive tape, install it according to the following step:
- Remove the plastic sheet for isolating the battery from the battery cabinet.
- Use a pin to reset the pinhole switch for 5 seconds to reset the sensor. The sensor will be in pairing status.
- Stick the slim magnet and device onto the door/window, no further than 20 mm from the sensor, fix the device on the door/window by screw or 3M tape.
- The magnet and the main sensor must be less than 20 mm apart. The main sensor must be affixed to the frame and the magnet must be affixed to the door window.
- Should not be mounted on a metal frame.
![]() |
![]() |
Function of action
Trigger |
Description |
Power on |
|
Not On the network: LED slow blinks red 3 times and start SmartStart. | |
SmartStart Inclusion | Add the Door Sensor into the Z-Wave network via SmartStart:
Note: The user should follow the procedure in the section below if the controller does not support SmartStart inclusion. |
Short press Z-Button one time
|
Add the Door Sensor into the Z-Wave network:
Remove Door Sensor from a Z-Wave network:
|
Short press the Z- button three times | On the network: Send Wake up a notification, and LED will fast blink green during sending data. |
Not on the network: NOP. | |
Press and hold Z-Button for more than 5 seconds | Reset Door Sensor to factory default. LED will blink red faster and faster within 5 seconds and then keep solid red until the button is released. The device will reset itself to factory default by sending a “Device Reset Locally Notification” to the gateway when the button is released. Note: Please use this procedure only when the network primary controller is missing or otherwise inoperable. |
Short press the Bypass-Button | Only on the network: The door Sensor will enter Bypass mode for 5 minutes. Bypass mode: When the bypass button is pressed, the first “open door event” will not be triggered and the first “close door event” will clear the bypass mode. |
This product can be operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers. All mains operated nodes within the network will act as repeaters regardless of vendor to increase the reliability of the network.
This device supports SmartStart inclusion and can be added to a network by scanning the QR Code on the product.
Quick Response Code (QR Code):
The first 16 bytes of the ECDH Public Key and sometimes additional information is encoded into a QR Code graphic. When referred to in this document, “DSK” applies to the Full DSK, the combination of Full DSK and QR Code, or the combination of Pin Code and QR Code. Please refer to the below diagram. the QR code can be found on the bottom of the sensor” or ” The DSK may be located on the back of the packaging.
Safety Information
Battery Safety Information:
- This product contains a coin/button cell battery. If the coin/button cell battery is swallowed, it can cause severe internal burns in just 2 hours and can lead to death. Keep away from babies and small children at all times.
- If the battery is swallowed or placed inside any part of the body, immediately seek medical help.
- Risk of explosion if the battery is replaced by an incorrect type.
- Dispose of used battery promptly.
IMPORTANT: Do not expose yourself to rain. Install the product at least 3 ft. from the door for optimum performance.
This alarm contains small parts and is not suitable for children. Periodically check the condition of the batteries.
Disposal and Recycling Information:
Correct Disposal of this product. This marking indicates that this product should not be disposed of with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased.
They can take this product for environmentally safe recycling.
Maintenance
- f need to clean the sensor, please use a soft cloth with a little alcohol to wipe it after you cut off the power.
- This product is just for indoor use only.
- Should be affixed indoors and away from sources of moisture.
- This product has a low voltage detection reminder. When the battery voltage is in low status, the sensor will give out a low battery signal to the gateway.
- Replace the battery timely on low battery warning to ensure the sensor works properly. Please use battery model CR2 only.
Caution:
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Hereby, Corporation declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU
Special Rule Of Each Command Class
Parameter | Value |
Z-Wave Plus Version | 0x02 |
Role Type | 0x06 (ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_SLEEPING_REPOR TING) |
Node Type | 0x00 (ZWAVEPLUS_INFO_REPORT_NODE_TYPE_ZWAVEPLUS_NODE) |
Installer Icon Type | 0x0C06 (ICON_TYPE_SPECIFIC_SENSOR_NOTIFICATION_ACCESS_CONTROL) |
User Icon Type | 0x0C06 (ICON_TYPE_SPECIFIC_SENSOR_NOTIFICATION_ACCESS_CONTROL) |
Z-Wave Plus ™ Info Report Command Class
Association Command Class
Door Sensor supports 2 association groups and a max of 5 nodes for each group.
Grouping Identifier |
Max Node |
Send Commands |
Group 1 | 0x05 | 2. Notification Report. The sensor will send a Notification Report when the supported event is triggered. 3. Sensor Multilevel Report. 4. Sensor will send Sensor Multilevel Report in the time set by configuration parameter 0x21/Power on will trigger Sensor Multilevel Report. 5. Battery Report. Power on or the battery level is low 6. Central Scene Notification. The bypass button is pressed 7. Device Reset Locally. Z-Button is pressed and held for more than 5 seconds |
Group 2 | 0x05 | 1. Basic Set Sensor will send Basic Set when the sensor body and magnet are removed or combined. |
Association Group Info Command Class
Association Group Info
Grouping identifier | Group Name | Profile MS | Profile LS |
1 | Lifeline | 0x00 | 0x01 |
2 | On/Off control | 0x71 | 0x06 |
Association Group Command-List
Group 1 | Command List Support |
Command Class | COMMAND_CLASS_NOTIFICATION_V8(0x71) |
Command | NOTIFICATION_REPORT_V8(0x05) |
Command Class | COMMAND_CLASS_BATTERY(0x80) |
Command | BATTERY_REPORT(0x03) |
Command Class | COMMAND_CLASS_DEVICE_RESET_LOCALLY(0x5A) |
Command | DEVICE_RESET_LOCALLY_NOTIFICATION(0x01) |
Command Class | COMMAND_CLASS_SENSOR_MULTILEVEL_V5(0x31) |
Command | SENSOR_MULTILEVEL_REPORT(0X05) |
Command Class | COMMAND_CLASS_CENTRAL_SCENE_V3(0x5B) |
Command | CENTRAL_SCENE_SUPPORTED_NOTIFICATION_V3(0x03) |
Group 2 | Command List Support |
Command Class | COMMAND_CLASS_BASIC(0x20) |
Command | BASIC_SET(0x01) |
Notification Commands
Notification Type |
Notification Event |
HOME_SECURITY (0x07) | (0x00) Previous Events cleared (0X03) TAMPERING_COVERING_REMOVED |
ACCESS_CONTROL (0x06) | (0x16) WINDOW_DOOR_IS_OPEN (0x17) WINDOW_DOOR_IS_CLOSE |
POWER_MANAGEMENT (0x08) | (0x0A) REPLACE_BATTERY_SOON 10 (0x0B) REPLACE_BATTERY_NOW 11 (0x00) Previous Events cleared |
SYSTEM (0x09) | (0x09) Digital input high state |
How to trigger these different notifications;
Home Security:
Tampering_Covering_Removed (0x03): the tamper button back to the main body is released.
Previous Events cleared (0x00): the tamper button back the main body is pressed.
Access Control:
The door is open (0x16): the separation of the main body and the magnet.
The door is closed (0x17): the combination of the main body and the magnet.
Power Management:
REPLACE_BATTERY_SOON (0x0A): When the Door Sensor first time detects the battery level is less than/equal to the value set by configuration parameter 0x0A.
REPLACE_BATTERY_NOW (0x0B): When the Door Sensor first time detects battery level is less than/equal 5%.
Previous Events cleared (0x00): When the battery is replaced by a new one.
SYSTEM:
Digital input high state: When a powerful magnet is put on the Door Sensor.
PS: This is used to notify the user that may be a thief who intends to destroy the Intruder alarm system.
5.4 Wake Up Interval Capabilities Report CC
Parameter | Value |
WAKEUP_PAR_DEFAULT_SLEEP_TIME | 0x5460 |
WAKEUP_PAR_MAX_SLEEP_TIME | 0x015180 |
WAKEUP_PAR_MIN_SLEEP_TIME | 0x14 |
WAKEUP_PAR_SLEEP_STEP | 0x14 |
5.5 Manufacturer Specific Report
Parameter | Value |
Manufacturer ID 1 | 0x03 |
Manufacturer ID 2 | 0x00 |
Product Type ID 1 | 0x03 |
Product Type ID 2 | 0x00 |
Product ID 1 | 0x00 |
Product ID 2 | 0x41 |
5.6 Configuration Set Command Class
5.6.1 Command Format
7 | 6 | 5 | 4 | 3 | 2 | 1 |
0 |
Command Class = COMMAND_CLASS_CONFIGURATION | |||||||
Command = CONFIGURATION SET | |||||||
Parameter Number | |||||||
Default |
Reserved |
Size |
|||||
Configuration Value 1(MSB) | |||||||
Configuration Value 2 | |||||||
…… | |||||||
Configuration Value n(LSB) |
5.7 Central Scene (8 bit)
Command | Key Attribute | number |
Central Scene( press central button ) |
0x00(press 1 time) | 0x01 |
0x01(release) | 0x01 | |
0x02(held) | 0x01 | |
0x03(press 2 times) | 0x01 |
5.9 Parameter Number Definitions (8 bit)
Parameter Number |
Description | DefaultValue(dec ) |
Size |
3×01 | 7210Fterge Set the range about magnetic field Range: 0-the range of parameter 0x02 is 0x00000001-0x00004B00, the range of parameter 0x03 is x00000001-0x00002300. 1- the range of parameter 0x02 is 0x00000001-0x0002EE00, the range of parameter 0x03 is x00000001-0x00015E00. |
0 | I |
)x02 | 72100P Set the average magnetic field in ut Range: 0x00000001-0x00004B00 or 0x00000001-0x0002EE00 |
640 | 4 |
3×03 | 7210PolHyst Set the offset about magnetic field Range: 0x00000001-0x00002300 or 0x00000001-0x00015E00 |
200 | 4 |
DxOA | LoweatRecent This parameter defines a battery level as the “low battery. Range: Ox05-0x32 |
10 | |
0x0E | BasicEnable Enable/Disable BASIC SET command 0 – Disable. 1 – Enable. |
0 | 1 |
0x0F | BasicReverse The door Sensor reverses its value of BASIC SET when the magnet is triggered. 0 -Send BASIC SET VALUE = OxFF/Ox00 to nodes associated with group 2 when the door is opened/closed. 1 -Send BASIC SET VALUE = 0/255 to nodes associated with group 2 when the door is opened/closed. |
0 | 1 |
3×20 | Bypass Enable/Disable Bypass mode 0 – Enable. 1 – Disable. |
0 | 1 |
0x21 | temp The interval time the Door Sensor reports the Multilevel Sensor Report to the association group1 in minutes. 0x0F-0xFF |
15 | 1 |
0xFE | LockConfig Enable/Disable configuration set 0 – Enable. 1 – Disable. |
0 | 1 |
Name |
Info | Parameter Number | Default Value(dec) | Max Value(dec) | Min Value(dec) | Size | Read Only | Format |
Altering capability |
7210Th: wage | 7210RangeSet | 0x01 | 0 | 1 | 0 | 1 | No read-onlY | Unsigned
integer |
true |
72100P | 72100PSet | 0x02 | 640 | 19200 Or
192000 |
1 | 4 | No read-only | Unsigned
integer |
true |
Neopost | 7210PolHystSe t | 0x03 | 200 | 8960
Or 89600 |
1 | 4 | No read-only | Unsigned
integer |
true |
Lowa(Percent | LowBatAlarm | Ox0A | 10 | S | 5 | 1 | No read-only | Unsigned
integer |
true |
BasicEnable | SendBasic | Ox0E | 0 | 1 | 0 | 1 | No read-onlY | Unsigned
integer |
true |
Basleteverse | BasicValue | OxOF | 0 | 1 | 0 | 1 | No read-onlY | Unsigned
integer |
true |
Bypass | BypassSet | 0x20 | 0 | 1 | 0 | 1 | No read-only | Unsigned
integer |
true |
temp | TemperatureInt o | 0x21 | 15 | 255 | 15 | 1 | No read-only | Unsigned
integer |
true |
LodcCoring | LockConfigSet | OxFE | 0 | 1 | 0 | 1 | No read-onlY | Unsigned
integer |
true |